Thermal analysis for a double glazing unit with and without a solar control film (SnS-CuxS) for using in hot climates

Abstract In this paper the thermal analysis by natural convection of a double glazing unit (DGU) is presented. One of the sheet glasses may or may not have a solar control film (SnS–Cu x S) on its surface. Solar radiation falls on the outside surface of the DGU at 32 °C, the opposite sheet glass interacts with the inside environment at 24 °C. The governing equations of mass, momentum and energy of the air enclosed between the two sheet glasses are solved, as well as the heat conduction equation for both sheet glasses. The effect of varying the separation distance between the glasses (1.0 ≤  b (cm) ≤ 10.0) and the incident solar radiation is analyzed (500.0 ≤  G (W/m 2 ) ≤ 800.0). From the results, it was found that in order to reduce heat gains towards the inside environment, the optimal separation distance between the sheet glasses was b  ≥ 6.0 cm. It was also observed that, the use of a solar control film in this type of system (double glazing unit) is highly recommended; due to energy gain was reduced by 55% compared to the traditional DGU without solar control film.

[1]  Mats Sandberg,et al.  Thermal analysis of super insulated windows (numerical and experimental investigations) , 1999 .

[2]  C. Gueymard,et al.  Spectral effects on the transmittance, solar heat gain, and performance rating of glazing systems , 2009 .

[3]  K. Ismail,et al.  Two-dimensional model for the double glass naturally ventilated window , 2005 .

[4]  A. Oliva,et al.  Numerical analysis of the thermal behaviour of glazed ventilated facades in Mediterranean climates. Part II: applications and analysis of results , 2003 .

[5]  Thermal performance of solar control coatings: a mathematical model and its experimental verification , 1998 .

[6]  Wei He,et al.  Use of ventilated solar screen window in warm climate , 2006 .

[7]  Kamal Abdel Radi Ismail,et al.  Comparison between PCM filled glass windows and absorbing gas filled windows , 2008 .

[8]  Sašo Medved,et al.  Heat transfer through a double pane window with an insulation screen open at the top , 1998 .

[9]  Orhan Aydin,et al.  Conjugate heat transfer analysis of double pane windows , 2006 .

[10]  Adrian Bejan,et al.  Natural Convection in a Vertical Enclosure With Internal Permeable Screen , 1991 .

[11]  Kamal Abdel Radi Ismail,et al.  Modeling and simulation of a simple glass window , 2003 .

[12]  M. Modest Radiative heat transfer , 1993 .

[13]  J. P. V. Doormaal,et al.  ENHANCEMENTS OF THE SIMPLE METHOD FOR PREDICTING INCOMPRESSIBLE FLUID FLOWS , 1984 .

[14]  P K Nair,et al.  SnS-CuxS thin film combination: a desirable solar control coating for architectural and automobile glazings , 1991 .

[15]  Kamal Abdel Radi Ismail,et al.  A comparative study of naturally ventilated and gas filled windows for hot climates , 2009 .

[16]  Refrigerating ASHRAE handbook and product directory /published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc , 1977 .

[17]  R. Almanza,et al.  Solar filters based on iron oxides used as efficient windows for energy savings , 2007 .

[18]  I. Pop,et al.  Thermal Radiation Effect on Fully Developed Mixed Convection Flow in a Vertical Channel , 2007 .

[19]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[20]  K. F. Fong,et al.  Thermal performance of natural airflow window in subtropical and temperate climate zones – A comparative study , 2009 .

[21]  A. Oliva,et al.  Numerical analysis of the thermal behaviour of ventilated glazed facades in Mediterranean climates. Part I: development and validation of a numerical model , 2003 .

[22]  Kamal Abdel Radi Ismail,et al.  Simplified model for a ventilated glass window under forced air flow conditions , 2006 .

[23]  Orhan Aydin,et al.  Determination of optimum air-layer thickness in double-pane windows , 2000 .

[24]  Michael Rubin,et al.  Calculating heat transfer through windows , 1982 .

[25]  G. D. Davis Natural convection of air in a square cavity: A bench mark numerical solution , 1983 .

[26]  Zhang Lin,et al.  Innovative solar windows for cooling-demand climate , 2010 .

[27]  J. Xamán,et al.  Effect of Heat Conduction of SnS-Cu x S Solar Control Coated Semitransparent Wall on Turbulent Natural Convection in a Square Cavity , 2006 .

[28]  Carl M. Lampert,et al.  HEAT-MIRROR COATINGS FOR ENERGY-CONSERVING WINDOWS , 1981 .

[29]  P. K. Nair,et al.  Solar cells with Sb2S3 absorber films , 2009 .

[30]  J. O. Aguilar,et al.  Optical and mechanical characteristics of clear and solar control laminated glass using zinc sulphide and copper sulphide thin films , 2005 .

[31]  Heat Transfer Through a Duovent Glass With Chemically Deposited Solar Control Coating , 2000 .