Control strategies for sub-micrometer particles indoors: model study of air filtration and ventilation.

The effects of air filtration and ventilation on indoor particles were investigated using a single-zone mathematical model. Particle concentration indoors was predicted for several I/O conditions representing scenarios likely to occur in naturally and mechanically ventilated buildings. The effects were studied for static and dynamic conditions in a hypothetical office building. The input parameters were based on real-world data. For conditions with high particle concentrations outdoors, it is recommended to reduce the amount of outdoor air delivered indoors and the necessary reduction level can be quantified by the model simulation. Consideration should also be given to the thermal comfort and minimum outdoor air required for occupants. For conditions dominated by an indoor source, it is recommended to increase the amount of outdoor air delivered indoors and to reduce the amount of return air. Air filtration and ventilation reduce particle concentrations indoors, with the overall effect depending on efficiency, location and the number of filters applied. The assessment of indoor air quality for specific conditions could be easily calculated by the model using user-defined input parameters.

[1]  D. Michell,et al.  Air permeability of some Australian houses , 1986 .

[2]  Kenneth L. Heitner,et al.  Theoretical model for relating indoor pollutant concentrations to those outside , 1974 .

[3]  W W Nazaroff,et al.  Mathematical modeling of chemically reactive pollutants in indoor air. , 1986, Environmental science & technology.

[4]  Jackson,et al.  Verification and uses of the Environmental Protection Agency (EPA) indoor air quality model , 1989 .

[5]  C. Pope,et al.  Daily mortality and PM10 pollution in Utah Valley. , 1992, Archives of environmental health.

[6]  D. Dockery,et al.  An association between air pollution and mortality in six U.S. cities. , 1993, The New England journal of medicine.

[7]  J. Xue,et al.  Personal exposure to airborne particles and metals: results from the Particle TEAM study in Riverside, California. , 1996, Journal of exposure analysis and environmental epidemiology.

[8]  L Morawska,et al.  Effect of ventilation and filtration on submicrometer particles in an indoor environment. , 2000, Indoor air.

[9]  William W. Nazaroff,et al.  Particle Deposition in Museums: Comparison of Modeling and Measurement Results , 1990 .

[10]  Charles J Weschler,et al.  Understanding and Reducing the Indoor Concentration of Submicron Particles at a Commercial Building in Southern California. , 2012, Journal of the Air & Waste Management Association.

[11]  J. Schwartz,et al.  Mortality and air pollution in London: a time series analysis. , 1990, American journal of epidemiology.

[12]  Antony J. H. Goddard,et al.  Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios , 1997 .

[13]  T. Yamamoto,et al.  Evaluation of ventilation performance for indoor space , 1994 .

[14]  R. Letz,et al.  Estimating human exposure to nitrogen dioxide: an indoor/outdoor modeling approach. , 1983, Environmental research.

[15]  William W. Nazaroff,et al.  Mathematical Modeling of Indoor Aerosol Dynamics , 1989 .

[16]  John D. Spengler,et al.  Indoor-outdoor relationships of respirable sulfates and particles , 1981 .

[17]  H. N. Jow,et al.  Indoor-outdoor relationships for airborne particulate matter of outdoor origin , 1979 .

[18]  Liisa Pirjola,et al.  Indoor air aerosol model: the effect of outdoor air, filtration and ventilation on indoor concentrations , 1999 .

[19]  Derek Dunn-Rankin,et al.  Using numerical simulation to predict ventilation efficiency in a model room , 1998 .

[20]  William W. Nazaroff,et al.  Mixing of a Point Source Pollutant by Natural Convection Flow within a Room , 1994 .

[21]  Anthony S. Wexler,et al.  Modelling urban and regional aerosols—I. model development , 1994 .

[22]  Tracy L. Thatcher,et al.  Deposition, resuspension, and penetration of particles within a residence , 1995 .

[23]  D. Dockery,et al.  Acute respiratory effects of particulate air pollution. , 1994, Annual review of public health.

[24]  Markus Olin,et al.  Indoor Air Aerosol Model: Transport Indoors and Deposition of Fine and Coarse Particles , 1989 .

[25]  John H. Seinfeld,et al.  Simulation of multicomponent aerosol dynamics , 1992 .

[26]  L. Morawska,et al.  Quantitative Assessment of the Effect of Surface Deposition and Coagulation on the Dynamics of Submicrometer Particles Indoors , 2003 .

[27]  Lidia Morawska,et al.  Comprehensive characterization of aerosols in a subtropical urban atmosphere : Particle size distribution and correlation with gaseous pollutants , 1998 .

[28]  William W. Nazaroff,et al.  Critique of the Use of Deposition Velocity in Modeling Indoor Air Quality , 1993 .

[29]  L. Wallace,et al.  Indoor particles: a review. , 1996, Journal of the Air & Waste Management Association.

[30]  A. Peters,et al.  Respiratory effects are associated with the number of ultrafine particles. , 1997, American journal of respiratory and critical care medicine.

[31]  L Morawska,et al.  Relation between indoor and outdoor exposure to fine particles near a busy arterial road. , 1999, Indoor air.

[32]  Thomas Schneider,et al.  A two compartment model for determining the contribution of sources, surface deposition and resuspension to air and surface dust concentration levels in occupied rooms , 1999 .

[33]  Relationships between indoor and outdoor contaminants in mechanically ventilated buildings , 1996 .

[34]  Kaarle Hämeri,et al.  Spatial variation of aerosol number concentration in Helsinki city , 1999 .