4D-CBCT reconstruction using MV portal imaging during volumetric modulated arc therapy.

BACKGROUND Recording target motion during treatment is important for verifying the irradiated region. Recently, cone-beam computed tomography (CBCT) reconstruction from portal images acquired during volumetric modulated arc therapy (VMAT), known as VMAT-CBCT, has been investigated. In this study, we developed a four-dimensional (4D) version of the VMAT-CBCT. MATERIALS AND METHODS The MV portal images were sequentially acquired from an electronic portal imaging device. The flex, background, monitor unit, field size, and multi-leaf collimator masking corrections were considered during image reconstruction. A 4D VMAT-CBCT requires a respiratory signal during image acquisition. An image-based phase recognition (IBPR) method was performed using normalised cross correlation to extract a respiratory signal from the series of portal images. RESULTS Our original IBPR method enabled us to reconstruct 4D VMAT-CBCT with no external devices. We confirmed that 4D VMAT-CBCT was feasible for two patients and in good agreement with in-treatment 4D kV-CBCT. CONCLUSION The visibility of the anatomy in 4D VMAT-CBCT reconstruction for lung cancer patients has the potential of using 4D VMAT-CBCT as a tool for verifying relative positions of tumour for each respiratory phase.

[1]  M. V. van Herk,et al.  Replacing pretreatment verification with in vivo EPID dosimetry for prostate IMRT. , 2007, International journal of radiation oncology, biology, physics.

[2]  Hideomi Yamashita,et al.  Verification of in-treatment tumor position using kilovoltage cone-beam computed tomography: a preliminary study. , 2007, International journal of radiation oncology, biology, physics.

[3]  P. Lambin,et al.  A literature review of electronic portal imaging for radiotherapy dosimetry. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  S Webb,et al.  CT reconstruction from portal images acquired during volumetric-modulated arc therapy , 2010, Physics in medicine and biology.

[5]  Steve B. Jiang,et al.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. , 2007, Medical physics.

[6]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[7]  Hideomi Yamashita,et al.  First clinical cone-beam CT imaging during volumetric modulated arc therapy. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  Arthur L Boyer,et al.  Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  Josh Star-Lack,et al.  Acquisition of MV-scatter-free kilovoltage CBCT images during RapidArc™ or VMAT. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  Fang-Fang Yin,et al.  On-board four-dimensional digital tomosynthesis: first experimental results. , 2008, Medical physics.

[11]  Toshikazu Imae,et al.  Cone beam computed tomography data acquisition during VMAT delivery with subsequent respiratory phase sorting based on projection image cross-correlation. , 2011, Journal of radiation research.

[12]  Timothy D. Solberg,et al.  The Role of In-Room kV X-Ray Imaging for Patient Setup and Target Localization , 2009 .

[13]  Steve Webb,et al.  Obtaining breathing patterns from any sequential thoracic x-ray image set , 2009, Physics in medicine and biology.

[14]  Tinsu Pan,et al.  Slow gantry rotation acquisition technique for on-board four-dimensional digital tomosynthesis. , 2010, Medical physics.

[15]  Philippe Lambin,et al.  Routine individualised patient dosimetry using electronic portal imaging devices. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  Lei Zhu,et al.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order methoda). , 2010, Medical physics.

[17]  Nobuhiro Tsukamoto,et al.  A comparison of the respiratory signals acquired by different respiratory monitoring systems used in respiratory gated radiotherapy. , 2010, Medical physics.