Influence of wall luminance and uniformity on preferred task illuminance

Abstract Literature suggests an influence of the luminance from non-horizontal surfaces in our visual field on our visual and psychological assessments of an office space. These assessments are believed to directly relate to our expressed preferred task illuminances. This paper describes an evaluation in a mock-up office, wherein wall conditions with a non-uniform and a more uniform light distribution of 3 different average luminance levels have been evaluated regarding their effect on users' preferred task illuminance. Each condition is evaluated starting from three different initial desk illuminances. For all test conditions, a wall with a non-uniformly distributed average luminance of 200 cd/m2 lead to significantly lower selected desk illuminances than a uniformly lit wall with the same average luminance level. In all cases, preferred task illuminances set were significantly lower when offering the lowest starting level for dimming of 300 lx. The range of preferred illuminance levels between subjects was also found to be smaller for dimming with the starting level of 300 lx at desk level. The study suggests that when providing users with personal control they will control the total perceived brightness in their visual field, even though they are only directly affecting their task illuminance level. Triggering the selection of lower preferred illuminance levels due to a personal control starting level of 300 lx, will positively influence the energy used for lighting. The smaller range of preferred illuminance levels between subjects at the starting of 300 lx could reduce the risk of lighting preference related conflict between people. However, more research is needed to confirm that these smaller differences are also perceivable by users.

[1]  C. Cuttle,et al.  Perceived adequacy of illumination, spatial brightness, horizontal illuminance and mean room surface exitance in a small office , 2017 .

[2]  Peter Boyce,et al.  Individual Lighting Control: Task Performance, Mood, and Illuminance , 2000 .

[3]  J Uttley,et al.  Satisfaction and illuminances set with user-controlled lighting , 2013 .

[4]  S. Kuai,et al.  Study of preferred background luminance in watching computer screen in children , 2014, Chinese medical journal.

[5]  Nilgün Olguntürk,et al.  Impact of lighting arrangements and illuminances on different impressions of a room , 2007 .

[6]  Alison Williams,et al.  Lighting Controls in Commercial Buildings , 2012 .

[7]  Iason Konstantzos,et al.  Occupant interactions with shading and lighting systems using different control interfaces: A pilot field study , 2016 .

[8]  Sanae Chraibi,et al.  Lighting preference profiles of users in an open office environment , 2017 .

[9]  Dj Carter,et al.  A study of opinion in offices with and without user controlled lighting , 2004 .

[10]  MS Islam,et al.  User acceptance studies for LED office lighting: Lamp spectrum, spatial brightness and illuminance , 2015 .

[11]  Sanae Chraibi,et al.  Satisfying light conditions: a field study on perception of consensus light in Dutch open office environments , 2016 .

[12]  Banu Manav,et al.  An experimental study on the appraisal of the visual environment at offices in relation to colour temperature and illuminance , 2007 .

[13]  Peter Boyce,et al.  Occupant use of switching and dimming controls in offices , 2006 .

[14]  Dj Carter,et al.  A qualitative study of occupant controlled office lighting , 2003 .

[15]  Guy R. Newsham,et al.  Lighting quality recommendations for VDT offices: a new method of derivation , 2001 .

[16]  Peter Boyce,et al.  Lighting quality and office work: two field simulation experiments , 2006 .

[17]  J. Sheedy,et al.  Visual effects of the luminance surrounding a computer display , 2005, Ergonomics.

[18]  Jennifer A. Veitch,et al.  Perceived room brightness: Pilot study on the effect of luminance distribution , 1995 .

[19]  S. H. A. Begemann,et al.  Preferred Luminances in Offices , 1987 .

[20]  Jennifer A. Veitch,et al.  Preferred Surface Luminances in Offices, by Evolution , 2004 .

[21]  J. Christoffersen,et al.  Using Adjustment to Define Preferred Illuminances: Do the Results Have Any Value? , 2011 .

[22]  Jennifer A. Veitch,et al.  Preferred luminous conditions in open-plan offices: research and practice recommendations , 2000 .

[23]  Steve Fotios,et al.  Lighting in offices: lamp spectrum and brightness , 2011 .

[24]  C Cuttle,et al.  Brightness, lightness, and providing ‘a preconceived appearance to the interior’ , 2004 .

[25]  Peter Boyce,et al.  Lighting appraisal, well-being and performance in open-plan offices: A linked mechanisms approach , 2008 .