An optical 3D digitizer for frameless stereotactic surgery

This frameless system for defining the precise spatial coordinates of a site of surgical interest has many advantages over conventional frame based systems and provides accuracy comparable to commonly used units. The system uses computer hardware and software to reconstruct 2D digital images into a 3D volumetric image display. The 3D images, when combined with a spatially digitizing sensor to define a location in space, can be directly registered to anatomical structures or markers in the surgical field. The display can then be used to track the sensor position and, therefore, the surgical position, thus eliminating the guesswork of intuitively transferring radiographic information to the operative field. This system, the ISG Viewing Wand, has proved to be objective and accurate at integrating imaging data with the structures in the operative field, with a clinical accuracy of approximately 3 millimeters.

[1]  J. Strohbehn,et al.  A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope. , 1986, Journal of neurosurgery.

[2]  R. Maciunas,et al.  The accuracies of four stereotactic frame systems: an independent assessment. , 1991, Biomedical instrumentation & technology.

[3]  S J Zinreich,et al.  In vivo accuracy testing and clinical experience with the ISG Viewing Wand. , 1996, Neurosurgery.

[4]  M Dujovny,et al.  Multiplanar CT-guided stereotaxis and 125I interstitial radiotherapy. Image-guided tumor volume assessment, planning, dosimetric calculations, stereotactic biopsy and implantation of removable catheters. , 1987, Applied neurophysiology.

[5]  Robert L. Galloway,et al.  A three-dimensional locating pointer for stereotactic neurosurgery , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[6]  M. Kendall,et al.  Kendall's advanced theory of statistics , 1995 .

[7]  M W Vannier,et al.  Validation study of skull three-dimensional computerized tomography measurements. , 1990, American journal of physical anthropology.

[8]  J K Vries,et al.  Stereotactic implantation of deep brain electrodes using computed tomography. , 1983, Neurosurgery.

[9]  B. Crain,et al.  Fine needle aspiration biopsy of deep cerebrum. A comparison of normal and neoplastic morphology. , 1982, Acta cytologica.

[10]  H. W. Korin,et al.  Adaptive technique for three-dimensional MR imaging of moving structures. , 1990, Radiology.

[11]  D. Long,et al.  Frameless stereotaxic integration of CT imaging data: accuracy and initial applications. , 1993, Radiology.