Building integration of domestic solar combi-systems: the importance of managing the distribution pipework

This paper examines the inextricable link between the performance of solar combi-systems coupled with under-floor radiant heating and the architectural design of buildings where such systems may be used. It focuses on the impact of building fabric, area and rooms’ layout on both the system‘s performance and thermal comfort. The building integration of the distribution pipework is sensitively examined through an experimental analysis of a case study; a residence in South Europe, using dynamic thermal simulation and numerical modeling. It is found that pipe losses - regarded both as energy wastage and heat gains to the space - can be significant but also controlled if the pipe network is carefully planned. The results show that collector loop losses can be comparable to tank losses for most of the year or even higher in some months, and that the management of the collector loop piping length can be more effective in controlling these losses than improving the pipes’ insulation. The analysis further shows that there are times when distribution losses have the potential to cause noticeable local overheating e.g. long piping length or piping route passing through narrow spaces like corridors and lobbies.

[1]  Georgios Martinopoulos,et al.  Thirty years of domestic solar hot water systems use in Greece – energy and environmental benefits – future perspectives , 2010 .

[2]  Georgios Martinopoulos,et al.  Active solar heating systems for energy efficient buildings in Greece: A technical economic and environmental evaluation , 2014 .

[3]  Koray Ulgen,et al.  Energy analysis of Solar Combisystems in Turkey , 2012 .

[4]  Dagnija Blumberga,et al.  Compact Solar Combisystem for an Apartment Building , 2010 .

[5]  Felix A. Peuser,et al.  Solar Thermal Systems: Successful Planning and Construction , 2002 .

[6]  Andreas K. Athienitis,et al.  A prototype photovoltaic/thermal system integrated with transpired collector , 2011 .

[7]  Jean-Christophe Hadorn,et al.  SYSTEM DESIGNS AND PERFORMANCE OF SOLAR COMBISYSTEMS Status report of Task 26 of the IEA Solar Heating and Cooling Programme , 2002 .

[8]  Armando C. Oliveira,et al.  Evaluation of a solar thermal system using building louvre shading devices , 2006 .

[9]  Werner Weiss,et al.  Solar Heating Systems for Houses : A Design Handbook for Solar Combisystems , 2003 .

[10]  Kwang-Woo Kim,et al.  Strategies for flow rate balancing in radiant floor heating systems , 2008 .

[11]  Hasan Karabay,et al.  A numerical investigation of fluid flow and heat transfer inside a room for floor heating and wall heating systems , 2013 .

[12]  Saffa Riffat,et al.  Building integrated solar thermal collectors – A review , 2015 .

[13]  Deutsche Gesellschaft für Sonnenenergie Planning and installing solar thermal systems : a guide for installers, architects and engineers , 2010 .

[14]  Jean-Louis Scartezzini,et al.  On the feasibility of colored glazed thermal solar collectors based on thin film interference filters , 2004 .

[15]  Lucia Fontana,et al.  Thermal performance of radiant heating floors in furnished enclosed spaces , 2011 .

[16]  Deutsche Gesellschaft Fur Sonnenenergie Dgs Planning and Installing Solar Thermal Systems: A Guide for Installers, Architects and Engineers , 2013 .

[17]  Onorio Saro,et al.  Massive Solar-Thermal Collectors: A critical literature review , 2012 .

[18]  Donald Kneale Alexander,et al.  HTB2: A flexible model for dynamic building simulation , 1990 .

[19]  Bijan Farhanieh,et al.  A parametric study on radiant floor heating system performance , 2006 .

[20]  Georgios Martinopoulos,et al.  Solar energy systems potential for nearly net zero energy residential buildings , 2015 .

[21]  Yvan J. Beliveau,et al.  Design, construction and performance prediction of integrated solar roof collectors using finite element analysis , 2007 .

[22]  Luis E. Juanicó,et al.  A new design of roof-integrated water solar collector for domestic heating and cooling , 2008 .

[23]  Phillip John Jones,et al.  Case study of zero energy house design in UK , 2009 .

[24]  Anne Grete Hestnes,et al.  Building Integration Of Solar Energy Systems , 1999 .

[25]  Xiaoqiang Zhai,et al.  Design and performance of the solar-powered floor heating system in a green building , 2009 .

[26]  P. Lund Sizing and applicability considerations of solar combisystems , 2005 .

[27]  J. K. Kaldellis,et al.  Feasibility analysis of domestic solar water heating systems in Greece , 2005 .

[28]  C. Giannakopoulos,et al.  Modelling the energy demand projection of the building sector in Greece in the 21st century , 2012 .

[29]  KN Rhee,et al.  Simulation study on hydronic balancing to improve individual room control for radiant floor heating system , 2010 .

[30]  R. Judkoff,et al.  IEA BESTEST Multi-Zone Non-Airflow In-Depth Diagnostic Cases: Preprint , 2011 .