Modeling and simulation of a PEM fuel cell stack considering temperature effects

Management of the water and heat ejected as byproducts in an operating PEM fuel cell stack are crucial factors in their optimal design and safe operations. Models currently available for a PEM fuel cell are based on either empirical or 3-D computational fluid dynamics (CFD). Both models do not fully meet the need to represent physical behavior of a stack because of either their simplicity or complexity. We propose a highly dynamic PEM fuel cell stack model, taking into account the most influential property of temperature affecting performance and dynamics. Simulations have been conducted to analyze start-up behaviors and the performance of the stack in conjunction with the cells. Our analyses demonstrate static and dynamic behaviors of a stack. Major results presented are as follows: (1) operating dependent temperature gradient across through-plane direction of the fuel cell stack, (2) endplate effects on the temperature profile during start-up process, (3) temperature profile influences on the output voltage of individual cells and the stack, (4) temperature influence on the water content in membranes of different cells, and (5) cathode inlet relative humidity influence on the temperature profile of the stack.

[1]  Markku J. Lampinen,et al.  Analysis of Free Energy and Entropy Changes for Half‐Cell Reactions , 1993 .

[2]  Ned Djilali,et al.  CFD-based modelling of proton exchange membrane fuel cells , 2005 .

[3]  Massimo Ceraolo,et al.  Modelling static and dynamic behaviour of proton exchange membrane fuel cells on the basis of electro-chemical description , 2003 .

[4]  Xianguo Li,et al.  Mathematical modeling of proton exchange membrane fuel cells , 2001 .

[5]  Karl-Heinz Hauer,et al.  A dynamic simulation tool for hydrogen fuel cell vehicles , 2005 .

[6]  Chaoyang Wang,et al.  Two-Phase Modeling and Flooding Prediction of Polymer Electrolyte Fuel Cells , 2005 .

[7]  J. C. Amphlett,et al.  A model predicting transient responses of proton exchange membrane fuel cells , 1996 .

[8]  Song-Yul Choe,et al.  A high dynamic PEM fuel cell model with temperature effects , 2005 .

[9]  S. Dutta,et al.  NUMERICAL PREDICTION OF TEMPERATURE DISTRIBUTION IN PEM FUEL CELLS , 2000 .

[10]  J. H. Lee,et al.  Modeling fuel cell stack systems , 1998 .

[11]  Anna G. Stefanopoulou,et al.  Control-Oriented Modeling and Analysis for Automotive Fuel Cell Systems , 2004 .

[12]  Chao-Yang Wang,et al.  Transient analysis of polymer electrolyte fuel cells , 2005 .

[13]  B. Wetton,et al.  Water Management in PEM Fuel Cells , 2004 .

[14]  M. Wöhr,et al.  Dynamic modelling and simulation of a polymer membrane fuel cell including mass transport limitation , 1998 .

[15]  Y. M. Ferng,et al.  Analytical and experimental investigations of a proton exchange membrane fuel cell , 2004 .

[16]  Trung Van Nguyen,et al.  Three-dimensional effects of liquid water flooding in the cathode of a PEM fuel cell , 2003 .

[17]  R. M. Moore,et al.  Polymer electrolyte fuel cell stack thermal model to evaluate sub-freezing startup , 2005 .

[18]  Hyunchul Ju,et al.  A single-phase, non-isothermal model for PEM fuel cells , 2005 .

[19]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.