Numerical simulation of liquid velocity distribution in a sonochemical reactor.

Ultrasonically induced flow is an important phenomenon observed in a sonochemical reactor. It controls the mass transport of sonochemical reaction and enhances the reaction performance. In the present paper, the liquid velocity distribution of ultrasonically induced flow in the sonochemical reactor with a transducer at frequency of 490 kHz has been numerically simulated. From the comparison of simulation results and experimental data, the ultrasonic absorption coefficient in the sonochemical reactor has been evaluated. To simulate the liquid velocity near the liquid surface above the transducer, which is the main sonochemical reaction area, it is necessary to include the acoustic fountain shape into the computational domain. The simulation results indicate that the liquid velocity increases with acoustic power. The variation of liquid height also influences the behavior of liquid velocity distribution and the mean velocity above the transducer centre becomes a maximum when the liquid height is 0.4m. The liquid velocity decreases with increasing the transducer plate radius at the same ultrasonic power.

[1]  Wesley L. Nyborg,et al.  Acoustic Streaming due to Attenuated Plane Waves , 1953 .

[2]  K. M. Swamy,et al.  Modeling of three-dimensional pressure fields in sonochemical reactors with an inhomogeneous density distribution of cavitation bubbles. Comparison of theoretical and experimental results. , 1999, Ultrasonics sonochemistry.

[3]  K. Yasui,et al.  Multibubble sonoluminescence enhancement by fluid flow. , 2006, Ultrasonics.

[4]  Masaaki Nakamura,et al.  Enhancement of sonochemical reaction of terephthalate ion by superposition of ultrasonic fields of various frequencies. , 2007, Ultrasonics sonochemistry.

[5]  S. Aanonsen,et al.  Distortion and harmonic generation in the nearfield of a finite amplitude sound beam , 1984 .

[6]  D. Rijken,et al.  Acceleration of fibrinolysis by high-frequency ultrasound: the contribution of acoustic streaming and temperature rise. , 2000, Thrombosis research.

[7]  T. Tuziuti,et al.  Effects of Nonlinearity in Development of Acoustic Streaming , 1995 .

[8]  M. Entezari,et al.  Effect of frequency on sonochemical reactions II. Temperature and intensity effects , 1996 .

[9]  Inez Hua,et al.  Impact of Ultrasonic Frequency on Aqueous Sonoluminescence and Sonochemistry , 2001 .

[10]  K. Yasuda,et al.  Enhancement of Sonochemical Reaction by Dual-Pulse Ultrasound , 2011 .

[11]  K. Matsuda,et al.  Time evolution of acoustic streaming from a planar ultrasound source , 1996 .

[12]  Y. Gonthier,et al.  Velocity study in an ultrasonic reactor. , 2000, Ultrasonics sonochemistry.

[13]  Y. Asakura,et al.  The effects of acoustic flow and mechanical flow on the sonochemical efficiency in a rectangular sonochemical reactor. , 2010, Ultrasonics sonochemistry.

[14]  Y Bailly,et al.  Modification of the ultrasound induced activity by the presence of an electrode in a sono-reactor working at two low frequencies (20 and 40 kHz). Part II: Mapping flow velocities by particle image velocimetry (PIV). , 2009, Ultrasonics sonochemistry.

[15]  Shinobu Koda,et al.  Effects of ultrasonic frequency and liquid height on sonochemical efficiency of large-scale sonochemical reactors. , 2008, Ultrasonics sonochemistry.

[16]  N. Gondrexon,et al.  A comparative study between classical stirred and ultrasonically-assisted dead-end ultrafiltration. , 2000, Ultrasonics sonochemistry.

[17]  G. Trahey,et al.  A finite element model for simulating acoustic streaming in cystic breast lesions with experimental validation , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  J. Wu,et al.  Acoustic streaming generated by a focused Gaussian beam and finite amplitude tonebursts. , 1993, Ultrasound in medicine & biology.

[19]  Y. Adewuyi,et al.  Sonochemistry: Environmental Science and Engineering Applications , 2001 .

[20]  K. Knoerzer,et al.  A computational modeling approach of the jet-like acoustic streaming and heat generation induced by low frequency high power ultrasonic horn reactors. , 2011, Ultrasonics sonochemistry.

[21]  Hideto Mitome,et al.  A standard method to calibrate sonochemical efficiency of an individual reaction system. , 2003, Ultrasonics sonochemistry.

[22]  Y. Bailly,et al.  Modification of the ultrasound induced activity by the presence of an electrode in a sonoreactor working at two low frequencies (20 and 40 kHz). Part I: Active zone visualization by laser tomography. , 2009, Ultrasonics sonochemistry.

[23]  C. J. Burton A Study of Ultrasonic Velocity and Absorption in Liquid Mixtures , 1948 .

[24]  Y. Asakura,et al.  Ultrasonic Atomization Amount for Different Frequencies , 2011 .

[25]  John King,et al.  FEM calculation of an acoustic field in a sonochemical reactor. , 2007, Ultrasonics sonochemistry.

[26]  K. Yasuda,et al.  Effect of Liquid Mixing on Performance of Porphyrin Decomposition by Ultrasonic Irradiation , 1999 .