An improved portable biosensing system based on enzymatic chemiluminescence and magnetic immunoassay for biological compound detection

Abstract In this paper, an improved portable biosensing system has been developed for biological compounds detection. The device is based on enzymatic chemiluminescence and magnetic immunoassay with a miniaturized flow injection module. The immunoassay procedure involved a sandwich format, in which the antigen in the sample was first captured by the immobilized primary antibody on the surface of the magnetic beads, and then recognized by the second antibody labeled with enzyme. 3-(2′-spiroadamantyl)-4-methoxy- 4-(3″-phosphoryloxy)-phenyl-1,2-dioxetane (AMPPD) as the substrate amplified the enzymatic signal for the biological compound measurement. The portable biosensing system was characterized in a series of experiments with cardiac troponin I (cTnI), a golden standard protein marker for diagnosis of myocardial infarction, as a biological substance measurement model. It provided a linear response range of cTnI from 0.1 to 50 ng mL −1 ( R  = 0.99). The coefficient of variation was 6.7% in the repeatability test ( n  = 6). The novel system has great potential applications in the rural and community hospitals and can be easily extended to a variety of protein compounds analysis.

[1]  Molecular sieves materials modified carbon paste electrodes for the determination of cardiac troponin I by anodic stripping voltammetry , 2005 .

[2]  Paul S. Francis,et al.  Pulsed flow chemistry: a new approach to solution handling for flow analysis coupled with chemiluminescence detection , 2000 .

[3]  Hugo A. Katus,et al.  Myocardial infarction redefined--a consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. , 2000, European heart journal.

[4]  P. Porela,et al.  Early markers of myocardial injury: cTnI is enough. , 2009, Clinica chimica acta; international journal of clinical chemistry.

[5]  Wei-Hua Huang,et al.  Integration of minisolenoids in microfluidic device for magnetic bead–based immunoassays , 2007 .

[6]  Jun‐Jie Zhu,et al.  Electrochemiluminescence of CdSe quantum dots for immunosensing of human prealbumin. , 2008, Biosensors & bioelectronics.

[7]  D. Pette,et al.  Fast and slow isoforms of troponin I and troponin C. Distribution in normal rabbit muscles and effects of chronic stimulation. , 1990, European journal of biochemistry.

[8]  A. Henderson,et al.  Discordance between results for serum troponin T and troponin I in renal disease. , 1995, Clinical chemistry.

[9]  J. Chang,et al.  High throughput human DNA purification with aminosilanes tailored silica-coated magnetic nanoparticles , 2007 .

[10]  D. Holt,et al.  Markers of myocardial damage. , 1998, Clinical chemistry.

[11]  Il-Hoon Cho,et al.  Immunogold-silver staining-on-a-chip biosensor based on cross-flow chromatography. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[12]  M. Yacoub,et al.  Troponin I gene expression during human cardiac development and in end-stage heart failure. , 1993, Circulation research.

[13]  A. Wu Interpretation of high sensitivity cardiac troponin I results: reference to biological variability in patients who present to the emergency room with chest pain: case report series. , 2009, Clinica chimica acta; international journal of clinical chemistry.

[14]  Joseph Wang,et al.  Metal nanoparticle-based electrochemical stripping potentiometric detection of DNA hybridization. , 2001, Analytical chemistry.

[15]  Il-Hoon Cho,et al.  Chemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatography. , 2009, Analytica chimica acta.

[16]  A. Wu A selected history and future of immunoassay development and applications in clinical chemistry. , 2006, Clinica chimica acta; international journal of clinical chemistry.

[17]  A. Bereznikova,et al.  Utilization of recombinant Fab fragments in a cTnI immunoassay conducted in spot wells. , 2006, Clinical biochemistry.

[18]  Na Li,et al.  Sandwich-type electrochemiluminescence immunosensor based on N-(aminobutyl)-N-ethylisoluminol labeling and gold nanoparticle amplification. , 2009, Talanta.

[19]  Itamar Willner,et al.  A DNAzyme cascade for the amplified detection of Pb(2+) ions or L-histidine. , 2008, Chemical communications.

[20]  J. Lima,et al.  Multi-pumping flow systems: an automation tool. , 2004, Talanta.

[21]  A. Jaffe,et al.  Improved detection of cardiac contusion with cardiac troponin I. , 1996, American heart journal.

[22]  David Juncker,et al.  Simultaneous detection of C-reactive protein and other cardiac markers in human plasma using micromosaic immunoassays and self-regulating microfluidic networks. , 2004, Biosensors & bioelectronics.

[23]  Hans Wolf,et al.  Chemiluminescence multichannel immunosensor for biodetection , 2002 .

[24]  Pamela R. Tsuruda,et al.  5-HT4 receptor agonist mediated enhancement of cognitive function in vivo and amyloid precursor protein processing in vitro: A pharmacodynamic and pharmacokinetic assessment , 2011, Neuropharmacology.

[25]  Sai Bi,et al.  Ultrasensitive enhanced chemiluminescence enzyme immunoassay for the determination of alpha-fetoprotein amplified by double-codified gold nanoparticles labels. , 2009, Biosensors & bioelectronics.

[26]  Youyu Zhang,et al.  Hairpin DNA switch for ultrasensitive spectrophotometric detection of DNA hybridization based on gold nanoparticles and enzyme signal amplification. , 2010, Analytical chemistry.

[27]  B. Godlewska-Żyłkiewicz,et al.  A novel flow-injection method for the determination of Pt(IV) in environmental samples based on chemiluminescence reaction of lucigenin and biosorption. , 2010, Talanta.

[28]  S. Maxwell,et al.  Enhanced chemiluminescent assay for antioxidant capacity in biological fluids , 1992 .

[29]  Itamar Willner,et al.  Following Glucose Oxidase Activity by Chemiluminescence and Chemiluminescence Resonance Energy Transfer (CRET) Processes Involving Enzyme-DNAzyme Conjugates , 2011, Sensors.

[30]  Changchun Liu,et al.  An amperometric glucose biosensor based on a screen-printed electrode and Os-complex mediator for flow injection analysis , 2011 .

[31]  S W Sharkey,et al.  Improved detection of minor ischemic myocardial injury with measurement of serum cardiac troponin I. , 1997, Clinical chemistry.