Microfabricated cantilevers for measurement of subcellular and molecular forces

We present two new microfabricated cantilever-beam force transducers. The transducers were fabricated from thin silicon-nitride films, and were used respectively to measure forces generated by two small-muscle preparations: the single myofibril, and the single actin filament in contact with a myosin-coated surface. A simple resonance method was developed to characterize the transducers. Because of the high reproducibility of lever dimensions and the consistency of the modulus of elasticity, few calibration measurements sufficed to characterize the stiffness of all the levers on a single wafer.

[1]  W. Newell Miniaturization of tuning forks. , 1968, Science.

[2]  K. Petersen,et al.  Young’s modulus measurements of thin films using micromechanics , 1979 .

[3]  T. Iwazumi,et al.  High-speed ultrasensitive instrumentation for myofibril mechanics measurements. , 1987, The American journal of physiology.

[4]  J. Koskinen,et al.  Silicon nitride fibers using micro fabrication methods , 1988 .

[5]  Toshio Yanagida,et al.  Force measurements by micromanipulation of a single actin filament by glass needles , 1988, Nature.

[6]  H. Iwamoto,et al.  Simultaneous recordings of force and sliding movement between a myosin-coated glass microneedle and actin cables in vitro. , 1989, Proceedings of the National Academy of Sciences of the United States of America.

[7]  Timothy P. Weihs,et al.  Measuring stiffnesses and residual stresses of silicon nitride thin films , 1990 .

[8]  A. Steckenborn,et al.  Determination of Young's moduli of micromechanical thin films using the resonance method , 1992 .

[9]  M. Stadtmüeller Mechanical Stress of CVD‐Dielectrics , 1992 .

[10]  S. Ishiwata,et al.  Spontaneous oscillation of tension and sarcomere length in skeletal myofibrils. Microscopic measurement and analysis. , 1992, Biophysical journal.

[11]  L.A. Fearn,et al.  An optical fiber transducer for single myofibril force measurement , 1993, IEEE Transactions on Biomedical Engineering.

[12]  S. Ishiwata,et al.  Spontaneous tension oscillation (SPOC) of muscle fibers and myofibrils minimum requirements for SPOC. , 1993, Advances in experimental medicine and biology.

[13]  E. Homsher,et al.  Myosin-specific adaptations of the motility assay. , 1993, Methods in cell biology.

[14]  J. Spudich,et al.  In vitro methods for measuring force and velocity of the actin-myosin interaction using purified proteins. , 1993, Methods in cell biology.

[15]  C. J. Drummond,et al.  Characterisation of the Mechanical Properties of Thin Film Cantilevers with the Atomic Force Microscope , 1995 .

[16]  T. Yanagida,et al.  Multiple- and single-molecule analysis of the actomyosin motor by nanometer-piconewton manipulation with a microneedle: unitary steps and forces. , 1996, Biophysical journal.