The GOME-2 instrument on the Metop series of satellites: instrument design, calibration, and level 1 data processing – an overview

Abstract. The Global Ozone Monitoring Experiment-2 (GOME-2) flies on the Metop series of satellites, the space component of the EUMETSAT Polar System. In this paper we will provide an overview of the instrument design, the on-ground calibration and characterization activities, in-flight calibration, and level 0 to 1 data processing. The current status of the level 1 data is presented and points of specific relevance to users are highlighted. Long-term level 1 data consistency is also discussed and plans for future work are outlined. The information contained in this paper summarizes a large number of technical reports and related documents containing information that is not currently available in the published literature. These reports and documents are however made available on the EUMETSAT web pages and readers requiring more details than can be provided in this overview paper will find appropriate references at relevant points in the text.

[1]  Piet Stammes,et al.  On the relationship between Stokes parameters Q and U of atmospheric ultraviolet//visible//near-infrared radiation , 2004 .

[2]  H. Bovensmann,et al.  SCIAMACHY Degradation Monitoring Results , 2007 .

[3]  Ruediger Lang,et al.  Characterization and correction of Global Ozone Monitoring Experiment 2 ultraviolet measurements and application to ozone profile retrievals , 2012 .

[4]  M. V. Roozendael,et al.  FRESCO+: an improved O 2 A-band cloud retrieval algorithm for tropospheric trace gas retrievals , 2008 .

[5]  Sander Slijkhuis,et al.  Long-term analysis of GOME in-flight calibration parameters and instrument degradation. , 2008, Applied optics.

[6]  Hans Bonekamp,et al.  An Introduction to the EUMETSAT Polar system , 2007 .

[7]  Christos Zerefos,et al.  Overview of the O3M SAF GOME-2 operational atmospheric composition and UV radiation data products and data availability , 2015 .

[8]  GOME-2 on MetOp-A Support for Analysis of GOME-2 In-Orbit Degradation and Impacts on Level 2 Data Products Final Report , 2011 .

[9]  Diego G. Loyola,et al.  Cloud Properties Derived From GOME/ERS-2 Backscatter Data for Trace Gas Retrieval , 2007, IEEE Transactions on Geoscience and Remote Sensing.

[10]  A. Hahne,et al.  GOME-2 – Metop ’ s Second-Generation Sensor for Operational Ozone Monitoring , 2000 .

[11]  L. G. Tilstra,et al.  Contiguous polarisation spectra of the Earth from 300 to 850 nm measured by GOME-2 onboard MetOp-A , 2013 .

[12]  P. Stammes,et al.  Support for upgrade to FRESCO+ in the GOME-2 PPF , 2010 .

[13]  Ilse Aben,et al.  Mirror contamination in space I: mirror modelling , 2014 .

[14]  S. Beirle,et al.  Linearisation of the effects of spectral shift and stretch in DOAS analysis , 2012 .

[15]  Sander Slijkhuis,et al.  Re-analysis of GOME/ERS-2 Diffuser properties , 2004 .

[16]  Jos van Geffen Wavelength calibration of spectra measured by the Global Ozone Monitoring Experiment: variations along orbits and in time. , 2004 .

[17]  Michael Eisinger,et al.  GOME-2 on MetOp , 2006 .