Adaptive Neuro-Fuzzy and Simple Adaptive Control Methods for Alleviating the Seismic Responses of Coupled Buildings with Semi-active Devices: Comparative Study

This paper describes two adaptive control methods for mitigating the seismic responses of two connected buildings with MR dampers at different levels. First method developed in this study is the adaptive neuro-fuzzy controller which consists of a fuzzy logic controller provided with learning algorithm based on adaptive neural networks. The learning algorithm is implemented to modify the parameters of the fuzzy logic controller such that its outputs track the behavior of predetermined training data. Second method is the simple adaptive controller which falls into the category of model-following adaptive strategies. In this method, a plant is commanded to follow a well-designed reference-model with desirable trajectories through a closed loop action. The coupled system consists of two adjacent buildings having different heights in order to separate the model shapes of the individual buildings. Different types of feedbacks such as displacement, velocity, and acceleration are employed to identify their impacts on the performance of the developed adaptive controllers. Numerical analyses are carried out for the complex system assuming no change in the nominal design parameters and then for the system where a change in these parameters is introduced. The results reveal that using the adaptive controllers developed in this study to regulate the MR dampers connecting the two adjacent buildings can successfully alleviate the seismic responses under various types and intensities of earthquakes.

[1]  Itzhak Barkana,et al.  The beauty of simple adaptive control and new developments in nonlinear systems stability analysis , 2014 .

[2]  S. Lau,et al.  Steady-state oscillation of hysteretic differential model. I: Response analysis , 1994 .

[3]  Stefan Hurlebaus,et al.  Active and Semi‐active Adaptive Control for Undamaged and Damaged Building Structures Under Seismic Load , 2012, Comput. Aided Civ. Infrastructure Eng..

[4]  Luciana R. Barroso,et al.  Semi-active adaptive control for enhancing the seismic performance of nonlinear coupled buildings with smooth hysteretic behavior , 2019, Engineering Structures.

[5]  Luciana R. Barroso,et al.  Utilizing the Adaptive Control in Mitigating the Seismic Response of Adjacent Buildings Connected with MR Dampers , 2018, 2018 Annual American Control Conference (ACC).

[6]  Huaxia Deng,et al.  Magnetorheological Damper Working in Squeeze Mode , 2014 .

[7]  A. Guez,et al.  Simple adaptive control for a class of non-linear systems with application to robotics , 1990 .

[8]  Shirley J. Dyke,et al.  PHENOMENOLOGICAL MODEL FOR MAGNETORHEOLOGICAL DAMPERS , 1997 .

[9]  Paul N. Roschke,et al.  Neuro-fuzzy control of structures using acceleration feedback , 2001 .

[10]  Paul N. Roschke,et al.  Neuro-fuzzy control of structures using magnetorheological dampers , 2001, Proceedings of the 2001 American Control Conference. (Cat. No.01CH37148).

[11]  Kenneth K. Walsh,et al.  Closed‐form equations for coupling linear structures using stiffness and damping elements , 2013 .

[12]  Kazuto Seto,et al.  Active Vibration Control of Structures Arranged in Parallel , 1994 .

[13]  Luciana R. Barroso,et al.  Simple Adaptive Control Strategy Applied to Reduce Response of Bridge Structure Subjected to Changes in Plant , 2018, 2018 Annual American Control Conference (ACC).

[14]  Fereidoun Amini,et al.  Impacts of soil-structure interaction on the structural control of nonlinear systems using adaptive control approach , 2018 .

[15]  Steve Ulrich,et al.  Simple Adaptive Control for Spacecraft Proximity Operations , 2014 .

[16]  Petros A. Ioannou,et al.  Adaptive Systems with Reduced Models , 1983 .

[17]  Erik A. Johnson,et al.  "SMART" BASE ISOLATION SYSTEMS , 2000 .

[18]  Shirley J. Dyke,et al.  An experimental study of MR dampers for seismic protection , 1998 .

[19]  Fereidoun Amini,et al.  Control of a building complex with Magneto-Rheological Dampers and Tuned Mass Damper , 2010 .

[20]  EVALUATING THE EFFECTIVENESS OF STRUCTURAL CONTROL WITHIN THE CONTEXT OF PERFORMANCE-BASED ENGINEERING , 2000 .

[21]  Roland S. Burns,et al.  Advanced control engineering , 2001 .

[22]  Y. Matsumoto,et al.  Active vibration control of multiple buildings connected with active control bridges in response to large earthquakes , 1999, Proceedings of the 1999 American Control Conference (Cat. No. 99CH36251).

[23]  Fumio Doi,et al.  Bending and Torsional Vibration Control for Flexible Structures arranged in Parallel. , 1998 .

[24]  E. Mizutani,et al.  Neuro-Fuzzy and Soft Computing-A Computational Approach to Learning and Machine Intelligence [Book Review] , 1997, IEEE Transactions on Automatic Control.

[25]  S. M. Dumne,et al.  Seismic response analysis of adjacent buildings connected with MR dampers , 2010 .

[26]  Chih-Chen Chang,et al.  Shear-Mode Rotary Magnetorheological Damper for Small-Scale Structural Control Experiments , 2004 .

[27]  Hyung-Jo Jung,et al.  Semi‐active fuzzy control for seismic response reduction using magnetorheological dampers , 2004 .

[28]  Abdelhafid Ounis,et al.  Retrofitting of a weaker building by coupling it to an adjacent stronger building using MR dampers , 2017 .

[29]  Luciana R. Barroso,et al.  Simple adaptive control method for mitigating the seismic responses of coupled adjacent buildings considering parameter variations , 2019, Engineering Structures.

[30]  Mehmet E. Uz,et al.  Optimal design of semi active control for adjacent buildings connected by mr damper based on integrated fuzzy logic and multi-objective genetic algorithm , 2014 .

[31]  Jyh-Shing Roger Jang,et al.  ANFIS: adaptive-network-based fuzzy inference system , 1993, IEEE Trans. Syst. Man Cybern..

[32]  Bruce D. Westermo,et al.  The dynamics of interstructural connection to prevent pounding , 1989 .

[33]  B. F. Spencer Reliability of Randomly Excited Hysteretic Structures , 1986 .

[34]  Michael D. Symans,et al.  Fuzzy logic control of bridge structures using intelligent semi‐active seismic isolation systems , 1999 .