Estimating uncertainties of the geometrical range of particle radiotherapy during respiration.

PURPOSE To propose a method for estimating uncertainties of the range calculation in particle radiotherapy associated with patient respiration. MATERIALS AND METHODS A set of sequential CT images at every 0.2 s was reconstructed from continuous X-ray projection data accumulated by dynamic helical scanning. At the same time that CT data was acquired, the respiratory signal of the patient and the X-ray on/off signal on CT scanner were recorded. Each CT image was timed according to the phase of respiration waveform. Conversion of the CT number to the water equivalent path length (WEL) was performed with our treatment planning system that included a conversion table. As an illustration, the CT images of a patient with liver cancer at the right upper lobe were analyzed. The geometric size of the liver and WELs from body surface to isocenter were measured in each CT image. RESULTS Variations of WEL from body surface to isocenter at the anterior-posterior and posterior-anterior direction were 6.2 mm and 18.9 mm, respectively. Liver size changed by 35.2 mm. However, these variations were shown to be considerably reduced by gated irradiation. CONCLUSIONS A method using sequential CT images with respiration waveform was proposed. It appeared to be useful in evaluating the uncertainties of the range calculation associated with patient breathing.

[1]  G. Chen,et al.  Treatment planning for heavy ion radiotherapy. , 1979, International journal of radiation oncology, biology, physics.

[2]  S Minohara,et al.  Respiratory gated irradiation system for heavy-ion radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[3]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[4]  S Minohara,et al.  Relationship between CT number and electron density, scatter angle and nuclear reaction for hadron-therapy treatment planning. , 1998, Physics in medicine and biology.

[5]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[6]  Shinichi Minohara,et al.  HIPLAN-A HEAVY ION TREATMENT PLANNING SYSTEM AT HIMAC , 1996 .

[7]  S Minohara,et al.  Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy. , 1999, International journal of radiation oncology, biology, physics.

[8]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.