Investigation of indoor air pollutant dispersion and cross-contamination around a typical high-rise residential building : wind tunnel tests

Abstract The dispersion of air pollutant in complex building environment has become of great concern as more and more people live in large and crowded cities. The present work is aimed at investigating the indoor air pollutant dispersion and possible cross-unit contamination with typical high-rise residential building design in Hong Kong. Experiments were performed in a boundary layer wind tunnel for a 1:30 scale model that represented a 10-story residential building in prototype. Tracer gas, simulating exhausted room air, was continuously released from three different floor levels, and its concentrations on the adjacent and opposite envelope surfaces were measured using fast flame ionization detectors, while the pressure distributions along building facade were also measured and examined under a typical incoming wind profile. By analyzing the pressure and concentration distribution, the risk of air cross-contamination was evaluated under two wind directions. The experiment results illustrated that, in the so-called re-entrance spaces, the pollutant can spread in both vertical directions, not only in the upward direction that was found under buoyancy effect, but also in the downward direction. Furthermore, dispersion can also occur in the horizontal direction, indicating a potential risk of cross-contamination in the horizontal adjacent flats could not be overlooked as well. The study on this physical process is directly useful for the purpose of prevention and control of infectious diseases outbreak in the residential environment. In the long run, the wind tunnel test data will serve to develop computational tools to assist natural ventilation design for high-rise buildings.

[1]  Theodore Stathopoulos,et al.  Effects of model scale in estimating pollutant dispersion near buildings , 1995 .

[2]  Richard Griffiths,et al.  Wind tunnel modelling of urban building exposure to outdoor pollution , 2005 .

[3]  M. Kanda Progress in the scale modeling of urban climate: Review , 2006 .

[4]  R. Ooka,et al.  Studies on critical Reynolds number indices for wind-tunnel experiments on flow within urban areas , 2003 .

[5]  Xiaoping Liu,et al.  Numerical simulation of inter-flat air cross-contamination under the condition of single-sided natural ventilation , 2008 .

[6]  Theodore Stathopoulos,et al.  Numerical evaluation of wind-induced dispersion of pollutants around a building , 1997 .

[7]  D. J. Hall,et al.  Flow and dispersion around an isolated building , 1996 .

[8]  Mukesh Khare,et al.  Wind tunnel simulation studies on dispersion at urban street canyons and intersections—a review , 2005 .

[9]  Dennis Y.C. Leung,et al.  On the prediction of air and pollutant exchange rates in street canyons of different aspect ratios using large-eddy simulation , 2005 .

[10]  David Hargreaves,et al.  Wind tunnel evaluation of a vehicle pollution dispersion model , 2001 .

[11]  John M. Cimbala,et al.  Indoor Air Quality Engineering: Environmental Health and Control of Indoor Pollutants , 2003 .

[12]  J. E. Cermak,et al.  Physical modelling of flow and dispersion over complex terrain , 1984 .

[13]  Richard Griffiths,et al.  Field experiments of dispersion through regular arrays of cubic structures , 1997 .

[14]  P. Heiselberg,et al.  The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation , 2007, Building and Environment.

[15]  J Niu,et al.  On-site quantification of re-entry ratio of ventilation exhausts in multi-family residential buildings and implications. , 2007, Indoor air.

[16]  S. Kot,et al.  Dispersion of vehicular emission in street canyons, Guangzhou City, South China (P.R.C.) , 1993 .

[17]  Tze Wai Wong,et al.  Evidence of airborne transmission of the severe acute respiratory syndrome virus. , 2004, The New England journal of medicine.

[18]  Guixiang Cui,et al.  Large eddy simulation of wind field and plume dispersion in building array , 2008 .

[19]  William H. Rae,et al.  Low-Speed Wind Tunnel Testing , 1966 .

[20]  R. Martinuzzi,et al.  Investigation of bluff body asymmetry on the properties of vortex shedding , 2008 .

[21]  Richard Griffiths,et al.  Field and wind tunnel investigations of plume dispersion around single surface obstacles , 2003 .

[22]  L. Jennings,et al.  Aerosol transmission of rhinovirus colds. , 1987, The Journal of infectious diseases.

[23]  Michael Schatzmann,et al.  Wind tunnel measurements of concentration fluctuations in an urban street canyon , 1999 .

[24]  Richard Griffiths,et al.  Local characteristics of atmospheric dispersion within building arrays , 2001 .

[25]  Kit Ming Lam,et al.  Recent progress in CFD modelling of wind field and pollutant transport in street canyons , 2006 .

[26]  K. Pericleous,et al.  Modelling air quality in street canyons : a review , 2003 .

[27]  Jack E. Cermak,et al.  Applications of Fluid Mechanics to Wind Engineering—A Freeman Scholar Lecture , 1975 .

[28]  Jianlei Niu,et al.  Some significant environmental issues in high-rise residential building design in urban areas , 2004 .

[29]  John Burnett,et al.  Wind-induced pressure at external surfaces of a high-rise residential building in Hong Kong , 2005 .