Integrated Control of Heat Pumps

The purpose of the work presented in this thesis is to investigate the potential and prerequisites for improved energy efficiency of heat pump systems using efficient components and proper methods for optimisation of operation. The background is that several investigations have reported on possibilities for increased energy efficiency of heat pumps if variable-speed capacity control is used instead of conventional on/off control. Further improvements are possible if variable speed pumps or fans and electronically controlled expansion valves are used as well. To take full advantage of these new controls they should be properly co-ordinated and optimised. In this work, a measuring system consisting of three temperature sensors and two pressure sensors was used for on-line measurement of the coefficient of performance in an experimental investigation. Knowledge of the performance provides a basis for self-optimising closed-loop control. The measurement system can also be used for Fault Detection and Diagnosis (FDD) and Performance Indication and thus contribute to an integrated control system. The Nelder-Mead simplex method was applied for on-line optimisation. The method was evaluated by computer simulations and shows promising results. It was possible to find the optimal set point, maximising COP, and the method could also handle soft constraints, such as a desired set point for the heating capacity. The potential of variable-speed capacity control was investigated both by laboratory tests and annual energy savings calculations. The laboratory tests were made on a brine-to-water heat pump with a variable-speed piston compressor and an electronic expansion valve. The results from the tests showed a decrease in efficiency when applying variable-speed capacity control to the compressor when compared to conventional on/off control. Analyses indicate that this is due to losses in the frequency converter and increased losses within the compressor, most likely in the electric motor. The electronic valve gave only a marginal increase in efficiency compared to a conventional thermostatic expansion valve. Using these test results as a basis, the possible annual energy savings were calculated. This analysis indicates that there exists an energy saving potential also for variable-speed controlled brine-to-water heat pumps but it requires product development mainly of the compressors. A conservative estimate indicates savings of 10 % compared to on/off control.

[1]  Rita Mastrullo,et al.  Experimental evaluation of electronic and thermostatic expansion valves performances using R22 and R407C , 2002 .

[2]  Per Fahlén Frosting and Defrosting of Air-Coils , 1996 .

[3]  Savvas A. Tassou,et al.  Dynamic mode performance evaluation and energy analysis of mains and inverter driven refrigeration compressors , 1997 .

[4]  H. Harry Asada,et al.  Multivariable control of vapor compression systems , 1998 .

[5]  H. Holdack-Janssen,et al.  Continuous and Discontinuous Capacity Control for High Speed Refrigeration Compressors , 1984 .

[6]  Arne Jakobsen,et al.  Development of Energy Optimal Capacity Control in Refrigeration Systems , 2000 .

[7]  Savvas A. Tassou,et al.  Comparison of the performance of capacity controlled and conventional on/off controlled heat pumps , 1983 .

[8]  P. G. Jolly,et al.  Fuzzy Control of Superheat in Container Refrigeration using an Electronic Expansion Valve , 1997 .

[9]  Mordecai Avriel,et al.  Nonlinear programming , 1976 .

[10]  James E. Braun,et al.  Evaluating the Performance of a Fault Detection and Diagnostic System for Vapor Compression Equipment , 1998 .

[11]  A. C Cleland,et al.  Polynomial curve-fits for refrigerant thermodynamic properties: extension to include R134a , 1994 .

[12]  Janos Gertler,et al.  Fault detection and diagnosis in engineering systems , 1998 .

[13]  P. Haberschill,et al.  The transient response of an evaporator fed through an electronic expansion valve , 1997 .

[14]  J. E. Braun,et al.  Reducing Operating Costs with Optimal Maintenance Scheduling , 1994 .

[15]  Chun H. Cho,et al.  Computer optimization of refrigeration systems in a textile plant: A case history , 1982, Autom..

[16]  Sanford Klein,et al.  Methodologies for optimal control of chilled water systems without storage , 1989 .

[17]  Per Fahlén,et al.  Ground-source heat pumps - Recharging of boreholes by exhaust-air coils , 2000 .

[18]  S. Touber,et al.  Influence of the Expansion Valve on the Evaporator Performance , 1986 .

[19]  Savvas A. Tassou,et al.  Effect of refrigerant flow control on the thermodynamic performances of reciprocating chillers , 1993 .

[20]  Savvas A. Tassou,et al.  Investigation of the effects of thermostatic and electronic expansion valves on the steady-state and transient performance of commercial chillers. , 1993 .

[21]  Savvas A. Tassou,et al.  VARIABLE-SPEED CAPACITY CONTROL IN REFRIGERATION SYSTEMS , 1996 .

[22]  Giancarlo Scalabrin,et al.  Experimental thermodynamic analysis of a variable-speed open reciprocating refrigeration compressor , 1994 .

[23]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[24]  Savvas A. Tassou,et al.  An economic comparison of a fixed speed, a two speed, and a variable speed vapour compression heat pump , 1984 .

[25]  A. C Cleland,et al.  Computer subroutines for rapid evaluation of refrigerant thermodynamic properties , 1986 .

[26]  J. E. Braun,et al.  An Optimal Maintenance Scheduler , 1994 .

[27]  Todd M. Rossi,et al.  A Statistical, Rule-Based Fault Detection and Diagnostic Method for Vapor Compression Air Conditioners , 1997 .

[28]  S. Tassou,et al.  Investigation of the Effect of Inverters on the Power Supply and the Performance of Variable Speed Refrigeration Systems , 1994 .

[29]  E.Pereira Perreira,et al.  Performance Analysis of Capacity Control Devices for Heat Pump Reciprocating Compressors , 1993 .

[30]  P. G. Jolly,et al.  Intelligent Control to Reduce Superheat Hunting and Optimize Evaporator Performance in Container Refrigeration , 2000 .

[31]  Savvas A. Tassou,et al.  Comparative performance evaluation of positive displacement compressors in variable-speed refrigeration applications , 1998 .