Blood Pressure Estimation According to Photoplethysmographic Signal

This paper proposes a method for indirect systolic blood pressure estimation based on photoplethysmographic signal steepness. The proposed method was evaluated on 10 healthy subjects, aged 25±3 yrs., including 8 males and 2 females. The photoplethysmographic signal was obtained using a photoplethysmography device that is put on a finger, while reference blood pressure was measured using a semi-automatic OMRON blood pressure monitor. A significant 0.8550.025 (p < 0.001) correlation between the photoplethysmographic signal steepness and systolic blood pressure was discovered. The estimated systolic blood pressure obtained using the proposed method differed from the reference blood pressure by 3.8±4.2mmHg. The obtained results meet the AAMI (Association for the Advancement of Medical Instrumentation) requirements (5 ± 8mmHg). The results demonstrate that the photoplethysmographic signal wavefront can be applied successfully in wearable devices that can be used for 24 hour registration of blood pressure for both home use and clinical practice.

[1]  N. Westerhof,et al.  An artificial arterial system for pumping hearts. , 1971, Journal of applied physiology.

[2]  E. O’Brien,et al.  The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. , 1990, Journal of hypertension.

[3]  R. Fronsko,et al.  Evaluation of the influence of movement on saturation readings from pulse oximeters , 1995, Anaesthesia.

[4]  S J Barker,et al.  Effects of Motion on the Performance of Pulse Oximeters in Volunteers , 1996, Anesthesiology.

[5]  Armando Barreto,et al.  Adaptive pre-processing of photoplethysmographic blood volume pulse measurements , 1996, Proceedings of the 1996 Fifteenth Southern Biomedical Engineering Conference.

[6]  Steven J. Barker,et al.  The effects of motion on the performance of pulse oximeters in volunteers (revised publication). , 1997 .

[7]  S. Greenwald,et al.  Non invasive measurement of vascular compliance by a photoplesythmographic technique : Diagnostic and therapeutic Cardiovascular interventions VII , 1997 .

[8]  M. Olufsen Structured tree outflow condition for blood flow in larger systemic arteries. , 1999, The American journal of physiology.

[9]  J M Mallion,et al.  Study of arterial blood pressure by a Windkessel-type model: influence of arterial functional properties. , 1999, Computer methods and programs in biomedicine.

[10]  G. McVeigh,et al.  Nitric oxide modulation of blood vessel tone identified by arterial waveform analysis. , 2001, Clinical science.

[11]  C Mekkaoui,et al.  Simultaneous measurements of arterial diameter and blood pressure to determine the arterial compliance, wall mechanics and stresses in vivo. , 2001, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[12]  Partha Pratim Kanjilal,et al.  Analysis and characterization of photo-plethysmographic signal , 2001, IEEE Transactions on Biomedical Engineering.

[13]  Motoaki Sugawara,et al.  On-line noninvasive one-point measurements of pulse wave velocity , 2002, Heart and Vessels.

[14]  Alain Simon,et al.  Endothelium-dependent arterial wall tone elasticity modulated by blood viscosity. , 2002, American journal of physiology. Heart and circulatory physiology.

[15]  Duanping Liao,et al.  Hypertension, Blood Pressure, and Heart Rate Variability The Atherosclerosis Risk in Communities (ARIC) Study , 2003 .

[16]  G. McVeigh,et al.  Pulse waveform analysis and arterial wall properties. , 2003, Hypertension.

[17]  Y.T. Zhang,et al.  Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[18]  H. Sameshima,et al.  Continuous Systolic Blood Pressure Monitoring By the Difference in Electrocardiogram and Pulse Oximetry in Near-Term, Exteriorized Goat Fetuses , 2003, The Journal of the Society for Gynecologic Investigation: JSGI.

[19]  Dimitrios I. Fotiadis,et al.  Wearable Devices in Healthcare , 2005 .

[20]  Yuan-Ting Zhang,et al.  A near-infrared heart rate measurement IC with very low cutoff frequency using current steering technique , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[21]  J. V. van Lieshout,et al.  Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger , 2005, Experimental physiology.

[22]  A. P. Avó Multi-branched model of the human arterial system , 2006 .

[23]  P. Chowienczyk,et al.  Contour analysis of the photoplethysmographic pulse measured at the finger , 2006, Journal of hypertension.

[24]  Y.T. Zhang,et al.  The Evaluation of Wearable Cuff-less Blood Pressure Measuring Devices , 2007, 2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine.

[25]  Yang Lin,et al.  Study of Pulse Wave Velocity Noninvasive Detecting Instrument Based on Radial Artery and Finger Photoplethysmography Pulse Wave , 2008, 2008 International Symposium on Intelligent Information Technology Application Workshops.

[26]  Bin Bin Fu,et al.  Development of a mobile pulse waveform analyzer for cardiovascular health monitoring , 2008, Comput. Biol. Medicine.

[27]  H. Harry Asada,et al.  Cuffless Blood Pressure Monitoring Using Hydrostatic Pressure Changes , 2008, IEEE Transactions on Biomedical Engineering.

[28]  Carmen C. Y. Poon,et al.  An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects , 2009, Cardiovascular engineering.

[29]  Dingchang Zheng,et al.  Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure. , 2009, Journal of biomechanics.

[30]  Koji Oguri,et al.  Cuffless blood pressure estimation by error-correcting output coding method based on an aggregation of AdaBoost with a photoplethysmograph sensor , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[31]  Federico S. Cattivelli,et al.  Noninvasive Cuffless Estimation of Blood Pressure from Pulse Arrival Time and Heart Rate with Adaptive Calibration , 2009, 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks.

[32]  Meir Nitzan,et al.  Automatic noninvasive measurement of systolic blood pressure using photoplethysmography , 2009, Biomedical engineering online.

[33]  SH Song,et al.  Estimation of blood pressure using Photoplethysmography on the wrist , 2009, 2009 36th Annual Computers in Cardiology Conference (CinC).

[34]  Nasrul Humaimi Mahmood,et al.  Pulse Wave Transit Time and Its Relationship with Systolic Blood Pressure , 2010 .

[35]  K. Thanushkodi,et al.  Wavelet based pulse rate and Blood pressure estimation system from ECG and PPG signals , 2011, 2011 International Conference on Computer, Communication and Electrical Technology (ICCCET).

[36]  M. Nitzan,et al.  Automatic noninvasive measurement of arterial blood pressure , 2011, IEEE Instrumentation & Measurement Magazine.

[37]  M. Asif-Ul-Hoque,et al.  Measurement of Blood Pressure Using Photoplethysmography , 2011, 2011 UkSim 13th International Conference on Computer Modelling and Simulation.

[38]  A. F. Mitul,et al.  Development of a noninvasive continuous blood pressure measurement and monitoring system , 2012, 2012 International Conference on Informatics, Electronics & Vision (ICIEV).

[39]  Jung Kim,et al.  Artifacts in wearable photoplethysmographs during daily life motions and their reduction with least mean square based active noise cancellation method , 2012, Comput. Biol. Medicine.

[40]  Domenico Grimaldi,et al.  A Neural Network-based method for continuous blood pressure estimation from a PPG signal , 2013, 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[41]  Shivaraman Ilango,et al.  A Non-Invasive Blood Pressure Measurement using Android Smart Phones , 2014 .