Digital Angiography Using a Matched Filter

Both digital subtraction and recursive filtering schemes have been employed successfully for intravenous and intraarterial arteriography. Either processing method results in an image(s), S, which is a linear combination of discrete images Ij acquired during the flow of iodinated contrast material, i.e., S = 1; ¿Nj=0kjlj, j = 0 where kj are the weighting coefficients for the N+1 samples. It is shown that for a given set of images {Ij} there exists a set of weighting coefficients {kj} which maximizes the iodine signal to noise ratio and simultaneously removes stationary background anatomy. The kj are related to the contrast dilution curve measured over an artery of interest, kj = s[j]-s¿, where {s[j]} is the set of measured image variations due to the flow of contrast material, and s¿, is the mean value of the s[j]. This choice of kj defines a matched filter. Compared to subtraction angiography, matched filtering is 4-6 times more dose efficient.

[1]  R A Kruger,et al.  Digital video subtraction angiography for evaluation of peripheral vascular disease. , 1981, Radiology.

[2]  R A Kruger,et al.  Clinical applications of computerized fluoroscopy: the extracranial carotid arteries. , 1980, Radiology.

[3]  Thomas F. Meaney,et al.  Digital Subtraction Angiography Of The Human Cardiovascular System , 1980, Other Conferences.

[4]  S J Riederer,et al.  Computerized fluoroscopy in real time for noninvasive visualization of the cardiovascular system. Preliminary studies. , 1979, Radiology.

[5]  S J Riederer,et al.  Computerized fluoroscopy techniques for intravenous study of cardiac chamber dynamics. , 1979, Investigative radiology.

[6]  J. Sorenson,et al.  A method for the noninvasive evaluation of cardiovascular dynamics using a digital radiographic device. , 1981, Radiology.

[7]  S J Riederer,et al.  Three-beam K-edge imaging of iodine using differences between fluoroscopic video images: experimental results. , 1981, Medical physics.

[8]  R A Kruger A method for time domain filtering using computerized fluoroscopy. , 1981, Medical physics.

[9]  W R Brody,et al.  Hybrid subtraction for improved arteriography. , 1981, Radiology.

[10]  Robert A. Kruger,et al.  Time domain filtering using computerized fluoroscopy--intravenous angiography applications , 1981, Other Conferences.

[11]  S. Riederer,et al.  Digital K-edge subtraction radiography. , 1977, Radiology.

[12]  H Roehrig,et al.  Intravenous angiography using digital video subtraction: x-ray imaging system. , 1980, AJR. American journal of roentgenology.