Mechanical eye model for evaluation of intraocular pressure measuring under consideration of the biomechanical characteristics

A mechanical eye model has been developed which offers the possibility to set up, carry out and to evaluate intraocular pressure (IOP) measurements under consideration of different biomechanical characteristics. These characteristics are realized by designing model components with various geometries and material properties. Two different cornea thicknesses have been investigated, simulating different inner pressures via a controlled mechanical system, consisting of eyeball-like fluid-filled chamber whose pressure could be altered and measured. Results show significant characteristics in the signals recorded via test sensor as tonometry system, which are in line with medical predications. Using this model the evaluation of tonometry systems under considerations of biomechanical characteristics and environmental conditions can be done.

[1]  Sheng-Yao Hsu,et al.  Intraocular pressure assessment in both eyes of the same patient after laser in situ keratomileusis , 2009, Journal of cataract and refractive surgery.

[2]  A. Sinha Roy,et al.  Patient-specific modeling of corneal refractive surgery outcomes and inverse estimation of elastic property changes. , 2011, Journal of biomechanical engineering.

[3]  J. Lamparter,et al.  Messung des Augeninnendrucks (Tonometrie) mit unterschiedlichen Verfahren , 2009, Der Ophthalmologe.

[4]  J. Lace,et al.  A comparison of the elastic properties of human choroid and sclera. , 1988, Experimental eye research.

[5]  R L Reuben,et al.  Dynamic measurement of intraocular pressure using a mechanical model of the human eye. , 2008, Studies in health technology and informatics.

[6]  Y. Hashash,et al.  Effect of cornea material stiffness on measured intraocular pressure. , 2008, Journal of biomechanics.

[7]  Sarah J Manoogian,et al.  Dynamic material properties of the human sclera. , 2009, Journal of biomechanics.

[8]  T. Juhász,et al.  Finite element analysis applied to cornea reshaping. , 2005, Journal of biomedical optics.

[9]  M. O'Keefe,et al.  Measurement of intraocular pressure in LASIK and LASEK patients using the Reichert Ocular Response Analyzer and Goldmann applanation tonometry. , 2008, Journal of refractive surgery.

[10]  Jay S Pepose,et al.  Postoperative changes in intraocular pressure and corneal biomechanical metrics: Laser in situ keratomileusis versus laser‐assisted subepithelial keratectomy , 2009, Journal of cataract and refractive surgery.

[11]  Lee Ann Remington Chapter 1 – Visual System , 2005 .

[12]  L. Viernstein,et al.  An instrument for constant-pressure tonography. , 1979, Experimental eye research.

[13]  Akihiko Tawara,et al.  The Influence of Central Corneal Thickness and Corneal Curvature Radius on The Intraocular Pressure as Measured By Different Tonometers: Noncontact and Goldmann Applanation Tonometers , 2008, Journal of glaucoma.