Comparison of automated office blood pressure measurement with 24-hour ambulatory blood pressure measurement

Abstract Purpose Although 24-hour ambulatory blood pressure measurement (24-h ABPM) is the most important method to establish true hypertension, in clinical practice often repeated automated office blood pressure (AOBP) measurements are used because of convenience and lower costs. We aimed to assess the agreement rate between a 30 and 60 min AOBP and 24-h ABPM. Materials and methods Patients with known hypertension (cohort 1) and patients visiting the neurology outpatient clinic after minor stroke or transient ischaemic attack (cohort 2) were selected. We performed AOBP for 30–60 min at 5-min intervals followed by 24-h ABPM and calculated average values of both measurements. Agreement between the two methods was studied with McNemar and Bland–Altman plots with a clinically relevant limit of agreement of ≤10 mm Hg difference in systolic BP. Results Our final cohort consisted of 135 patients from cohort 1 and 72 patients from cohort 2. We found relatively low agreement based on the clinical relevant cut-off value; 64.7% of the measurements were within the limits of agreement for 24-h systolic and 50.2% for 24-h diastolic. This was 61.4% for daytime systolic and 56.6% for daytime diastolic. In 73.5% of the patients, both methods led to the same diagnosis of either being hypertensive or non-hypertensive. This resulted in a significant difference between the methods to determine the diagnosis of hypertension (p < 0.0001). Conclusion We conclude that 30–60 min AOBP measurements cannot replace a 24-h ABPM and propose to perform 24-h ABPM at least on a yearly basis to confirm AOBP measurements.

[1]  J. Filipovský,et al.  Comparison of three office blood pressure measurement techniques and their effect on hypertension prevalence in the general population. , 2019, Journal of hypertension.

[2]  F. Veglio,et al.  COMPARISON OF AUTOMATED OFFICE BLOOD PRESSURE WITH OFFICE AND OUT-OF-OFFICE MEASUREMENT TECHNIQUES , 2019, Journal of Hypertension.

[3]  J. Kaczorowski,et al.  Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis , 2019, JAMA internal medicine.

[4]  Thomas Kahan,et al.  [2018 ESC/ESH Guidelines for the management of arterial hypertension]. , 2019, Kardiologia polska.

[5]  P. Whelton,et al.  Rationale for Ambulatory and Home Blood Pressure Monitoring Thresholds in the 2017 American College of Cardiology/American Heart Association Guideline. , 2019, Hypertension.

[6]  G. Lip,et al.  2018 ESC/ESH Guidelines for the management of arterial hypertension. , 2018, European heart journal.

[7]  P. Whelton,et al.  Blood Pressure Measurement in SPRINT (Systolic Blood Pressure Intervention Trial) , 2018, Hypertension.

[8]  V. Papademetriou,et al.  Attended and Unattended Automated Office Blood Pressure Measurements Have Better Agreement With Ambulatory Monitoring Than Conventional Office Readings , 2018, Journal of the American Heart Association.

[9]  M. Ruzicka,et al.  Are Automated Blood Pressure Monitors Comparable to Ambulatory Blood Pressure Monitors? A Systematic Review and Meta-analysis. , 2017, The Canadian journal of cardiology.

[10]  Yuli Huang,et al.  White-coat hypertension is a risk factor for cardiovascular diseases and total mortality , 2017, Journal of hypertension.

[11]  G. Parati,et al.  SPRINT Blood Pressure: Sprinting Back to Smirk's Basal Blood Pressure? , 2017, Hypertension.

[12]  Otto Mayer,et al.  Automated compared to manual office blood pressure and to home blood pressure in hypertensive patients , 2016, Blood pressure.

[13]  L. Pierard A Randomized Trial of Intensive versus Standard Blood-Pressure Control. , 2016, The New England journal of medicine.

[14]  C. Escobar Cervantes,et al.  [A randomized trial of intensive versus standard blood pressure control]. , 2016, Semergen.

[15]  D. Brouillard,et al.  Automated office blood pressure – being alone and not location is what matters most , 2015, Blood pressure monitoring.

[16]  D. Giavarina Understanding Bland Altman analysis , 2015, Biochemia medica.

[17]  Gianfranco Parati,et al.  Ambulatory blood pressure measurement: what is the international consensus? , 2013, Hypertension.

[18]  M. Ruzicka,et al.  BpTRUth: do automated blood pressure monitors outperform mercury? , 2013, Journal of the American Society of Hypertension : JASH.

[19]  Michael Böhm,et al.  2013 ESH/ESC Guidelines for the management of arterial hypertension: the Task Force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC). , 2007, Journal of hypertension.

[20]  T. Psaltopoulou,et al.  Circadian variation of blood pressure and heart rate in normotensives, white-coat, masked, treated and untreated hypertensives. , 2012, Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese.

[21]  Giuseppe Mancia,et al.  Short- and long-term blood pressure variability: present and future. , 2012, Hypertension.

[22]  M. Lamarre-Cliche,et al.  Comparative assessment of four blood pressure measurement methods in hypertensives. , 2011, The Canadian journal of cardiology.

[23]  C. van Weel,et al.  A Novel Approach to Office Blood Pressure Measurement: 30-Minute Office Blood Pressure vs Daytime Ambulatory Blood Pressure , 2011, The Annals of Family Medicine.

[24]  B Waeber,et al.  European Society of Hypertension Practice Guidelines for home blood pressure monitoring , 2010, Journal of Human Hypertension.

[25]  R. Qureshi,et al.  Validation of Datascope Accutorr Plus™ using British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) protocol guidelines. , 2010, Journal of the Saudi Heart Association.

[26]  A. Kiss,et al.  Use of automated office blood pressure measurement to reduce the white coat response , 2009, Journal of hypertension.

[27]  Pierre-François Plouin,et al.  Masked hypertension: a systematic review. , 2008, Journal of hypertension.

[28]  B. Culleton,et al.  Performance of the automated BpTRU™ measurement device in the assessment of white-coat hypertension and white-coat effect , 2006, Blood pressure monitoring.

[29]  J. Swieten Interobserver Agreement for the Assessment of Handicap in Stroke Patients , 2005 .

[30]  Sudha Seshadri,et al.  Residual lifetime risk for developing hypertension in middle-aged women and men: The Framingham Heart Study. , 2002, JAMA.

[31]  M. Kikuya,et al.  Prediction of stroke by ambulatory blood pressure monitoring versus screening blood pressure measurements in a general population: the Ohasama study , 2000, Journal of hypertension.

[32]  Andy P. Field,et al.  Discovering Statistics Using SPSS , 2000 .

[33]  F. Mee,et al.  Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society protocol. , 1991, Journal of hypertension.

[34]  T. Pickering,et al.  Elevation of ambulatory systolic blood pressure in hypertensive smokers. A case-control study. , 1991, JAMA.

[35]  R. Bloch,et al.  Interobserver agreement for the assessment of handicap in stroke patients. , 1988, Stroke.

[36]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.