Quantitative Analysis of Serum Procollagen Type I C-Terminal Propeptide by Immunoassay on Microchip

Background Sandwich enzyme-linked immunosorbent assay (ELISA) is one of the most frequently employed assays for clinical diagnosis, since this enables the investigator to identify specific protein biomarkers. However, the conventional assay using a 96-well microtitration plate is time- and sample-consuming, and therefore is not suitable for rapid diagnosis. To overcome these drawbacks, we performed a sandwich ELISA on a microchip. Methods and Findings The microchip was made of cyclic olefin copolymer with straight microchannels that were 300 µm wide and 100 µm deep. For the construction of a sandwich ELISA for procollagen type I C-peptide (PICP), a biomarker for bone formation, we used a piezoelectric inkjet printing system for the deposition and fixation of the 1st anti-PICP antibody on the surface of the microchannel. After the infusion of the mixture of 2.0 µl of peroxidase-labeled 2nd anti-PICP antibody and 0.4 µl of sample to the microchannel and a 30-min incubation, the substrate for peroxidase was infused into the microchannel; and the luminescence intensity of each spot of 1st antibody was measured by CCD camera. A linear relationship was observed between PICP concentration and luminescence intensity over the range of 0 to 600 ng/ml (r2 = 0.991), and the detection limit was 4.7 ng/ml. Blood PICP concentrations of 6 subjects estimated from microchip were compared with results obtained by the conventional method. Good correlation was observed between methods according to simple linear regression analysis (R2 = 0.9914). The within-day and between-days reproducibilities were 3.2–7.4 and 4.4–6.8%, respectively. This assay reduced the time for the antigen-antibody reaction to 1/6, and the consumption of samples and reagents to 1/50 compared with the conventional method. Conclusion This assay enabled us to determine serum PICP with accuracy, high sensitivity, time saving ability, and low consumption of sample and reagents, and thus will be applicable to clinic diagnosis.

[1]  S. Krane,et al.  Procollagen type I carboxy‐terminal extension peptide in serum as a marker of collagen biosynthesis in bone. Correlation with iliac bone formation rates and comparison with total alkaline phosphatase , 1987, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[2]  J. Risteli,et al.  Use of a marker of collagen formation in osteoporosis studies , 2007, Calcified Tissue International.

[3]  Paul Yager,et al.  Demonstration of multi-analyte patterning using piezoelectric inkjet printing of multiple layers. , 2008, Analytica chimica acta.

[4]  Noritada Kaji,et al.  Determination of human blood glucose levels using microchip electrophoresis , 2007, Electrophoresis.

[5]  Takehiko Kitamori,et al.  Microchip-based cell analysis and clinical diagnosis system. , 2008, Lab on a chip.

[6]  Piia von Lode,et al.  Point-of-care immunotesting: approaching the analytical performance of central laboratory methods. , 2005, Clinical biochemistry.

[7]  Takehiko Kitamori,et al.  Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection. , 2004, Lab on a chip.

[8]  Piia von Lode,et al.  Point-of-care immunotesting: approaching the analytical performance of central laboratory methods. , 2005 .

[9]  Massimo Leone,et al.  Integration between the Tele-Cardiology Unit and the central laboratory: methodological and clinical evaluation of point-of-care testing cardiac marker in the ambulance , 2006, Clinical chemistry and laboratory medicine.

[10]  Takehiko Kitamori,et al.  Biological cells on microchips: new technologies and applications. , 2007, Biosensors & bioelectronics.

[11]  D. T. Wong,et al.  Human body fluid proteome analysis , 2006, Proteomics.

[12]  N. Anderson,et al.  The Human Plasma Proteome , 2002, Molecular & Cellular Proteomics.

[13]  Anand Doraiswamy,et al.  Inkjet printing of bioadhesives. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[14]  T. Tachi,et al.  Microchip-based Homogeneous Immunoassay Using a Cloned Enzyme Donor , 2009, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[15]  K. Hyde,et al.  Guidelines for point‐of‐care testing: haematology , 2008, British journal of haematology.

[16]  J. Beck,et al.  Enzyme immunoassays with special reference to ELISA techniques. , 1978, Journal of clinical pathology.

[17]  Noritada Kaji,et al.  Online preconcentration by transient isotachophoresis in linear polymer on a poly(methyl methacrylate) microchip for separation of human serum albumin immunoassay mixtures. , 2007, Analytical chemistry.

[18]  T Kitamori,et al.  Integration of an immunosorbent assay system: analysis of secretory human immunoglobulin A on polystyrene beads in a microchip. , 2000, Analytical chemistry.

[19]  Y. Niitsu,et al.  Diagnostic value of measurement of serum type I procollagen carboxy terminal peptides in patients with scirrhous carcinoma of the stomach. , 1991, Gut.

[20]  D. Citterio,et al.  Inkjet-printed microfluidic multianalyte chemical sensing paper. , 2008, Analytical chemistry.

[21]  Keith Dudley Short protocols in molecular biology , 1990 .

[22]  Tomoyuki Yasukawa,et al.  Flow sandwich-type immunoassay in microfluidic devices based on negative dielectrophoresis. , 2007, Biosensors & bioelectronics.

[23]  T. Porstmann,et al.  Enzyme immunoassay techniques. An overview. , 1992, Journal of immunological methods.

[24]  Takehiko Kitamori,et al.  Microchip‐based immunoassay system with branching multichannels for simultaneous determination of interferon‐γ , 2002, Electrophoresis.

[25]  Stanislas Leibler,et al.  Printing Multistrain Bacterial Patterns with a Piezoelectric Inkjet Printer , 2007, PloS one.

[26]  Takehiko Kitamori,et al.  A micro-ELISA system for the rapid and sensitive measurement of total and specific immunoglobulin E and clinical application to allergy diagnosis. , 2009, Lab on a chip.

[27]  Dimitra N. Stratis-Cullum,et al.  Investigation of microfabrication of biological sample arrays using piezoelectric and bubble-jet printing technologies , 2004 .

[28]  N. Kaji,et al.  Accurate quantitation of salivary and pancreatic amylase activities in human plasma by microchip electrophoretic separation of the substrates and hydrolysates coupled with immunoinhibition , 2008, Electrophoresis.

[29]  Roger J Narayan,et al.  Piezoelectric inkjet printing of a cross‐hatch immunoassay on a disposable nylon membrane , 2009, Biotechnology journal.

[30]  Noritada Kaji,et al.  Microchip-based homogeneous immunoassay using fluorescence polarization spectroscopy. , 2009, Lab on a chip.

[31]  T Kitamori,et al.  Determination of carcinoembryonic antigen in human sera by integrated bead-bed immunoassay in a microchip for cancer diagnosis. , 2001, Analytical chemistry.

[32]  P. St-Louis Status of point-of-care testing: promise, realities, and possibilities. , 2000, Clinical biochemistry.

[33]  J. Tissot,et al.  Recent advances in blood‐related proteomics , 2005, Proteomics.