Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine: a noninvasive, rapid and effective method for coronary flow reserve assessment.

OBJECTIVES The purpose of this study is to evaluate the feasibility in detecting blood flow in the left anterior descending coronary artery (LAD) using transthoracic color Doppler (CD) imaging (in both second harmonic and fundamental mode) along with contrast enhancement and to verify if this new noninvasive method along with adenosine is safe, rapid and effective in assessing coronary flow reserve (CFR). BACKGROUND Feasibility of contrast-enhanced transthoracic Doppler recording (in both second harmonic and fundamental mode) of blood flow velocity in the LAD has not been assessed. Adenosine has a greater vasodilator potency and more favorable kinetics than dipyridamole and thus it can be more suitable for assessing CFR in conjunction with this method. METHODS Sixty-one patients with angiographically patent LAD underwent CD (both in fundamental and harmonic mode) as well as color-guided pulsed wave (PW) Doppler recording of blood flow velocity in the distal LAD before and after intravenous contrast injection. A second group of patients (n = 77), undergoing coronary angiography, was submitted to transthoracic contrast-enhanced PW Doppler recording of blood flow velocity in the LAD using harmonic CD as a guide, at rest and during adenosine-induced hyperemia. RESULTS Harmonic CD along with echo contrast consistently improved blood flow detection in the LAD; the success rate in detecting flow of optimal quality was 88% with this approach, whereas it was 11% and 16% with CD in fundamental mode, respectively, before and after contrast. Pulsed wave Doppler results paralleled those of harmonic CD (p < 0.001 contrast harmonic vs. fundamental). In the second group of patients coronary angiography revealed 0% to <40% stenosis in 24 patients (group I), > or =40% to < or =75% in 17 patients (group II) and >75% stenosis in 34 patients (group III). There was a significant difference in CFR among the three groups of patients; CFR for peak diastolic velocity was (mean +/- SD): 2.88+/-0.7 (group I), 2.09+/-0.5 (group II) and 1.51+/-0.5 cm/s (group II) (p < 0.05 group I vs. both group II and group III; p < 0.05 group II vs. group III). The whole examination took less than 10 min. CONCLUSIONS Contrast-enhanced second harmonic Doppler recording of blood velocity in the LAD is highly feasible and in combination with adenosine it is a rapid, safe and effective method for assessing CFR ratio.

[1]  B. Chaitman,et al.  Correlation of pharmacological 99mTc-sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses. , 1994, Circulation.

[2]  C Caiati,et al.  New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler. , 1999, Circulation.

[3]  S. Iliceto,et al.  Coronary flow dynamics and reserve assessed by transesophageal echocardiography in obstructive hypertrophic cardiomyopathy. , 1994, The American journal of cardiology.

[4]  H. M. Payne,et al.  Validation of A Doppler Guide Wire for Intravascular Measurement of Coronary Artery Flow Velocity , 1992, Circulation.

[5]  Peter N. Burns,et al.  Imaging instrumentation for ultrasound contrast agents , 1997 .

[6]  T. Inoue,et al.  Coronary flow reserve in patients with dilated cardiomyopathy. , 1993, American heart journal.

[7]  Navin C. Nanda,et al.  Advances in Echo Imaging Using Contrast Enhancement , 1997, Springer Netherlands.

[8]  T J Donohue,et al.  Assessing the hemodynamic significance of coronary artery stenoses: analysis of translesional pressure-flow velocity relations in patients. , 1993, Journal of the American College of Cardiology.

[9]  N. Mullani,et al.  Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients. , 1989, Circulation.

[10]  S. Iliceto,et al.  Improved Doppler detection of proximal left anterior descending coronary artery stenosis after intravenous injection of a lung-crossing contrast agent: a transesophageal Doppler echocardiographic study. , 1996, Journal of the American College of Cardiology.

[11]  E. Botvinick,et al.  Adenosine-induced coronary vasodilation during transesophageal Doppler echocardiography. Rapid and safe measurement of coronary flow reserve ratio can predict significant left anterior descending coronary stenosis. , 1995, Circulation.

[12]  J. Ross,et al.  Transthoracic two-dimensional high frequency (7.5 MHz) ultrasonic visualization of the distal left anterior descending coronary artery. , 1990, Journal of the American College of Cardiology.

[13]  M. Winniford,et al.  Comparison of coronary vasodilation with intravenous dipyridamole and adenosine. , 1991, Journal of the American College of Cardiology.

[14]  M. Cheitlin,et al.  Coronary blood flow reserve in acute aortic regurgitation. , 1995, Journal of the American College of Cardiology.

[15]  R. Schlief,et al.  Improved Doppler signal intensity in coronary arteries after intravenous peripheral injection of a lung-crossing contrast agent (SHU 508A) , 1994, Journal of the American College of Cardiology.

[16]  T. Okada,et al.  Measurement of coronary flow reserve in children by transthoracic Doppler echocardiography. , 1997, The American journal of cardiology.

[17]  S. Iliceto,et al.  Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation. , 1991, Circulation.

[18]  T. Akasaka,et al.  Phasic coronary flow characteristics in patients with constrictive pericarditis: comparison with restrictive cardiomyopathy. , 1997, Circulation.