Thrombus formation at the surface of guide-wire models: effects of heparin-releasing or heparin-exposing surface coatings.
暂无分享,去创建一个
[1] S. Béguin,et al. Thrombin generation for the control of heparin treatment, comparison with the activated partial thromboplastin time , 2004, Journal of thrombosis and haemostasis : JTH.
[2] L. Koole,et al. Coils and tubes releasing heparin. Studies on a new vascular graft prototype. , 2004, Biomaterials.
[3] A. Colombo,et al. Intraprocedural Stent Thrombosis During Implantation of Sirolimus-Eluting Stents , 2004, Circulation.
[4] H. Hemker,et al. Thrombin generation assays: accruing clinical relevance , 2004, Current opinion in hematology.
[5] W. Ouwehand,et al. Platelet receptor interplay regulates collagen-induced thrombus formation in flowing human blood. , 2004, Blood.
[6] D. Ku,et al. A Novel Method for Efficient Drug Delivery , 1998, Annals of Biomedical Engineering.
[7] L. Koole,et al. Heparin-releasing intravascular guidewires. , 2002, Medical device technology.
[8] F. Gobeil,et al. Thrombus formation on guide wires during routine PTCA procedures: a scanning electron microscopic evaluation. , 2002, The Canadian journal of cardiology.
[9] L. Koole,et al. Heparin release from slippery-when-wet guide wires for intravascular use. , 2002, Journal of biomedical materials research.
[10] F. H. van der Veen,et al. Metallic wires with an adherent lubricious and blood-compatible polymeric coating and their use in the manufacture of novel slippery-when-wet guidewires: possible applications related to controlled local drug delivery. , 1999, Journal of biomedical materials research.
[11] A. Moreyra,et al. Effect of prolonged blood contact time on deposition of cellular and amorphous material on teflon-coated guidewires: a scanning electron microscopy study. , 1996, Catheterization and cardiovascular diagnosis.
[12] H. Hemker,et al. Design and synthesis of thrombin substrates with modified kinetic parameters. , 1995, Thrombosis research.
[13] Y. Ikada,et al. Simple method for platelet counting. , 1995, Biomaterials.
[14] P. Grayburn,et al. In vivo thrombus formation on a guidewire during intravascular ultrasound imaging: evidence for inadequate heparinization. , 1991, Catheterization and cardiovascular diagnosis.
[15] D. Seidenwurm,et al. Thrombogenicity of Teflon versus copolymer-coated guidewires: evaluation with scanning electron microscopy. , 1989, AJNR. American journal of neuroradiology.
[16] D. Kido,et al. The Role of Catheters and Guidewires in the Production of Angiographic Thromboembolic Complications , 1988, Investigative radiology.
[17] H. Hemker,et al. Handbook of synthetic substrates : for the coagulation and fibrinolytic system , 1983 .
[18] P. K. Smith,et al. Colorimetric method for the assay of heparin content in immobilized heparin preparations. , 1980, Analytical biochemistry.