Optimization of K-edge imaging with spectral CT.

PURPOSE Spectral∕multienergy CT has the potential to distinguish different materials by K-edge characteristics. K-edge imaging involves the two energy bins on both sides of a K-edge. The authors propose a K-edge imaging optimization model to determine these two energy bins. METHODS K-edge image contrast with spectral CT depends on the specifications of the two energy bins on both sides of a K-edge in the attenuation profile of a relatively high atomic number material. The wider the energy bin width is, the lower the noise level is, and the poorer the reconstructed image contrast is. Here the authors introduce the signal difference to noise ratio (SDNR) criterion to optimize the energy bin widths on both sides of the K-edge for the maximum SDNR. RESULTS The authors study K-edge imaging with spectral CT, analyze the effect of K-edge energy bins on the resultant image quality, and establish guidelines for the optimization of energy thresholds. In simulation, the authors demonstrate that our K-edge imaging optimization approach maximizes SDNR in reconstructed images. CONCLUSIONS This proposed approach can be readily generalized to deal with more general settings and determine the best energy bins for K-edge imaging.

[1]  Cyrill Burger,et al.  Cause and magnitude of the error induced by oral CT contrast agent in CT-based attenuation correction of PET emission studies. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  R. Dinapoli,et al.  Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting mode , 2001 .

[3]  Hans-Erik Nilsson,et al.  Spectroscopy applications for the Medipix photon counting X-ray system , 2004 .

[4]  R. F. Wagner,et al.  SNR and DQE analysis of broad spectrum X-ray imaging , 1985 .

[5]  P. Shikhaliev,et al.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application , 2011, Physics in medicine and biology.

[6]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[7]  P. Suetens,et al.  An iterative dual energy CT reconstruction method for a K-edge contrast material , 2011, Medical Imaging.

[8]  Anthony P. H. Butler,et al.  Image Reconstruction for Hybrid True-Color Micro-CT , 2012, IEEE Transactions on Biomedical Engineering.

[9]  M F Kijewski,et al.  The noise power spectrum of CT images. , 1987, Physics in medicine and biology.

[10]  A Fenster,et al.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems. , 1994, Medical physics.

[11]  S. Osher,et al.  Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM) , 2011, Inverse problems.

[12]  G Wang,et al.  Helical CT image noise--analytical results. , 1993, Medical physics.

[13]  E. Frey,et al.  MicroCT with energy-resolved photon-counting detectors , 2011, Physics in medicine and biology.

[14]  R. Steadman,et al.  Testing an Energy-Dispersive Counting-Mode Detector With Hard X-Rays From a Synchrotron Source , 2008, IEEE Transactions on Nuclear Science.

[15]  E. Roessl,et al.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors , 2007, Physics in medicine and biology.

[16]  A. Butler,et al.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE , 2010, European Radiology.

[17]  G. Anton,et al.  Quantitative Material Reconstruction in CT with Spectroscopic X-ray Pixel Detectors -- a Simulation Study , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[18]  Bruno De Man,et al.  An outlook on x-ray CT research and development. , 2008, Medical physics.

[19]  S. Riederer,et al.  Selective iodine imaging using K-edge energies in computerized x-ray tomography. , 1977, Medical physics.

[20]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[21]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[22]  Xin Jin,et al.  Preliminary experimental results from a MARS Micro-CT system. , 2012, Journal of X-ray science and technology.

[23]  Thilo Michel,et al.  Material resolving X-ray imaging using spectrum reconstruction with Medipix2 , 2008 .

[24]  Gisela Anton,et al.  Material reconstruction with spectroscopic pixel X-ray detectors , 2005 .

[25]  K. Bae,et al.  Gadolinium as a CT contrast agent: assessment in a porcine model. , 1999, Radiology.

[26]  Thilo Michel,et al.  Contrast agent recognition in small animal CT using the Medipix2 detector , 2009 .

[27]  Eiichi Sato,et al.  Demonstration of enhanced iodine K-edge imaging using an energy-dispersive X-ray computed tomography system with a 25 mm/s-scan linear cadmium telluride detector and a single comparator. , 2012, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[28]  Stefan Fiedler,et al.  Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: a feasibility study. , 2010, European journal of radiology.