Correction of Heart Motion Due to Respiration in Clinical Myocardial Perfusion SPECT Scans Using Respiratory Gating

Several studies have described nonuniform blurring of myocardial perfusion imaging (MPI) due to respiration. This article describes a technique for correcting the respiration effect and assesses its effectiveness in clinical studies. Methods: Simulated phantoms, physical phantoms, and patient scans were used in this study. A heart phantom, which oscillated back and forth, was used to simulate respiration. The motion was measured on a γ-camera supporting list-mode functionality synchronized with an external respiratory strap or resistor sensor. Eight clinical scans were performed using a 1-d 99mTc-sestamibi protocol while recording the respiratory signal. The list-mode capability along with the strap or sensor signals was used to generate respiratory bin projection sets. A segmentation process was used to detect the shift between the respiratory bins. This shift was further projected to the acquired projection images for correction of the respiratory motion. The process was applied to the phantom and patient studies, and the rate of success of the correction was assessed using the conventional bull's eye maps. Results: The algorithm provided a good correction for the phantom studies. The shift after the correction, measured by a fitted ellipsoid, was <1 mm in the axial direction. The average motion due to respiration in the clinical studies was 9.1 mm in the axial direction. The average shift between the respiratory phases was reduced to 0.5 mm after correction. The maximal change in the bull's eye map for the clinical scans after the correction was 6%, with a mean of 3.75%. The postcorrection clinical summed perfusion images were more uniform, consistent, and, for some patients, clinically significant when compared with the images before correction for respiration. Conclusion: Myocardial motion generated by respiration during MPI SPECT affects perfusion image quality and accuracy. Motion introduced by respiration can be corrected using the proposed method. The degree of correction depends on the patient respiratory pattern and can be of clinical significance in certain cases.

[1]  T Kumazaki,et al.  Development of respiratory gated myocardial SPECT system , 1999, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[2]  W. Segars,et al.  Study of the efficacy of respiratory gating in myocardial SPECT using the new 4-D NCAT phantom , 2001 .

[3]  Klaus Schafers,et al.  Respiratory gating of cardiac PET data in list-mode acquisition , 2006, European Journal of Nuclear Medicine and Molecular Imaging.

[4]  G. J. Klein,et al.  Real-time system for respiratory-cardiac gating in positron tomography , 1997 .

[5]  Michael A. King,et al.  Correction of the Respiratory Motion of the Heart by Tracking of the Center of Mass of Thresholded Projections: A Simulation Study Using the Dynamic MCAT Phantom. , 2001 .

[6]  L. Barnden,et al.  Effect of mechanically simulated diaphragmatic respiratory motion on myocardial SPECT processed with and without attenuation correction. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  Michael A. King,et al.  A study of possible causes of artifactual decreases in the left ventricular apex with SPECT cardiac perfusion imaging , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[8]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association , 2002, The international journal of cardiovascular imaging.

[9]  P.M. Bloomfield,et al.  Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET , 2005, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[10]  G. J. Klein,et al.  Four-dimensional affine registration models for respiratory-gated PET , 2001 .

[11]  S. Riederer,et al.  Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.

[12]  Guang-Zhong Yang,et al.  Predictive cardiac motion modeling and correction with partial least squares regression , 2004, IEEE Transactions on Medical Imaging.

[13]  Benjamin M. W. Tsui,et al.  Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms , 1999 .

[14]  David S. Lalush,et al.  Effects of upward creep and respiratory motion in myocardial SPECT , 2000 .

[15]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. , 2002, Circulation.

[16]  G. J. Klein,et al.  Automated 3-D segmentation of respiratory-gated PET transmission images , 1997 .