Methods: a comparative analysis of radiography, microcomputed tomography, and histology for bone tissue engineering.

This study focused on the assessment of radiography, microcomputed tomography, and histology for the evaluation of bone formation in a 15.0-mm defect in the rabbit radius after the implantation of a tissue-engineered construct. Radiography was found to be useful as a noninvasive method for obtaining images of calcified tissue throughout the time course of the experiment. With this method, however, image quality was low, making it difficult to obtain precise information about the location and quantity of the bone formed. Microcomputed tomography was used to create three-dimensional reconstructions of the bone (25-microm resolution). These reconstructions allowed for greater spatial resolution than the radiography, but did not allow for imaging of the implanted scaffold material or the surrounding, nonmineralized tissue. To visualize all materials within the defect area at the cellular level, histology was used. Histological analysis, however, is a destructive technique that did not allow for any further analysis of the samples. Each technique examined here has its own advantages and limitations, but each yields unique information regarding bone regeneration. It is only through the use of all three techniques that complete characterization of the bone growth and tissue/construct responses after implantation in vivo.

[1]  Antonios G Mikos,et al.  In vitro degradation of porous poly(propylene fumarate)/poly(DL-lactic-co-glycolic acid) composite scaffolds. , 2005, Biomaterials.

[2]  J. Jansen,et al.  Effect of varied release kinetics of the osteogenic thrombin peptide TP508 from biodegradable, polymeric scaffolds on bone formation in vivo. , 2005, Journal of biomedical materials research. Part A.

[3]  Antonios G. Mikos,et al.  Flow Perfusion Enhances the Calcified Matrix Deposition of Marrow Stromal Cells in Biodegradable Nonwoven Fiber Mesh Scaffolds , 2005, Annals of Biomedical Engineering.

[4]  D Chappard,et al.  Synchrotron X-ray microtomography (on a micron scale) provides three-dimensional imaging representation of bone ingrowth in calcium phosphate biomaterials. , 2003, Biomaterials.

[5]  A. Mikos,et al.  Controlled release of an osteogenic peptide from injectable biodegradable polymeric composites. , 2002, Journal of controlled release : official journal of the Controlled Release Society.

[6]  Antonios G Mikos,et al.  Evaluation of the in vitro degradation of macroporous hydrogels using gravimetry, confined compression testing, and microcomputed tomography. , 2002, Biomacromolecules.

[7]  R. Brooks,et al.  The effects of particulate bone cements at the bone-implant interface. , 2001, The Journal of bone and joint surgery. British volume.

[8]  A. Mikos,et al.  Controlled release of transforming growth factor β1 from biodegradable polymer microparticles , 2000 .

[9]  G Van der Perre,et al.  Use of microfocus computerized tomography as a new technique for characterizing bone tissue around oral implants. , 2000, The Journal of oral implantology.

[10]  P Cloetens,et al.  A synchrotron radiation microtomography system for the analysis of trabecular bone samples. , 1999, Medical physics.

[11]  P. Rüegsegger,et al.  Direct Three‐Dimensional Morphometric Analysis of Human Cancellous Bone: Microstructural Data from Spine, Femur, Iliac Crest, and Calcaneus , 1999, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[12]  D. Murray,et al.  Radio-opaque Agents In Bone Cement Increase Bone Resorption , 1997 .

[13]  D. Murray,et al.  Radio-opaque agents in bone cement increase bone resorption. , 1997, The Journal of bone and joint surgery. British volume.

[14]  F. Wong,et al.  X-ray microtomography of bones and teeth. , 1996, Physiological measurement.

[15]  J. Zerwekh,et al.  Porous ceramics as bone graft substitutes in long bone defects: A biomechanical, histological, and radiographic analysis , 1996, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[16]  J. Jansen,et al.  Histological Assessment of Sintered Metal- Fibre-Web Materials , 1994, Journal of biomaterials applications.

[17]  P. Ducheyne,et al.  Comparison of the inflammatory response to particulate polymethylmethacrylate debris with and without barium sulfate , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[18]  D. Simmons,et al.  The healing of grafts combining freeze-dried and demineralized allogeneic bone in rabbits. , 1994, Clinical orthopaedics and related research.

[19]  C. Klein,et al.  A simple method for preparing thin (10 microM) histological sections of undecalcified plastic embedded bone with implants. , 1988, Stain technology.

[20]  J. Lane,et al.  Current approaches to experimental bone grafting. , 1987, The Orthopedic clinics of North America.

[21]  K. Heiple,et al.  The effect of histocompatibility matching on canine frozen bone allografts. , 1983, The Journal of bone and joint surgery. American volume.