Age-related changes in trabecular bone microdamage initiation.

With age, alterations occurring in bone quality, quantity, and microarchitecture affect the resistance of trabecular bone to local failure. The clinical implications of these changes are evident by the observed exponential increase in fracture incidence with age. Although age-related development of skeletal fragility is well established, it is unclear how the local failure properties of bone change with age. We previously reported a specimen-specific technique to assess microstructural stresses and strains associated with microdamage initiation but did not assess age-related changes. In this study, we compared younger (average age 2 years) and older (average age 10 years) bovine trabecular bone to evaluate how alterations in bovine bone quantity and quality with age affect the local mechanical environment associated with microdamage formation. The results show strong positive correlations between microdamage and local stresses and strains for both younger and older bovine trabecular bone. Correlation strength was slightly improved (<8%) for some parameters by incorporating heterogeneous local material properties based on mineral density into the finite element models. Within individual trabeculae, average stresses and strains were significantly higher in microdamaged trabeculae compared to randomly selected undamaged trabeculae, regardless of age. However, damaged trabeculae in older bone were found to have higher stresses and lower strains than those from younger bone. Corresponding differences in mineral density, microarchitecture, and FEM-determined local material properties were also observed between the two groups. Taken together, these data suggest marked age-related changes in the mechanics of microdamage initiation at the trabecular level. The combined experimental, computational, and histochemical approaches used in this study provide an improved understanding of microdamage initiation and bone quality.

[1]  R. Guldberg,et al.  Trabecular bone microdamage and microstructural stresses under uniaxial compression. , 2005, Journal of biomechanics.

[2]  F. O'Brien,et al.  An improved labelling technique for monitoring microcrack growth in compact bone. , 2002, Journal of biomechanics.

[3]  L. Melton,et al.  Epidemiology of hip fractures: implications of the exponential increase with age. , 1996, Bone.

[4]  A. Boskey,et al.  FTIR Microspectroscopic Analysis of Normal Human Cortical and Trabecular Bone , 1997, Calcified Tissue International.

[5]  Fergal J O'Brien,et al.  Microcrack accumulation at different intervals during fatigue testing of compact bone. , 2003, Journal of biomechanics.

[6]  F. Linde,et al.  The effect of different storage methods on the mechanical properties of trabecular bone. , 1993, Journal of biomechanics.

[7]  A. Boskey,et al.  FTIR Microspectroscopic Analysis of Human Iliac Crest Biopsies from Untreated Osteoporotic Bone , 1997, Calcified Tissue International.

[8]  G. Niebur,et al.  Convergence behavior of high-resolution finite element models of trabecular bone. , 1999, Journal of biomechanical engineering.

[9]  A. Boskey Bone mineral crystal size , 2003, Osteoporosis International.

[10]  A. Boskey,et al.  Bone Fragility and Collagen Cross‐Links , 2004, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[11]  A. Bailey,et al.  Age-Related Changes in the Biochemical Properties of Human Cancellous Bone Collagen: Relationship to Bone Strength , 1999, Calcified Tissue International.

[12]  R O Ritchie,et al.  Effect of aging on the toughness of human cortical bone: evaluation by R-curves. , 2004, Bone.

[13]  B. van Rietbergen,et al.  COMPUTATIONAL STRATEGIES FOR ITERATIVE SOLUTIONS OF LARGE FEM APPLICATIONS EMPLOYING VOXEL DATA , 1996 .

[14]  D. Burr,et al.  Microdamage and bone strength , 2003, Osteoporosis International.

[15]  L. Mosekilde Age-related changes in vertebral trabecular bone architecture--assessed by a new method. , 1988, Bone.

[16]  T. Keaveny,et al.  Systematic and random errors in compression testing of trabecular bone , 1997, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  T. Hansson,et al.  Microcalluses of the Trabeculae in Lumbar Vertebrae and Their Relation to the Bone Mineral Content , 1981, Spine.

[18]  Xiaodu Wang,et al.  The Toughness of Cortical Bone and Its Relationship with Age , 2004, Annals of Biomedical Engineering.

[19]  W C Hayes,et al.  Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus. , 1994, Journal of biomechanics.

[20]  R. Huiskes,et al.  A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. , 1995, Journal of biomechanics.

[21]  C. M. Agrawal,et al.  Age-related changes in the collagen network and toughness of bone. , 2002, Bone.

[22]  C. Turner Biomechanics of Bone: Determinants of Skeletal Fragility and Bone Quality , 2002, Osteoporosis International.

[23]  F. Prêteux,et al.  Measurement of anisotropic vertebral trabecular bone loss during aging by quantitative image analysis , 1988, Calcified Tissue International.

[24]  P. Rüegsegger,et al.  Direct Three‐Dimensional Morphometric Analysis of Human Cancellous Bone: Microstructural Data from Spine, Femur, Iliac Crest, and Calcaneus , 1999, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[25]  W C Hayes,et al.  Sequential labelling of microdamage in bone using chelating agents , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[26]  F. Prêteux,et al.  Automatic quantification of vertebral cancellous bone remodeling during aging , 2005, Anatomia Clinica.

[27]  M. V. D. van der Meulen,et al.  Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation. , 2004, Journal of biomechanics.

[28]  R E Guldberg,et al.  The accuracy of digital image-based finite element models. , 1998, Journal of biomechanical engineering.

[29]  L. Mosekilde,et al.  Sex differences in age-related loss of vertebral trabecular bone mass and structure--biomechanical consequences. , 1989, Bone.

[30]  Mitchell B. Schaffler,et al.  Role of bone turnover in microdamage , 2003, Osteoporosis International.

[31]  R. Martin,et al.  Fatigue Microdamage as an Essential Element of Bone Mechanics and Biology , 2003, Calcified Tissue International.

[32]  L. Mosekilde,et al.  Consequences of the remodelling process for vertebral trabecular bone structure: a scanning electron microscopy study (uncoupling of unloaded structures). , 1990, Bone and mineral.