Automated non-coplanar beam direction optimization improves IMRT in SBRT of liver metastasis.

PURPOSE To investigate whether automatically optimized coplanar, or non-coplanar beam setups improve intensity modulated radiotherapy (IMRT) treatment plans for stereotactic body radiotherapy (SBRT) of liver tumors, compared to a reference equi-angular IMRT plan. METHODS For a group of 13 liver patients, an in-house developed beam selection algorithm (Cycle) was used for generation of 3D-CRT plans with either optimized coplanar-, or non-coplanar beam setups. These 10 field, coplanar and non-coplanar setups, and an 11 field, equi-angular coplanar reference setup were then used as input for generation of IMRT plans. For all plans, the PTV dose was maximized in an iterative procedure by increasing the prescribed PTV dose in small steps until further increase was prevented by constraint violation(s). RESULTS For optimized non-coplanar setups, D(PTV, max) increased by on average 30% (range 8-64%) compared to the corresponding reference IMRT plan. Similar increases were observed for D(PTV, 99%) and gEUD(a). For optimized coplanar setups, mean PTV dose increases were only approximately 4%. After re-scaling all plans to the clinically applied dose, optimized non-coplanar configurations resulted in the best sparing of organs at risk (healthy liver, spinal cord, bowel). CONCLUSION Compared to an equi-angular beam setup, computer optimized non-coplanar setups do result in substantial improvements in IMRT plans for SBRT of liver tumors.

[1]  Michael Flentje,et al.  Stereotactic radiotherapy for primary lung cancer and pulmonary metastases: a noninvasive treatment approach in medically inoperable patients. , 2004, International journal of radiation oncology, biology, physics.

[2]  K. Sheng,et al.  Dose as a function of liver volume and planning target volume in helical tomotherapy, intensity-modulated radiation therapy-based stereotactic body radiation therapy for hepatic metastasis. , 2006, International journal of radiation oncology, biology, physics.

[3]  Michael Flentje,et al.  Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  Robert D Timmerman,et al.  A phase I trial of stereotactic body radiation therapy (SBRT) for liver metastases. , 2005, International journal of radiation oncology, biology, physics.

[5]  Edward C Pennington,et al.  Ultrasound-guided extracranial radiosurgery: technique and application. , 2003, International journal of radiation oncology, biology, physics.

[6]  Randall K Ten Haken,et al.  Benefit of using biologic parameters (EUD and NTCP) in IMRT optimization for treatment of intrahepatic tumors. , 2005, International journal of radiation oncology, biology, physics.

[7]  M. McCarter,et al.  Interim analysis of a prospective phase I/II trial of SBRT for liver metastases , 2006, Acta oncologica.

[8]  I. Lax,et al.  Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator. Clinical experience of the first thirty-one patients. , 1995, Acta oncologica.

[9]  Peter C Levendag,et al.  Computer optimization of noncoplanar beam setups improves stereotactic treatment of liver tumors. , 2006, International journal of radiation oncology, biology, physics.

[10]  J. Petersen,et al.  Phase II study on stereotactic body radiotherapy of colorectal metastases , 2006, Acta oncologica.

[11]  P. Storchi,et al.  Constrained treatment planning using sequential beam selection. , 2000, Physics in medicine and biology.

[12]  Michael Flentje,et al.  Stereotactic Radiotherapy of Targets in the Lung and Liver , 2001, Strahlentherapie und Onkologie.

[13]  Ruiguo Liu,et al.  Optimal number of beams for stereotactic body radiotherapy of lung and liver lesions. , 2006, International journal of radiation oncology, biology, physics.

[14]  Eva K. Lee,et al.  Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[15]  P. Levendag,et al.  Target coverage in image-guided stereotactic body radiotherapy of liver tumors. , 2007, International journal of radiation oncology, biology, physics.

[16]  J. Buatti,et al.  Geometrically based optimization for extracranial radiosurgery. , 2004, Physics in medicine and biology.

[17]  L. Xing,et al.  Incorporating prior knowledge into beam orientation optimization in IMRT. , 2002, International journal of radiation oncology, biology, physics.

[18]  L. Marks,et al.  Relationship between the generalized equivalent uniform dose formulation and the Poisson statistics-based tumor control probability model. , 2004, Medical physics.

[19]  E. Woudstra,et al.  Automated beam angle and weight selection in radiotherapy treatment planning applied to pancreas tumors. , 2003, International journal of radiation oncology, biology, physics.

[20]  F. Lohr,et al.  Stereotactic single-dose radiation therapy of liver tumors: results of a phase I/II trial. , 2001, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[21]  Peter C Levendag,et al.  Stereotactic body radiation therapy for primary and metastatic liver tumors: A single institution phase i-ii study , 2006, Acta oncologica.

[22]  Pascal R M Storchi,et al.  PTV dose prescription strategies for SBRT of metastatic liver tumours. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.