Conical scan pattern for enhanced visualization of the human cornea using polarization-sensitive OCT

: Conventional imaging of the human cornea with optical coherence tomography (OCT) relies on telecentric scanning optics with sampling beams that are parallel to the optical axis of the eye. Because of the shape of the cornea, the beams have in some areas considerable inclination to the corneal surface which is accompanied by low signal intensities in these areas and thus an inhomogeneous appearance of corneal structures. In addition, alterations in the polarization state of the probing light depend on the angle between the imaging beam and the birefringent axis of the sample. Therefore, changes in the polarization state observed with polarization-sensitive (PS-) OCT originate mainly from the shape of the cornea. In order to minimize the effects of the corneal shape on intensity and polarization-sensitive based data, we developed a conical scanning optics design. This design provides imaging beams that are essentially orthogonal to the corneal surface. Thus, high signal intensity throughout the entire imaged volume is obtained and the influence of the corneal shape on polarization-sensitive data is greatly reduced. We demonstrate the benefit of the concept by comparing PS-OCT imaging results of the human cornea in healthy volunteers using both scanning schemes.

[1]  K. Meek,et al.  Corneal structure and transparency , 2015, Progress in Retinal and Eye Research.

[2]  J. Izatt,et al.  Complete 360° circumferential gonioscopic optical coherence tomography imaging of the iridocorneal angle. , 2015, Biomedical optics express.

[3]  Michael Pircher,et al.  Retinal nerve fiber bundle tracing and analysis in human eye by polarization sensitive OCT. , 2015, Biomedical optics express.

[4]  Masahiro Yamanari,et al.  Fiber-based polarization-sensitive OCT for birefringence imaging of the anterior eye segment. , 2015, Biomedical optics express.

[5]  Christoph K. Hitzenberger,et al.  Single input state polarization sensitive swept source optical coherence tomography based on an all single mode fiber interferometer , 2014, Biomedical optics express.

[6]  Yoshiaki Yasuno,et al.  Keratoconus diagnosis using anterior segment polarization-sensitive optical coherence tomography. , 2013, Investigative ophthalmology & visual science.

[7]  U. Schmidt-Erfurth,et al.  Polarization sensitive optical coherence tomography in the human eye , 2011, Progress in Retinal and Eye Research.

[8]  Yoshiaki Yasuno,et al.  Birefringence measurement of cornea and anterior segment by office-based polarization-sensitive optical coherence tomography , 2011, Biomedical optics express.

[9]  Terry Kim,et al.  Anatomy and physiology of the cornea , 2011, Journal of cataract and refractive surgery.

[10]  R. Huber,et al.  Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm Fourier domain mode-locked laser. , 2011, Optics express.

[11]  Valéria Lima Passos,et al.  Reproducibility of anterior chamber angle measurements with anterior segment optical coherence tomography. , 2011, Investigative ophthalmology & visual science.

[12]  Félix Fanjul-Vélez,et al.  Polarimetric analysis of the human cornea measured by polarization-sensitive optical coherence tomography. , 2010, Journal of biomedical optics.

[13]  S. Marcos,et al.  Optical distortion correction in optical coherence tomography for quantitative ocular anterior segment by three-dimensional imaging. , 2010, Optics express.

[14]  Shuichi Makita,et al.  Generalized Jones matrix optical coherence tomography: performance and local birefringence imaging. , 2010, Optics express.

[15]  C. Boote,et al.  The use of X-ray scattering techniques to quantify the orientation and distribution of collagen in the corneal stroma , 2009, Progress in Retinal and Eye Research.

[16]  U. Schmidt-Erfurth,et al.  Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography. , 2008, Optics express.

[17]  Marinko Sarunic,et al.  Detailed visualization of the anterior segment using fourier-domain optical coherence tomography. , 2008, Archives of ophthalmology.

[18]  Michael Pircher,et al.  Imaging of birefringent properties of keratoconus corneas by polarization-sensitive optical coherence tomography. , 2007, Investigative ophthalmology & visual science.

[19]  Michael Pircher,et al.  Corneal birefringence compensation for polarization sensitive optical coherence tomography of the human retina. , 2007, Journal of biomedical optics.

[20]  J. Mehta,et al.  Surgically induced astigmatism after phacoemulsification in eyes with mild to moderate corneal astigmatism: Temporal versus on‐axis clear corneal incisions , 2006, Journal of cataract and refractive surgery.

[21]  C. Hitzenberger,et al.  High speed spectral domain polarization sensitive optical coherence tomography of the human retina. , 2005, Optics express.

[22]  Harald Sattmann,et al.  Ultrahigh-resolution polarization-sensitive optical coherence tomography , 2005, SPIE BiOS.

[23]  Michael Pircher,et al.  Transversal phase resolved polarization sensitive optical coherence tomography , 2004, Physics in medicine and biology.

[24]  K. Meek,et al.  X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus. , 2004, Structure.

[25]  Michael Pircher,et al.  Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography. , 2004, Journal of biomedical optics.

[26]  R. Weinreb,et al.  Individualized compensation of anterior segment birefringence during scanning laser polarimetry. , 2002, Investigative ophthalmology & visual science.

[27]  F. Vargas-Martin,et al.  Measurements of the corneal birefringence with a liquid-crystal imaging polariscope. , 2002, Applied optics.

[28]  A. Fercher,et al.  Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography. , 2001, Optics express.

[29]  N. Fullwood,et al.  Corneal and scleral collagens--a microscopist's perspective. , 2001, Micron.

[30]  M J Everett,et al.  Mapping of Birefringence and Thermal Damage in Tissue by use of Polarization-Sensitive Optical Coherence Tomography. , 1998, Applied optics.

[31]  Thomas E. Milner,et al.  Two-dimensional birefringence imaging in biological tissue using polarization-sensitive optical coherence tomography , 1997, European Conference on Biomedical Optics.

[32]  A. Daxer,et al.  Collagen fibril orientation in the human corneal stroma and its implication in keratoconus. , 1997, Investigative ophthalmology & visual science.

[33]  T. Kohnen,et al.  Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes , 1995, Journal of cataract and refractive surgery.

[34]  J. Fujimoto,et al.  Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging , 1992 .

[35]  G. V. van Blokland,et al.  Corneal polarization in the living human eye explained with a biaxial model. , 1987, Journal of the Optical Society of America. A, Optics and image science.