Radioactive Source Estimation Using a System of Directional and Non-Directional Detectors

We derive source parameter estimation algorithms based on maximum likelihood estimation (MLE) for a system of non-directional (scintillator) and directional (CZT based Compton) radiation detectors. For multiple non-directional detectors, the joint likelihood of registered counts is maximized to estimate the source parameters. For directional detectors, the well-known List Mode Maximum Likelihood Expectation Maximization (MLEM) algorithm is extended to fuse information from multiple detectors and locate the source in Cartesian coordinates. We then develop multi-sensor fusion algorithms for a system of non-directional and directional detectors by combining MLE and MLEM algorithms. Results are presented which illustrate the behavior and performance of our proposed approaches.

[1]  C. Pilotto,et al.  Networked sensing systems for detecting people carrying radioactive material , 2008, 2008 5th International Conference on Networked Sensing Systems.

[2]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[3]  Yanfeng Du,et al.  GE intelligent personal radiation locator system , 2009, Defense + Commercial Sensing.

[4]  Mark R. Morelande,et al.  Radiological Source Detection and Localisation Using Bayesian Techniques , 2009, IEEE Transactions on Signal Processing.

[5]  Jeffrey A. Fessler,et al.  List-mode maximum likelihood reconstruction of Compton scatter camera images in nuclear medicine , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[6]  D. Stephens,et al.  Detection of moving radioactive sources using sensor networks , 2004, IEEE Transactions on Nuclear Science.

[7]  C. E. Lehner,et al.  4/spl pi/ Compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood , 2004, IEEE Transactions on Nuclear Science.

[8]  D. Rubin,et al.  Maximum likelihood from incomplete data via the EM - algorithm plus discussions on the paper , 1977 .

[9]  Jeffrey A. Fessler,et al.  Improved modeling of system response in list mode EM reconstruction of Compton scatter camera images , 1999 .

[10]  H H Barrett,et al.  List-mode likelihood. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[11]  Arthur B. Maccabe,et al.  Radiation detection with distributed sensor networks , 2004, Computer.

[12]  Zhong He,et al.  4/spl pi/ Compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[13]  Feng Zhang,et al.  4-pi Compton imaging with single 3D position-sensitive CdZnTe detector , 2004, SPIE Optics + Photonics.

[14]  S. Sitharama Iyengar,et al.  Identification of low-level point radioactive sources using a sensor network , 2010, TOSN.

[15]  J. Stein,et al.  Use of CdZnTe detectors in hand-held and portable isotope identifiers to detect illicit trafficking of nuclear material and radioactive sources , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[16]  B. Ristic,et al.  On Localisation of a Radiological Point Source , 2007, 2007 Information, Decision and Control.

[17]  Arun Ross,et al.  Optics and Photonics in Global Homeland Security V and Biometric Technology for Human Identification VI , 2009 .

[18]  D. Torney,et al.  Distributed sensor networks for detection of mobile radioactive sources , 2004, IEEE Transactions on Nuclear Science.

[19]  Yanfeng Du,et al.  4 pi direction sensitive gamma imager with RENA-3 readout ASIC , 2007, SPIE Optical Engineering + Applications.

[20]  Zhong He,et al.  Gamma-ray energy-imaging integrated deconvolution , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.