Spectral resolution in pixel detectors with single photon processing

Pixel detectors based on photon counting or single photon processing readout are becoming popular for spectral X-ray imaging. The detector is based on deep submicron electronics with functions to determine the energy of each individual photon in every pixel. The system is virtually noiseless when it comes to the number of the detected photons. However noise and variations in system parameters affect the determination of the photon energy. Several factors affect the energy resolution in the system. In the readout electronics the most important factors are the threshold dispersion, the gain variation and the electronic noise. In the sensor contributions come from charge sharing, variations in the charge collection efficiency, leakage current and the statistical nature of the charge generation, as described by the Fano factor. The MEDIPIX technology offers a powerful tool for investigating these effects since energy spectra can be captured in each pixel. In addition the TIMEPIX chip, when operated in Time over Threshold mode, offers an opportunity to analyze individual photon interactions, thus addressing charge sharing and fluorescence. Effects of charge sharing and the properties of charge summing can be investigated using MEDIPIX3RX. Experiments are performed using both Si and CdTe detectors. In this paper we discuss the various contributions to the spectral noise and how they affect detector response. The statements are supported with experimental data from MEDIPIX-type detectors.

[1]  Michael Campbell,et al.  Characterisation of an epitaxial GaAs/Medipix2 detector using fluorescence photons , 2008 .

[2]  Alan Owens,et al.  On the experimental determination of the Fano factor in Si at soft X-ray wavelengths , 2002 .

[3]  E. Papp-Szabó,et al.  A new approach to the determination of the Fano factor for semiconductor detectors , 2005 .

[4]  Depth of interaction and bias voltage depenence of the spectral response in a pixellated CdTe detector operating in time-over-threshold mode subjected to monochromatic X-rays , 2012 .

[5]  R. Dinapoli,et al.  Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting mode , 2001 .

[6]  G. Stewart,et al.  Imaging and spectroscopic performance studies of pixellated CdTe Timepix detector , 2012 .

[7]  C. Kenney,et al.  3D — A proposed new architecture for solid-state radiation detectors , 1997 .

[8]  Daniel Turecek,et al.  Pixelman: a multi-platform data acquisition and processing software package for Medipix2, Timepix and Medipix3 detectors , 2011 .

[9]  Walter Snoeys,et al.  Performance of a 4096-pixel photon counting chip , 1998, Optics & Photonics.

[10]  Michael Campbell,et al.  Study of the charge sharing in a silicon pixel detector by means of α-particles interacting with a Medipix2 device , 2008 .

[11]  Tadayui Takahashi,et al.  Recent progress in CdTe and CdZnTe detectors , 2001, astro-ph/0107398.

[12]  Michael Campbell,et al.  The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging , 2013 .

[13]  Rafael Ballabriga,et al.  Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements , 2007 .

[14]  B. G. Lowe,et al.  A measurement of the electron–hole pair creation energy and the Fano factor in silicon for 5.9 keV X-rays and their temperature dependence in the range 80–270 K , 2007 .

[15]  P. Delpierre,et al.  XPAD: A photons counting pixel detector for material sciences and small-animal imaging , 2007 .

[16]  Juha Kalliopuska,et al.  Characterization of edgeless pixel detectors coupled to Medipix2 readout chip , 2011 .

[17]  R. James,et al.  Internal Electric Field Investigations of a Cadmium Zinc Telluride Detector Using Synchrotron X-ray Mapping and Pockels Effect Measurements , 2009 .

[18]  M. N. Mazziotta,et al.  Electron–hole pair creation energy and Fano factor temperature dependence in silicon , 2008 .

[19]  Roberto Dinapoli,et al.  PILATUS: A single photon counting pixel detector for X-ray applications , 2009 .

[20]  Goro Sato,et al.  Development of Low-Noise Front-End ASIC for Hybrid CdTe Pixel Detectors , 2011, IEEE Transactions on Nuclear Science.

[21]  Vaclav Kraus,et al.  FITPix ? fast interface for Timepix pixel detectors , 2011 .

[22]  K. T. Kohman,et al.  Performance-limiting Defects in CdZnTe Detectors , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[23]  Marcos Bavdaz,et al.  Hard X-ray test and evaluation of a prototype 32 32 pixel gallium-arsenide array , 2002 .

[24]  Roberto Dinapoli,et al.  Performance of a single photon counting microstrip detector for strip pitches down to 10 μm , 2008 .

[25]  I. J. Nakonechnyj,et al.  Extended Defects in CdZnTe Radiation Detectors , 2009, IEEE Transactions on Nuclear Science.

[26]  C. Svensson,et al.  Evaluation of a Second-Generation Ultra-Fast Energy-Resolved ASIC for Photon-Counting Spectral CT , 2013, IEEE Transactions on Nuclear Science.

[27]  Karl Jakobs,et al.  Medipix2: Processing and measurements of GaAs pixel detectors , 2007 .

[28]  C. Fröjdh,et al.  Spectral X-ray imaging with single photon processing detectors , 2013 .

[29]  Ezio Caroli,et al.  Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications , 2009, Sensors.

[30]  B. Schmitt,et al.  EIGER: Next generation single photon counting detector for X-ray applications , 2011 .

[31]  X. L. Cudie Design and characterization of 64K pixels chips working in single photon processing mode , 2007 .

[32]  U. Fano Ionization Yield of Radiations. II. The Fluctuations of the Number of Ions , 1947 .

[33]  X. Llopart,et al.  First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).