A tetrahedron beam computed tomography benchtop system with a multiple pixel field emission x-ray tube.
暂无分享,去创建一个
Joshua Kim | Tiezhi Zhang | Xiaochao Xu | Tiezhi Zhang | Yongguang Liang | Joshua Kim | Derek Schulze | Philip Laganis | Yongguang Liang | D. Schulze | Xiaochao Xu | P. Laganis
[1] R Peng,et al. A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source , 2009, Physics in medicine and biology.
[2] Taly Gilat Schmidt,et al. A prototype table‐top inverse‐geometry volumetric CT system , 2006 .
[3] Jonathan S. Maltz,et al. Fixed gantry tomosynthesis system for radiation therapy image guidance based on a multiple source x-ray tube with carbon nanotube cathodes. , 2009 .
[4] Tuyen Phan,et al. Design and characterization of a spatially distributed multibeam field emission x-ray source for stationary digital breast tomosynthesis. , 2009, Medical physics.
[5] J H Siewerdsen,et al. Cone-beam computed tomography with a flat-panel imager: effects of image lag. , 1999, Medical physics.
[6] O. Zhou,et al. Very large current density from carbon nanotube field emitters , 1999, International Electron Devices Meeting 1999. Technical Digest (Cat. No.99CH36318).
[7] Otto Zhou,et al. Multiplexing radiography using a carbon nanotube based x-ray source , 2006 .
[8] Rebecca Fahrig,et al. Dose and image quality for a cone-beam C-arm CT system. , 2006, Medical physics.
[9] Michael A Speidel,et al. Scanning-beam digital x-ray (SBDX) technology for interventional and diagnostic cardiac angiography. , 2006, Medical physics.
[10] M. Endo,et al. Effect of scattered radiation on image noise in cone beam CT. , 2001, Medical physics.
[11] M. Oldham,et al. Cone-beam-CT guided radiation therapy: technical implementation. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[12] D. Jaffray,et al. Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography). , 2000, Medical physics.
[13] D. Jaffray,et al. Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. , 2001, Medical physics.
[14] C. Choy,et al. Dielectric properties and abnormal C-V characteristics of Ba[sub 0.5]Sr[sub 0.5]TiO₃-Bi[sub 1.5]ZnNb[sub 1.5]O[sub 7] composite thin films grown on MgO (001) substrates by pulsed laser deposition , 2006 .
[15] J. Wong,et al. Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.
[16] Joshua Kim,et al. Tetrahedron beam computed tomography (TBCT): a new design of volumetric CT system. , 2009, Physics in medicine and biology.