Response time of thermal flow sensors with air as fluid

Abstract Due to their fast response time miniaturized thermal flow sensors can be applied well for the measurement of instationary gas flow. For some applications, the response time of the sensor must be known with high accuracy. We investigated three methods for response time determination with air: a jump of temperature induced by electric heating, a gas velocity step made by a membrane burst and acoustic phase shifts between sound velocity and sound pressure (standing and traveling waves). The measurements have shown that the response time of thermal flow sensors is a function of flow velocity. For stagnant flow, the thermal response time is about 4.5 ms for our thermal flow sensors. With increasing flow from the heater to the thermopiles, the heat transfer rises. Thus, the response time is faster and decreases to about 1 ms.

[1]  Hermann Sandmaier,et al.  Thermal Flow Sensors for Very Small Flow Rate , 2001 .

[2]  W. Lang,et al.  Temperature stability improvement of thin-film thermopiles by implementation of a diffusion barrier of TiN , 2009, 2009 IEEE Sensors.

[3]  G Kaltsas,et al.  Novel C-MOS compatible monolithic silicon gas flow sensor with porous silicon thermal isolation , 1999 .

[4]  Gerald Urban,et al.  Development of miniaturized semiconductor flow sensors , 2003 .

[5]  Yasuroh Iriye,et al.  Experimental and theoretical study of an on-wall in-tube flexible thermal sensor , 2007 .

[6]  W. Benecke,et al.  Miniaturised Thermal Flow Sensors for Rough Environments , 2006, 19th IEEE International Conference on Micro Electro Mechanical Systems.

[7]  Kofi A. A. Makinwa,et al.  A wind-sensor interface using thermal sigma delta modulation techniques , 2001 .

[8]  Walter Lang,et al.  A Temperature Compensation Circuit for Thermal Flow Sensors Operated in Constant-Temperature-Difference Mode , 2010, IEEE Transactions on Instrumentation and Measurement.

[9]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[10]  Walter Lang,et al.  Thermal flow sensor for liquids and gases based on combinations of two principles , 1999 .

[11]  Walter Lang Heat transport from a chip , 1990 .

[12]  The temperature dependence of the time constants of thermoelectrical infrared detectors derived from their digitized step function response , 1991 .

[13]  H. Glosch,et al.  Thermal flow sensor for liquids and gases , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[14]  Walter Lang,et al.  A high-temperature thermopile fabrication process for thermal flow sensors , 2006 .

[15]  W. J. Fleming,et al.  Overview of automotive sensors , 2001 .

[16]  Imin Kao,et al.  Intelligent diagnosis of mechanical-pneumatic systems using miniaturized sensors , 2006, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.