Design and evaluation of a new bioelectrical impedance sensor for micro-surgery: application to retinal vein cannulation

PurposeNowadays, millions of people suffer from retinal vein occlusion, a blind-making eye disease. No curative treatment currently exists for this vascular disorder. However, a promising treatment consists in injecting a thrombolytic drug directly inside the affected retinal vessel. Successfully puncturing miniature vessels with diameters between 50 and 400 $$\upmu \hbox {m}$$μm remains a real challenge, amongst others due to human hand tremor, poor visualisation and depth perception. As a consequence, there is a significant risk of double-puncturing the targeted vessel. Sub-surfacic injection of thrombolytic agent could potentially lead to severe retinal damage.MethodsA new bio-impedance sensor has been developed to visually display the instant of vessel puncture. The physical working principle of the sensor has been analysed, and a representative electrical model has been derived. Based on this model, the main design parameters were derived to maximise the sensor sensitivity. A detailed characterisation and experimental validation of this concept were conducted.ResultsStable, repeatable and robust impedance measurements were obtained. In an experimental campaign, 35 puncture attempts on ex vivo pig eyes vessels were conducted. A confusion matrix shows a detection accuracy of 80% if there is a puncture, a double puncture or no puncture. The 20% of inaccuracy most probably comes from the limitations of the employed eye model and the experimental conditions.ConclusionsThe developed bio-impedance sensor has shown great promise to help in avoiding double punctures when cannulating retinal veins. Compared to other puncture detection methods, the proposed sensor is simple and therefore potentially more affordable. Future research will include validation in an in vivo situation involving vitreoretinal surgeons.

[1]  D Stoianovici,et al.  Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access. , 2001, The Journal of urology.

[2]  F Skovborg,et al.  Diameters of the Retinal Vessels in Diabetic and Normal Subjects , 1969, Diabetes.

[3]  J. Weiss,et al.  Injection of tissue plasminogen activator into a branch retinal vein in eyes with central retinal vein occlusion. , 2001, Ophthalmology.

[4]  Zhuoqi Cheng,et al.  A New Venous Entry Detection Method Based on Electrical Bio-impedance Sensing , 2018, Annals of Biomedical Engineering.

[5]  Dominiek Reynaerts,et al.  Experimental Validation of a Robotic Comanipulation and Telemanipulation System for Retinal Surgery , 2014, 5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics.

[6]  A W Partin,et al.  Bioimpedance: Novel use of a minimally invasive technique for cancer localization in the intact prostate , 1999, The Prostate.

[7]  T. Missotten,et al.  Updated cannulation technique for tissue plasminogen activator injection into peripapillary retinal vein for central retinal vein occlusion , 2015, Acta ophthalmologica.

[8]  Dominiek Reynaerts,et al.  Development and Experimental Validation of a Combined FBG Force and OCT Distance Sensing Needle for Robot-Assisted Retinal Vein Cannulation , 2018, 2018 IEEE International Conference on Robotics and Automation (ICRA).

[9]  Tien Yin Wong,et al.  The prevalence of retinal vein occlusion: pooled data from population studies from the United States, Europe, Asia, and Australia. , 2010, Ophthalmology.

[10]  Kohji Mitsubayashi,et al.  Detection of needle puncture to blood vessel by using electric conductivity of blood for automatic blood sampling , 2006 .

[11]  Russell H. Taylor,et al.  Force-sensing microneedle for assisted retinal vein cannulation , 2014, IEEE SENSORS 2014 Proceedings.

[12]  Ronald Klein,et al.  The 15-year cumulative incidence of retinal vein occlusion: the Beaver Dam Eye Study. , 2008, Archives of ophthalmology.

[13]  Cameron N. Riviere,et al.  A study of instrument motion in retinal microsurgery , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[14]  Bernd Junker,et al.  Retinal endovascular lysis in ischemic central retinal vein occlusion: one-year results of a pilot study. , 2007, Ophthalmology.

[15]  J N Weiss Retinal surgery for treatment of central retinal vein occlusion. , 2000, Ophthalmic surgery and lasers.

[16]  Matus Rehak,et al.  Branch Retinal Vein Occlusion: Pathogenesis, Visual Prognosis, and Treatment Modalities , 2008, Current eye research.

[17]  Dominiek Reynaerts,et al.  Development and experimental validation of a force sensing needle for robotically assisted retinal vein cannulations , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[18]  Arvi Yli-Hankala,et al.  Detection of spine structures with Bioimpedance Probe (BIP) Needle in clinical lumbar punctures , 2017, Journal of Clinical Monitoring and Computing.