Continuous Sorting of Cells Based on Differential P Selectin Glycoprotein Ligand Expression Using Molecular Adhesion.

Cell surface molecular adhesions govern many important physiological processes and are used to identify cells for analysis and purifications. But most effective cell adhesion separation technologies use labels or long-term attachments in their application. While label-free separation microsystems typically separate cells by size, stiffness, and shape, they often do not provide sufficient specificity to cell type that can be obtained from molecular expression. We demonstrate a label-free microfluidic approach capable of high throughput separation of cells based upon surface molecule adhesion. Cells are flowed through a microchannel designed with angled ridges at the top of the channel and coated with adhesive ligands specific to target cell receptors. The ridges slightly compress passing cells such that adhesive contact can be made with sufficient surface area without unduly affecting cell trajectories because of cell stiffness. Thus, sorting is sensitive to cell adhesion but not to stiffness or cell size. The enforced interactions between the cells and the ridges ensure that a high flow rate can be used without lift forces quenching adhesion. As a proof of principle of the method, we separate both Jurkat and HL60 cell lines based on their differential expression of PSGL-1 ligand by using a ridged channel coated with P selectin. We demonstrate 26-fold and 3.8-fold enrichment of PSGL-1 positive and 4.4-fold and 3.2-fold enrichment of PSGL-1 negative Jurkat and HL60 cells, respectively. Increasing the number of outlets to five allows for greater resolution in PSGL-1 selection resulting in fractionation of a single cell type into subpopulations of cells with high, moderate, and low PSGL-1 expression. The cells can flow at a rate of up to 0.2 m/s, which corresponds to 0.045 million cells per minute at the designed geometry, which is over 2 orders of magnitude higher than previous adhesive-based sorting approaches. Because of the short interaction time of the cells with the adhesive surfaces, the sorting method does not further activate the cells due to molecular binding. Such an approach may find use in label-free selection of cells for a highly expressed molecular phenotype.

[1]  Andreas Radbruch,et al.  High gradient magnetic cell separation with MACS. , 1990, Cytometry.

[2]  Sungyoung Choi,et al.  Tuneable hydrophoretic separation using elastic deformation of poly(dimethylsiloxane). , 2009, Lab on a chip.

[3]  A. Weyrich,et al.  Engagement of P-selectin Glycoprotein Ligand-1 Enhances Tyrosine Phosphorylation and Activates Mitogen-activated Protein Kinases in Human Neutrophils* , 1997, The Journal of Biological Chemistry.

[4]  Massimo Cristofanilli,et al.  Considerations in the development of circulating tumor cell technology for clinical use , 2012, Journal of Translational Medicine.

[5]  M. Shimojima,et al.  Human P-selectin glycoprotein ligand-1 is a functional receptor for enterovirus 71 , 2009, Nature Medicine.

[6]  T. Naoe,et al.  Target Antigen Density Governs the Efficacy of Anti–CD20-CD28-CD3 ζ Chimeric Antigen Receptor–Modified Effector CD8+ T Cells , 2015, The Journal of Immunology.

[7]  Wei Liu,et al.  Magneto-controllable capture and release of cancer cells by using a micropillar device decorated with graphite oxide-coated magnetic nanoparticles. , 2013, Small.

[8]  Ashutosh Kumar Singh,et al.  Adhesive Signature-based, Label-free Isolation of Human Pluripotent Stem Cells , 2012, Nature Methods.

[9]  E. Berg,et al.  Neutrophil Mac-1 and MEL-14 adhesion proteins inversely regulated by chemotactic factors. , 1989, Science.

[10]  Todd Sulchek,et al.  Stiffness Dependent Separation of Cells in a Microfluidic Device , 2012, PloS one.

[11]  Jeffrey M Karp,et al.  Mesenchymal stem cell homing: the devil is in the details. , 2009, Cell stem cell.

[12]  N. Tolan,et al.  Probing dynamic cell-substrate interactions using photochemically generated surface-immobilized gradients: application to selectin-mediated leukocyte rolling. , 2011, Integrative biology : quantitative biosciences from nano to macro.

[13]  Mehmet Toner,et al.  A microfluidic device for practical label-free CD4(+) T cell counting of HIV-infected subjects. , 2007, Lab on a chip.

[14]  Jianping Fu,et al.  Microfluidic blood cell sorting: now and beyond. , 2014, Small.

[15]  Chulhee Choi,et al.  Hydrophoretic high-throughput selection of platelets in physiological shear-stress range. , 2011, Lab on a chip.

[16]  David W. Inglis,et al.  Efficient microfluidic particle separation arrays , 2009 .

[17]  T. Crowley,et al.  Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications. , 2005, Lab on a chip.

[18]  K. Gustafsson,et al.  Avoidance of On-Target Off-Tumor Activation Using a Co-stimulation-Only Chimeric Antigen Receptor. , 2017, Molecular therapy : the journal of the American Society of Gene Therapy.

[19]  M. Shah,et al.  The relevance of drug sequence in combination chemotherapy. , 2000, Drug resistance updates : reviews and commentaries in antimicrobial and anticancer chemotherapy.

[20]  Henk J. Busscher,et al.  Preparation and characterization of chemical gradient surfaces and their application for the study of cellular interaction phenomena , 1997 .

[21]  H. Ji,et al.  Silicon-based microfilters for whole blood cell separation , 2008, Biomedical microdevices.

[22]  P. Dodd,et al.  Nucleic acid aptamers as novel class of therapeutics to mitigate Alzheimer's disease pathology. , 2013, Current Alzheimer research.

[23]  Hannes Stockinger,et al.  CD molecules 2006--human cell differentiation molecules. , 2007, Journal of immunological methods.

[24]  Jeffrey M Karp,et al.  Cell sorting by deterministic cell rolling. , 2012, Lab on a chip.

[25]  Sangeeta N. Bhatia,et al.  A combinatorial extracellular matrix platform identifies cell-extracellular matrix interactions that correlate with metastasis , 2012, Nature Communications.

[26]  L. Bradley,et al.  PSGL-1: A New Player in the Immune Checkpoint Landscape. , 2017, Trends in immunology.

[27]  James C Baygents,et al.  Detachment of captured cancer cells under flow acceleration in a bio-functionalized microchannel. , 2009, Lab on a chip.

[28]  C. Lim,et al.  AFM indentation study of breast cancer cells. , 2008, Biochemical and biophysical research communications.

[29]  Rohit Karnik,et al.  Affinity flow fractionation of cells via transient interactions with asymmetric molecular patterns , 2013, Scientific Reports.

[30]  M. Bosenberg,et al.  PSGL-1 Is an Immune Checkpoint Regulator that Promotes T Cell Exhaustion. , 2016, Immunity.

[31]  E. Kohn,et al.  Adhesion molecule protein signature in ovarian cancer effusions is prognostic of patient outcome , 2012, Cancer.

[32]  Todd Sulchek,et al.  Microfluidic cellular enrichment and separation through differences in viscoelastic deformation. , 2015, Lab on a chip.

[33]  D. Hammer,et al.  Cell separation mediated by differential rolling adhesion. , 2001, Biotechnology and bioengineering.

[34]  A. Lenhoff,et al.  Size does matter: electrostatically determined surface coverage trends in protein and colloid adsorption , 2000 .

[35]  R. McEver Selectins: initiators of leucocyte adhesion and signalling at the vascular wall. , 2015, Cardiovascular research.

[36]  Sungyoung Choi,et al.  Continuous hydrophoretic separation and sizing of microparticles using slanted obstacles in a microchannel. , 2007, Lab on a chip.

[37]  Mohamed El Banani,et al.  Three-dimensional particle tracking in microfluidic channel flow using in and out of focus diffraction , 2015 .