Microcirculation volumetric flow assessment using high-resolution, contrast-assisted images

To improve the resolution of contrast-assisted imaging systems, we previously developed a 25-MHz microbubbles-destruction/replenishment imaging system with a spatial resolution of 160 X 160 mum. The goal of the present study was to propose a new approach for functionally evaluating the microvascular volumetric blood flow based on this high-frequency, ultrasound imaging system. The approach includes locating the perfusion area and estimating the blood flow velocity therein. Because the correlation changes between before and after microbubble destruction in two adjacent images, a correlated-based approach was introduced to detect the blood perfusion area. We also have derived a new sigmoid-based model for characterizing the microbubbles replenishment process. Two parameters derived from the sigmoid-based model - the rate constant and inflection time - were adopted to evaluate the blood flow velocity. This model was validated using both simulations and in vitro experiments for mean flow velocities ranging from 1 to 10 mm/s, which showed that the model was in good agreement with simulated and measured microbubble-replenishment time-intensity curves. The results indicate that the actual flow velocity is highly correlated with the estimates of the rate constant and the reciprocal of the inflection time. B-mode imaging experiments for mean flow velocities ranging from 0.4 to 2.1 mm/s were used to assess the volumetric flow in the microcirculation. The results indicated the high correlation between the actual volumetric flow rate and the product of the estimated perfusion area and rate constant, and the reciprocal of the inflection time. We also found that the boundary of the microbubble destruction volume significantly affected estimations of the flow velocity. The perfusion area can be located, and the corresponding flow velocity can be estimated simultaneously in a one-stage, microbubble-destruction/replenishment process, which makes the assessment of the volumetric blood flow in the microcirculation feasible using a real-time, high-frequency ultrasound system.

[1]  A. DeMaria,et al.  Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves. , 2001, Journal of the American College of Cardiology.

[2]  D. A. Christopher,et al.  40-MHZ echocardiography scanner for cardiovascular assessment of mouse embryos. , 1998, Ultrasound in medicine & biology.

[3]  J. Folkman,et al.  Tumor angiogenesis and metastasis--correlation in invasive breast carcinoma. , 1991, The New England journal of medicine.

[4]  A. Guyton,et al.  Human Physiology and Mechanisms of Disease , 1982 .

[5]  Xiaoping Zhou,et al.  A new formalism for the quantification of tissue perfusion by the destruction-replenishment method in contrast ultrasound imaging , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  H. Becher,et al.  Feasibility of the flash-replenishment concept in renal tissue: which parameters affect the assessment of the contrast replenishment? , 2001, Ultrasound in medicine & biology.

[7]  K.W. Ferrara,et al.  A new high resolution color flow system using an eigendecomposition-based adaptive filter for clutter rejection , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  M. Kohno,et al.  Myocardial blood flow measurements in rats with simple pulsing contrast echocardiography. , 2002, Ultrasound in medicine & biology.

[9]  Fabian Kiessling,et al.  A multivessel model describing replenishment kinetics of ultrasound contrast agent for quantification of tissue perfusion. , 2003, Ultrasound in medicine & biology.

[10]  N. de Jong,et al.  A new ultrasound contrast imaging approach based on the combination of multiple imaging pulses and a separate release burst , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Chih-Kuang Yeh,et al.  The Correlation-Based Algorithm to Perfusion Assessment in Ultrasound Image , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[12]  A R Jayaweera,et al.  Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. , 1998, Circulation.

[13]  Paul A. Dayton,et al.  Optical observation of contrast agent destruction , 2000 .

[14]  F. Stuart Foster,et al.  High-frequency color flow imaging of the microcirculation , 2000 .

[15]  G. Seidel,et al.  Harmonic imaging--a new method for the sonographic assessment of cerebral perfusion. , 2001, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[16]  D. May,et al.  Nondestructive subharmonic imaging , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  J W Hunt,et al.  A method for computer simulation of ultrasound Doppler color flow images--I. Theory and numerical method. , 1992, Ultrasound in medicine & biology.

[18]  G. Seidel,et al.  Evaluation of blood flow in the cerebral microcirculation: analysis of the refill kinetics during ultrasound contrast agent infusion. , 2001, Ultrasound in medicine & biology.

[19]  S. Kaul,et al.  Quantification of Cerebral Perfusion With “Real-Time” Contrast-Enhanced Ultrasound , 2001, Circulation.

[20]  L From,et al.  A 40-100 MHz B-scan ultrasound backscatter microscope for skin imaging. , 1995, Ultrasound in medicine & biology.

[21]  Chih-Kuang Yeh,et al.  High-resolution functional vascular assessment with ultrasound , 2004, IEEE Transactions on Medical Imaging.

[22]  R. Folberg,et al.  The morphologic characteristics of tumor blood vessels as a marker of tumor progression in primary human uveal melanoma: a matched case-control study. , 1992, Human pathology.

[23]  C. Yeh,et al.  Destruction Threshold Parameters Estimation for Ultrasonic Contrast Agents , 2005 .

[24]  R. Karshafian,et al.  Quantification of flow using ultrasound and microbubbles: a disruption replenishment model based on physical principles. , 2009, Ultrasound in medicine & biology.

[25]  P. Dayton,et al.  Mechanisms of contrast agent destruction , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  F. Lizzi,et al.  High-resolution ultrasonic imaging and characterization of the ciliary body. , 2001, Investigative ophthalmology & visual science.

[27]  R. J. Fornaris,et al.  A swept-scanning mode for estimation of blood velocity in the microvasculature , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  Olivier Lucidarme,et al.  Blood flow quantification with contrast-enhanced US: "entrance in the section" phenomenon--phantom and rabbit study. , 2003, Radiology.

[29]  P. Dayton,et al.  Threshold of fragmentation for ultrasonic contrast agents. , 2001, Journal of biomedical optics.

[30]  Foster Fs,et al.  ULTRASOUND BIOMICROSCOPY: High-Frequency Ultrasound Imaging of the Eye at Microscopic Resolution , 1998 .

[31]  S. Kaul,et al.  Quantification of renal blood flow with contrast-enhanced ultrasound. , 2001, Journal of the American College of Cardiology.

[32]  A. Tarkkanen,et al.  Microvascular density in predicting survival of patients with choroidal and ciliary body melanoma. , 1999, Investigative ophthalmology & visual science.