Review of wear mechanisms in hip implants: Paper I – General

Abstract A review of wear mechanisms has been carried out in this paper for the hip prostheses. The primary causes of premature failure in hip prostheses are due to wearing of the implants. Multiple variables interact and increase the resultant wear rates. A summary of clinical in vivo and bulk material wear rate data from published literature has been presented for polyethylene-on-metal, metal-on-metal, and ceramic implants. This article addresses the engineering aspects concerning the advantages and disadvantages of each type of articulation. Wear mechanisms are discussed as a function of contact stresses, lubricants and clearance, surface hardness and roughness, type of articulation due to motion, number of cycles, solution particle count and distribution, oxidation of materials, and surface abrasions of both metal and polyethylene particulates. These issues are reviewed in this review.

[1]  H. M. Schüller,et al.  Ten-year socket wear in 66 hip arthroplasties. Ceramic versus metal heads. , 1990, Acta orthopaedica Scandinavica.

[2]  D Dowson,et al.  Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. , 1996, The Journal of bone and joint surgery. British volume.

[3]  P. Devane,et al.  Assessment of polyethylene wear in total hip replacement. , 1999, Clinical orthopaedics and related research.

[4]  I. Clarke,et al.  Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene. , 1999, Acta orthopaedica Scandinavica.

[5]  Julia C. Shelton,et al.  A hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions , 2001 .

[6]  K. Takaoka,et al.  Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study. , 1995, The Journal of bone and joint surgery. British volume.

[7]  F. Chan,et al.  Comparison of Alloys and Designs in a Hip Simulator Study of Metal on Metal Implants , 1996, Clinical orthopaedics and related research.

[8]  B. Morrey,et al.  Effect of femoral head size on wear of the polyethylene acetabular component. , 1990, The Journal of bone and joint surgery. American volume.

[9]  C. Ranawat,et al.  Comparison of polyethylene wear in machined versus molded polyethylene. , 1995, Clinical orthopaedics and related research.

[10]  J. Davidson,et al.  Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear. , 1993, Clinical orthopaedics and related research.

[11]  S. Woolson,et al.  Wear of the polyethylene of Harris-Galante acetabular components inserted without cement. , 1995, The Journal of bone and joint surgery. American volume.

[12]  R C Johnston,et al.  Charnley Total Hip Arthroplasty with Use of Improved Techniques of Cementing. The Results after a Minimum of Fifteen Years of Follow-up* , 1997, The Journal of bone and joint surgery. American volume.

[13]  A Sarmiento,et al.  The origin of submicron polyethylene wear debris in total hip arthroplasty. , 1995, Clinical orthopaedics and related research.

[14]  Effect of Counterface Material on the Characteristics of Retrieved Uncemented Cobalt-Chromium and Titanium Alloy Total Hip Replacements , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[15]  T. Wright,et al.  Role of polyethylene oxidation and consolidation defects in cup performance. , 1998, Clinical orthopaedics and related research.

[16]  C. Engh,et al.  Wear of Polyethylene Cups in Total Hip Arthroplasty. A Study of Specimens Retrieved Post Mortem* , 1996, The Journal of bone and joint surgery. American volume.

[17]  A. Wang,et al.  Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[18]  H. Okumura Socket wear in total hip prosthesis with alumina ceramic head , 1989 .

[19]  D R Pedersen,et al.  Ceramic-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty: Seventeen to Twenty-one-Year Results , 2001, The Journal of bone and joint surgery. American volume.