Sufficient Statistics as a Generalization of Binning in Spectral X-ray Imaging

It is well known that the energy dependence of X-ray attenuation can be used to characterize materials. Yet, even with energy discriminating photon counting X-ray detectors, it is still unclear how to best form energy dependent measurements for spectral imaging. Common ideas include binning photon counts based on their energies and detectors with both photon counting and energy integrating electronics. These approaches can be generalized to energy weighted measurements, which we prove can form a sufficient statistic for spectral X-ray imaging if the weights used, which we term μ-weights, are basis attenuation functions that can also be used for material decomposition. To study the performance of these different methods, we evaluate the Cramér-Rao lower bound (CRLB) of material estimates in the presence of quantum noise. We found that the choice of binning and weighting schemes can greatly affect the performance of material decomposition. Even with optimized thresholds, binning condenses information but incurs penalties to decomposition precision and is not robust to changes in the source spectrum or object size, although this can be mitigated by adding more bins or removing photons of certain energies from the spectrum. On the other hand, because μ -weighted measurements form a sufficient statistic for spectral imaging, the CRLB of the material decomposition estimates is identical to the quantum noise limited performance of a system with complete energy information of all photons. Finally, we show that μ -weights lead to increased conspicuity over other methods in a simulated calcium contrast experiment.

[1]  A. Macovski,et al.  Generalized image combinations in dual KVP digital radiography. , 1981, Medical physics.

[2]  Katsuyuki Taguchi,et al.  A Poisson likelihood iterative reconstruction algorithm for material decomposition in CT , 2007, SPIE Medical Imaging.

[3]  G. Anton,et al.  The energy weighting technique: measurements and simulations , 2005 .

[4]  E. Roessl,et al.  Cramér–Rao lower bound of basis image noise in multiple-energy x-ray imaging , 2009, Physics in medicine and biology.

[5]  J. Boone,et al.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV. , 1997, Medical physics.

[6]  Alan V. Oppenheim,et al.  Discrete-time signal processing (2nd ed.) , 1999 .

[7]  Thilo Michel,et al.  Contrast agent recognition in small animal CT using the Medipix2 detector , 2009 .

[8]  C. McCollough,et al.  Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration. , 2009, Medical physics.

[9]  E. Roessl,et al.  On the influence of noise correlations in measurement data on basis image noise in dual-energylike x-ray imaging. , 2007, Medical physics.

[10]  A. Feuerverger,et al.  On Some Fourier Methods for Inference , 1981 .

[11]  A Fenster,et al.  Theoretical optimization of a split septaless xenon ionization detector for dual-energy chest radiography. , 1988, Medical physics.

[12]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[13]  A. W. M. van den Enden,et al.  Discrete Time Signal Processing , 1989 .

[14]  Cynthia H McCollough,et al.  Optimal Spectral Filtration for Dual-Energy and Dual-Source CT , 2009 .

[15]  G. Anton,et al.  The influence of energy weighting on X-ray imaging quality , 2004 .

[16]  Polad M Shikhaliev,et al.  Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging , 2006, Physics in medicine and biology.

[17]  P. Joseph,et al.  Noise considerations in dual energy CT scanning. , 1979, Medical physics.

[18]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[19]  N. Wermes,et al.  CIX: a detector for spectrally enhanced x-ray imaging by simultaneous counting and integrating , 2008, SPIE Medical Imaging.

[20]  N J Pelc,et al.  Depth-segmented detector for x-ray absorptiometry. , 2000, Medical physics.

[21]  Adam Wang,et al.  Optimal energy thresholds and weights for separating materials using photon counting x-ray detectors with energy discriminating capabilities , 2009, Medical Imaging.

[22]  C. Herrmann,et al.  Counting and integrating readout for direct conversion X-ray imaging concept, realization and first prototype measurements , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[23]  J H Siewerdsen,et al.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization. , 2004, Medical physics.

[24]  M Danielsson,et al.  Detective quantum efficiency dependence on x-ray energy weighting in mammography. , 1999, Medical physics.

[25]  G T Barnes,et al.  Detector for dual-energy digital radiography. , 1985, Radiology.

[26]  A. Feuerverger,et al.  The Empirical Characteristic Function and Its Applications , 1977 .

[27]  Gisela Anton,et al.  Using the Medipix2 detector for energy weighting , 2005 .

[28]  R. F. Wagner,et al.  SNR and DQE analysis of broad spectrum X-ray imaging , 1985 .

[29]  S. Kay Fundamentals of statistical signal processing: estimation theory , 1993 .

[30]  P. King Medical imaging systems , 1986, Proceedings of the IEEE.