Computer-assisted liver tumor surgery using a novel semiautomatic and a hybrid semiautomatic segmentation algorithm

Abstract We developed a medical image segmentation and preoperative planning application which implements a semiautomatic and a hybrid semiautomatic liver segmentation algorithm. The aim of this study was to evaluate the feasibility of computer-assisted liver tumor surgery using these algorithms which are based on thresholding by pixel intensity value from initial seed points. A random sample of 12 patients undergoing elective high-risk hepatectomies at our institution was prospectively selected to undergo computer-assisted surgery using our algorithms (June 2013–July 2014). Quantitative and qualitative evaluation was performed. The average computer analysis time (segmentation, resection planning, volumetry, visualization) was 45 min/dataset. The runtime for the semiautomatic algorithm was <0.2 s/slice. Liver volumetric segmentation using the hybrid method was achieved in 12.9 s/dataset (SD ± 6.14). Mean similarity index was 96.2 % (SD ± 1.6). The future liver remnant volume calculated by the application showed a correlation of 0.99 to that calculated using manual boundary tracing. The 3D liver models and the virtual liver resections had an acceptable coincidence with the real intraoperative findings. The patient-specific 3D models produced using our semiautomatic and hybrid semiautomatic segmentation algorithms proved to be accurate for the preoperative planning in liver tumor surgery and effectively enhanced the intraoperative medical image guidance.

[1]  K. Do,et al.  Standardized measurement of the future liver remnant prior to extended liver resection: methodology and clinical associations. , 2000, Surgery.

[2]  Benoit M. Dawant,et al.  Semi-automatic Segmentation of the Liver and its Evaluation on the MICCAI 2007 Grand Challenge Data Set , 2007 .

[3]  Ilona H. Hollander,et al.  Virtual Liver Resection and Volumetric Analysis of the Future Liver Remnant using Open Source Image Processing Software , 2010, World Journal of Surgery.

[4]  Yoshikazu Maruyama,et al.  Planning of anatomical liver segmentectomy and subsegmentectomy with 3-dimensional simulation software. , 2013, American journal of surgery.

[5]  Alban Denys,et al.  Total and segmental liver volume variations: implications for liver surgery. , 2004, Surgery.

[6]  Guido Gerig,et al.  User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability , 2006, NeuroImage.

[7]  Martin Styner,et al.  Comparison and Evaluation of Methods for Liver Segmentation From CT Datasets , 2009, IEEE Transactions on Medical Imaging.

[8]  Luc Soler,et al.  Real-time 3D image reconstruction guidance in liver resection surgery. , 2014, Hepatobiliary surgery and nutrition.

[9]  William C Chapman,et al.  Novel three-dimensional imaging technique improves the accuracy of hepatic volumetric assessment. , 2011, HPB : the official journal of the International Hepato Pancreato Biliary Association.

[10]  Xiaopeng Yang,et al.  A hybrid semi-automatic method for liver segmentation based on level-set methods using multiple seed points , 2014, Comput. Methods Programs Biomed..

[11]  Timo Kohlberger,et al.  Evaluating Segmentation Error without Ground Truth , 2012, MICCAI.

[12]  Daniel Rueckert,et al.  Corrigendum to “An evaluation of four automatic methods of segmenting the subcortical structures in the brain” [NeuroImage 47 (2009) 1435–1447] , 2010, NeuroImage.

[13]  E. Rummeny,et al.  Rapid Assessment of Liver Volumetry by a Novel Automated Segmentation Algorithm , 2013, Journal of computer assisted tomography.

[14]  Shunsuke Ohshima,et al.  Volume analyzer SYNAPSE VINCENT for liver analysis , 2014, Journal of hepato-biliary-pancreatic sciences.

[15]  Michael I. Miga,et al.  Model-Assisted Image-Guided Liver Surgery Using Sparse Intraoperative Data , 2012 .

[16]  Daniel Rueckert,et al.  An evaluation of four automatic methods of segmenting the subcortical structures in the brain , 2009, NeuroImage.

[17]  Stephen J. Wigmore,et al.  Liver Volumetry Plug and Play: Do It Yourself with ImageJ , 2007, World Journal of Surgery.

[18]  Milan Sonka,et al.  3D Slicer as an image computing platform for the Quantitative Imaging Network. , 2012, Magnetic resonance imaging.

[19]  P Hermanek,et al.  [Diagnosis and treatment of colorectal liver metastases - workflow]. , 2008, Zentralblatt fur Chirurgie.