Measurement of the Conductivity of Skull, Temporarily Removed During Epilepsy Surgery

The conductivity of the human skull plays an important role in source localization of brain activity, because it is low as compared to other tissues in the head. The value usually taken for the conductivity of skull is questionable. In a carefully chosen procedure, in which sterility, a stable temperature, and relative humidity were guaranteed, we measured the (lumped, homogeneous) conductivity of the skull in five patients undergoing epilepsy surgery, using an extended four-point method. Twenty-eight current configurations were used, in each of which the potential due to an applied current was measured. A finite difference model, incorporating the geometry of the skull and the electrode locations, derived from CT data, was used to mimic the measurements. The conductivity values found were ranging from 32 mS/m to 80 mS/m, which is much higher than the values reported in other studies. Causes for these higher conductivity values are discussed.

[1]  D. A. Driscoll,et al.  Current Distribution in the Brain From Surface Electrodes , 1968, Anesthesia and analgesia.

[2]  D. A. Driscoll,et al.  EEG electrode sensitivity--an application of reciprocity. , 1969, IEEE transactions on bio-medical engineering.

[3]  K. Foster,et al.  Dielectric Properties of Fluid-Saturated Bone - The Effect of Variation in Conductivity of Immersion Fluid , 1984, IEEE Transactions on Biomedical Engineering.

[4]  S. Saha,et al.  Electric and dielectric properties of wet human cortical bone as a function of frequency , 1992, IEEE Transactions on Biomedical Engineering.

[5]  R Hoekema,et al.  Multigrid solution of the potential field in modeling electrical nerve stimulation. , 1998, Computers and biomedical research, an international journal.

[6]  G. Huiskamp,et al.  The need for correct realistic geometry in the inverse EEG problem , 1999, IEEE Transactions on Biomedical Engineering.

[7]  Thom F. Oostendorp,et al.  The conductivity of the human skull: results of in vivo and in vitro measurements , 2000, IEEE Transactions on Biomedical Engineering.

[8]  J C de Munck,et al.  The application of electrical impedance tomography to reduce systematic errors in the EEG inverse problem - a simulation study , 2000, Physiological measurement.

[9]  R Stokking,et al.  Registration, segmentation, and visualization of multimodal brain images. , 2001, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[10]  W. Sutherling,et al.  Conductivities of Three-Layer Live Human Skull , 2004, Brain Topography.

[11]  W. Sutherling,et al.  Conductivities of Three-Layer Human Skull , 2004, Brain Topography.

[12]  S. K. Law,et al.  Thickness and resistivity variations over the upper surface of the human skull , 2005, Brain Topography.

[13]  J. A. Albright,et al.  Factors affecting the measurement of bone impedance , 2006, Medical and Biological Engineering and Computing.