Sensor-to-body calibration procedure for clinical motion analysis of lower limb using magnetic and inertial measurement units.

Magnetic and Inertial measurement units (MIMUs) have become exceedingly popular for ambulatory human motion analysis during the past two decades. However, measuring anatomically meaningful segment and joint kinematics requires virtual alignment of the MIMU frame with the anatomical frame of its corresponding segment. Therefore, this paper presents a simple calibration procedure, based on MIMU readouts, to align the inertial frame of the MIMU with the anatomical frames, as recommended by ISB. The proposed calibration includes five seconds of quiet standing in a neutral posture followed by ten consecutive hip flexions/extensions. This procedure will independently calibrate MIMUs attached to the pelvis, thigh, shank, and foot. The accuracy and repeatability of the calibration procedure and the 3D joint angle estimation were validated against the gold standard motion capture system by an experimental study with ten able-bodied participants. The procedure showed high test-retest repeatability in aligning the MIMU frame with its corresponding anatomical frame, i.e., the helical angle between the MIMU and anatomical frames did not significantly differ between the test and retest sessions (except for thigh MIMU). Compared to previously introduced procedures, this procedure attained the highest inter-participant repeatability (inter-participant coefficient of variations of the helical angle: 20.5-42.2%). Further, the proposed calibration would reduce the offset errors of the 3D joint angle estimation (up to 12.8 degrees on average) compared to joint angle estimation without calibration (up to 26.3 degrees on average). The proposed calibration enables MIMU to measure clinically meaningful gait kinematics.

[1]  Eduardo Palermo,et al.  Experimental evaluation of accuracy and repeatability of a novel body-to-sensor calibration procedure for inertial sensor-based gait analysis , 2014 .

[2]  Hossein Rouhani,et al.  Detection of daily postures and walking modalities using a single chest-mounted tri-axial accelerometer. , 2018, Medical engineering & physics.

[3]  A Leardini,et al.  Position and orientation in space of bones during movement: anatomical frame definition and determination. , 1995, Clinical biomechanics.

[4]  B M Jolles,et al.  Functional calibration procedure for 3D knee joint angle description using inertial sensors. , 2009, Journal of biomechanics.

[5]  Adriano Ferrari,et al.  ‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors , 2009, Medical & Biological Engineering & Computing.

[6]  A. M. Sabatini,et al.  A novel functional calibration method for real-time elbow joint angles estimation with magnetic-inertial sensors. , 2017, Journal of biomechanics.

[7]  Aurelio Cappozzo,et al.  Joint kinematics estimate using wearable inertial and magnetic sensing modules. , 2008, Gait & posture.

[8]  Christian Larue,et al.  Evaluation of Eight Methods for Aligning Orientation of Two Coordinate Systems. , 2016, Journal of biomechanical engineering.

[9]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[10]  Stefano Paolucci,et al.  Wearable inertial sensors for human movement analysis , 2016, Expert review of medical devices.

[11]  Norbert Schmitz,et al.  Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion , 2017, Sensors.

[12]  P R Cavanagh,et al.  ISB recommendations for standardization in the reporting of kinematic data. , 1995, Journal of biomechanics.

[13]  P H Veltink,et al.  Ambulatory measurement of arm orientation. , 2007, Journal of biomechanics.

[14]  Pietro Picerno,et al.  25 years of lower limb joint kinematics by using inertial and magnetic sensors: A review of methodological approaches. , 2017, Gait & posture.