Glove-based sensors for multimodal monitoring of natural sweat

Functionalized glove sensors allow natural sweat analysis without requiring exercise or iontophoretic stimulation. Sweat sensors targeting exercise or chemically induced sweat have shown promise for noninvasive health monitoring. Natural thermoregulatory sweat is an attractive alternative as it can be accessed during routine and sedentary activity without impeding user lifestyles and potentially preserves correlations between sweat and blood biomarkers. We present simple glove-based sensors to accumulate natural sweat with minimal evaporation, capitalizing on high sweat gland densities to collect hundreds of microliters in just 30 min without active sweat stimulation. Sensing electrodes are patterned on nitrile gloves and finger cots for in situ detection of diverse biomarkers, including electrolytes and xenobiotics, and multiple gloves or cots are worn in sequence to track overarching analyte dynamics. Direct integration of sensors into gloves represents a simple and low-overhead scheme for natural sweat analysis, enabling sweat-based physiological monitoring to become practical and routine without requiring highly complex or miniaturized components for analyte collection and signal transduction.

[1]  Gyoujin Cho,et al.  Methylxanthine Drug Monitoring with Wearable Sweat Sensors , 2018, Advanced materials.

[2]  Jason Heikenfeld,et al.  Enhancing glucose flux into sweat by increasing paracellular permeability of the sweat gland , 2018, PloS one.

[3]  Joseph Wang,et al.  Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System , 2016 .

[4]  Joseph Wang,et al.  Wearable Electrochemical Sensors and Biosensors: A Review , 2013 .

[5]  J Heikenfeld,et al.  Complete validation of a continuous and blood-correlated sweat biosensing device with integrated sweat stimulation. , 2018, Lab on a chip.

[6]  Robert C. Wolpert,et al.  A Review of the , 1985 .

[7]  M. Buono,et al.  Sweat Ethanol Concentrations are Highly Correlated with Co‐Existing Blood Values in Humans , 1999, Experimental physiology.

[8]  J B SHIELDS,et al.  The excretion of ascorbic acid and dehydroascorbic acid in sweat and urine under different environmental conditions. , 1945, The Journal of biological chemistry.

[9]  Phillip Won,et al.  A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat , 2016, Science Translational Medicine.

[10]  J. Cohn,et al.  The excretion of trace metals in human sweat. , 1978, Annals of clinical and laboratory science.

[11]  J. Weiner,et al.  The regional distribution of sweating , 1945, The Journal of physiology.

[12]  Sam Emaminejad,et al.  Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis , 2016, Nature.

[13]  Stephen M Hewitt,et al.  Vitamin C Pharmacokinetics: Implications for Oral and Intravenous Use , 2004, Annals of Internal Medicine.

[14]  S. Galloway,et al.  Effect of induced metabolic alkalosis on sweat composition in men. , 2002, Acta physiologica Scandinavica.

[15]  J A Downey,et al.  SWEATING‐PHYSIOLOGY AND PATHOPHYSIOLOGY * , 1976, The Australasian journal of dermatology.

[16]  John A. Rogers,et al.  Passive sweat collection and colorimetric analysis of biomarkers relevant to kidney disorders using a soft microfluidic system. , 2019, Lab on a chip.

[17]  Jayoung Kim,et al.  Wearable biosensors for healthcare monitoring , 2019, Nature Biotechnology.

[18]  S. Lacour,et al.  Stretchable gold conductors embedded in PDMS and patterned by photolithography: fabrication and electromechanical characterization , 2010 .

[19]  Sigurd Wagner,et al.  Mechanisms of reversible stretchability of thin metal films on elastomeric substrates , 2006 .

[20]  Tuomas Happonen,et al.  Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat , 2019, Science Advances.

[21]  Tuomas Happonen,et al.  Porous Enzymatic Membrane for Nanotextured Glucose Sweat Sensors with High Stability toward Reliable Noninvasive Health Monitoring , 2019, ECS Meeting Abstracts.

[22]  Min-Chieh Chuang,et al.  Flexible thick-film glucose biosensor: influence of mechanical bending on the performance. , 2010, Talanta.

[23]  Ali Javey,et al.  Wearable sweat sensors , 2018 .

[24]  Hui Zhang,et al.  The skin's role in human thermoregulation and comfort , 2006 .

[25]  Sam Emaminejad,et al.  Natural Perspiration Sampling and in Situ Electrochemical Analysis with Hydrogel Micropatches for User-Identifiable and Wireless Chemo/Biosensing. , 2019, ACS sensors.

[26]  Jeffrey T La Belle,et al.  Flexible Thick-Film Electrochemical Sensors: Impact of Mechanical Bending and Stress on the Electrochemical Behavior. , 2009, Sensors and actuators. B, Chemical.

[27]  M D Fisher,et al.  Biomechanical performance of powder-free examination gloves. , 1999, The Journal of emergency medicine.

[28]  J Heikenfeld,et al.  The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications. , 2015, Biomicrofluidics.

[29]  W. Hsu,et al.  Neural control of sweat secretion: a review , 2018, The British journal of dermatology.

[30]  G TASHIRO,et al.  A bromphenol blue method for visualizing sweat at the openings of the sweat ducts. , 1961, The Journal of investigative dermatology.

[31]  Jason Heikenfeld,et al.  Integrated sudomotor axon reflex sweat stimulation for continuous sweat analyte analysis with individuals at rest. , 2017, Lab on a chip.

[32]  Zhiyong Fan,et al.  A Wearable Sweat Band for Noninvasive Levodopa Monitoring. , 2019, Nano letters.

[33]  Thomas Mammone,et al.  Gender-linked differences in human skin. , 2009, Journal of dermatological science.

[34]  Jeonghyun Kim,et al.  Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat , 2019, Science Advances.

[35]  Sam Emaminejad,et al.  Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform , 2017, Proceedings of the National Academy of Sciences.

[36]  J M Pingarrón,et al.  A novel non-invasive electrochemical biosensing device for in situ determination of the alcohol content in blood by monitoring ethanol in sweat. , 2014, Analytica chimica acta.

[37]  Wei Gao,et al.  Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids , 2016 .

[38]  Glen P Kenny,et al.  Modified iodine-paper technique for the standardized determination of sweat gland activation. , 2012, Journal of applied physiology.

[39]  N. Taylor,et al.  Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans , 2013, Extreme Physiology & Medicine.

[40]  Dermot Diamond,et al.  A wearable patch for continuous monitoring of sweat electrolytes during exertion. , 2018, Lab on a chip.

[41]  Sam Emaminejad,et al.  A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca(2+) and pH. , 2016, ACS nano.

[42]  Wei Gao,et al.  A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat , 2019, Nature Biotechnology.

[43]  Shalini Prasad,et al.  Simultaneous lancet-free monitoring of alcohol and glucose from low-volumes of perspired human sweat , 2018, Scientific Reports.

[44]  Alan S. Campbell,et al.  Epidermal Microfluidic Electrochemical Detection System: Enhanced Sweat Sampling and Metabolite Detection. , 2017, ACS sensors.

[45]  Hye Rim Cho,et al.  Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module , 2017, Science Advances.

[46]  Benjamin A. Katchman,et al.  Accessing analytes in biofluids for peripheral biochemical monitoring , 2019, Nature Biotechnology.

[47]  J. Weiner,et al.  Excitation and depression of eccrine sweat glands by acetylcholine, acetyl‐β‐methylcholine and adrenaline , 1959, The Journal of physiology.

[48]  Jason Heikenfeld,et al.  Prolonged and localized sweat stimulation by iontophoretic delivery of the slowly-metabolized cholinergic agent carbachol. , 2018, Journal of dermatological science.

[49]  William Bierman,et al.  ACID-BASE BALANCE IN SWEAT , 1932 .