Scintillation response of Xe gas studied by gamma-ray absorption and Compton electrons

In this study we report on the scintillation response of Xe gas under irradiation of gamma-rays in the energy range between 50 keV and 1.5 MeV. Xe gas was pressurized to 50 bar and tested as a detector for gamma spectroscopy. The gas was confined in a titanium vessel of 200 mm length and 101 mm diameter with 2.5 mm thick walls. The vessel was sealed with two 3 inch diameter UV transparent windows. The inner surface of the vessel was covered with a reflecting wavelength shifter. Two photomultipliers coupled to both windows at the end of the vessel allowed for registration of 3700 photoelectrons/MeV, which resulted in 7.0% energy resolution registered for 662 keV γ-rays from a 137Cs source. The non-proportionality of the photoelectron yield and intrinsic resolution was studied with gamma photoabsorption peaks. Due to the thickness of the detector vessel, the response of the Xe gas as a scintillator in the low energy range was performed by means of a Compton Coincidence Technique and compared with the gamma absorption results. The shape of the non-proportionality characteristics of Xe gaseous scintillator was compared to the results obtained for NaI:Tl, LaBr3:Ce and LYSO:Ce. A correlation between non-proportionality and intrinsic resolution of Xe gaseous scintillator was pointed out.

[1]  F. Resnati Pressurised xenon as scintillator for gamma spectroscopy , 2013, 1309.2096.

[2]  M. Moszynski,et al.  Response of doped alkali iodides measured with gamma-ray absorption and Compton electrons , 2013 .

[3]  A. Curioni,et al.  Suitability of high-pressure xenon as scintillator for gamma ray spectroscopy , 2012, 1212.4050.

[4]  W. Skulski,et al.  The Large Underground Xenon (LUX) experiment , 2012, 1211.3788.

[5]  M. Moszynski,et al.  Electron response of some low-Z scintillators in wide energy range , 2012 .

[6]  M. Moszynski,et al.  Non-Proportionality of Electron Response and Energy Resolution of Compton Electrons in Scintillators , 2012, IEEE Transactions on Nuclear Science.

[7]  M. Moszynski,et al.  Energy resolution and nonlinearity of NaI(Tl), CaF2(Eu), and plastic scintillators measured with the wide-angle Compton-coincidence technique , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[8]  D. Nygren,et al.  ADDENDUM Addendum: Primary and secondary scintillation measurements in a Xenon Gas Proportional Scintillation Counter Addendum: Primary and secondary scintillation measurements in a Xenon Gas Proportional Scintillation Counter , 2010, 1009.2719.

[9]  D. Mcgregor,et al.  Design and performance of a Compton-coincidence system for measuring non-proportionality of new scintillators , 2010 .

[10]  T. Lux,et al.  Secondary scintillation yield in high-pressure xenon gas for neutrinoless double beta decay (0νββ) search , 2010 .

[11]  G. Bizarri,et al.  Progress in Studying Scintillator Proportionality: Phenomenological Model , 2009, IEEE Transactions on Nuclear Science.

[12]  G. Bizarri,et al.  Measurements of NaI(Tl) Electron Response: Comparison of Different Samples , 2009, IEEE Transactions on Nuclear Science.

[13]  L. Fernandes,et al.  GEM scintillation readout with avalanche photodiodes , 2007 .

[14]  A. Bolozdynya,et al.  Noble Gas Detectors , 2006 .

[15]  J. D. Valentine,et al.  Benchmarking the Compton coincidence technique for measuring electron response non-proportionality in inorganic scintillators , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[16]  P. Dorenbos,et al.  Non-proportionality in the scintillation response and the energy resolution obtainable with scintill , 1995 .