Longitudinal myocardial peak velocities using high temporal resolution phase-contrast and simple averaging are comparable to tissue Doppler echocardiography

ObjectPhase contrast imaging is widely used to measure blood velocity. However tissue Doppler imaging (TDI) echocardiography is the reference for myocardial velocity assessment. This study aims at validating the ability of phase contrast (PC) sequences to correctly assess myocardial velocities and to compare these velocities to TDI. The phase contrast sequence was performed with breath-hold parameters and with parameters tuned to increase temporal resolution in free breathing.Materials and methodsLeft and Right auriculo-ventricular annuluses longitudinal velocities were recorded on six healthy volunteers with different temporal resolutions (TDI: 5 ms, breath-hold PC: 94 ms and free-breathing PC: 19 ms). Free-breathing PC was obtained by averaging of three excitations. Amplitudes of four standard echocardiographic and clinically relevant myocardial longitudinal velocity waves were compared: Early filling and auricular, systolic and isovolumic contractions.ResultsIsovolumic contraction waves were only visible with free-breathing PC and TDI. The differences with the reference TDI wave velocities were lower (p = 0.02) for free-breathing PC (19.2 ± 2.6 %) than for breath-hold PC (28.1 ± 2.9 %). These differences for free-breathing PC were close to (p = 0.21) the coefficient of variation of the measurements provided by TDI (14.8 ± 1.2 %).ConclusionMyocardial longitudinal peak velocities can be assessed with a PC sequence tuned to optimize temporal resolution.

[1]  J. Chambers,et al.  Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. , 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  S. Solomon,et al.  A clinician's guide to tissue Doppler imaging. , 2006, Circulation.

[3]  Freddy Odille,et al.  Free‐breathing imaging of the heart using 2D cine‐GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function , 2012, Journal of magnetic resonance imaging : JMRI.

[4]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[5]  Arturo Evangelista,et al.  Recommendations for the evaluation of left ventricular diastolic function by echocardiography. , 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[6]  Jürgen Hennig,et al.  Visualization of multidirectional regional left ventricular dynamics by high‐temporal‐resolution tissue phase mapping , 2009, Journal of magnetic resonance imaging : JMRI.

[7]  A. Bornstedt,et al.  Acceleration of tissue phase mapping by k-t BLAST: a detailed analysis of the influence of k-t-BLAST for the quantification of myocardial motion at 3T , 2011, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[8]  Maxim Zaitsev,et al.  Navigator gated high temporal resolution tissue phase mapping of myocardial motion , 2006, Magnetic resonance in medicine.

[9]  A. Fraser,et al.  Reproducibility of pulsed wave tissue Doppler echocardiography. , 1999, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[10]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[11]  Clare Jackson,et al.  Journal of Cardiovascular Magnetic Resonance Open Access Normal Right-and Left Ventricular Volumes and Myocardial Mass in Children Measured by Steady State Free Precession Cardiovascular Magnetic Resonance , 2009 .

[12]  Jürgen Hennig,et al.  Detailed analysis of myocardial motion in volunteers and patients using high‐temporal‐resolution MR tissue phase mapping , 2006, Journal of magnetic resonance imaging : JMRI.

[13]  R J van der Geest,et al.  Right ventricular function in patients after acute myocardial infarction assessed with phase contrast MR velocity mapping encoded in three directions. , 2000, Journal of magnetic resonance imaging : JMRI.

[14]  David Atkinson,et al.  Split‐acquisition real‐time CINE phase‐contrast MR flow measurements , 2010, Magnetic resonance in medicine.

[15]  Jürgen Hennig,et al.  Regional myocardial function with tissue phase mapping , 1998 .

[16]  Volker Rasche,et al.  Combination of tagging and tissue phase mapping to accelerate myocardial motion measurements in three directions , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[17]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[18]  Roger Abächerli,et al.  Noise Cancellation Signal Processing Method and Computer System for Improved Real-Time Electrocardiogram Artifact Correction During MRI Data Acquisition , 2007, IEEE Transactions on Biomedical Engineering.

[19]  Michael Markl,et al.  Measurement of left ventricular velocities: phase contrast MRI velocity mapping versus tissue-doppler-ultrasound in healthy volunteers. , 2004, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[20]  S. Ommen,et al.  Clinical Utility of Doppler Echocardiography and Tissue Doppler Imaging in the Estimation of Left Ventricular Filling Pressures: A Comparative Simultaneous Doppler-Catheterization Study , 2000, Circulation.

[21]  M. Markl,et al.  K‐t GRAPPA accelerated phase contrast MRI: Improved assessment of blood flow and 3‐directional myocardial motion during breath‐hold , 2013, Journal of magnetic resonance imaging : JMRI.

[22]  M. Robson,et al.  Myocardial tissue phase mapping with cine phase-contrast mr imaging: regional wall motion analysis in healthy volunteers. , 2006, Radiology.

[23]  C. Selton-Suty,et al.  Non-invasive investigations of the right heart: how and why? , 2009, Archives of cardiovascular diseases.

[24]  J Hennig,et al.  Phase contrast MRI with improved temporal resolution by view sharing: k-space related velocity mapping properties. , 2001, Magnetic resonance imaging.

[25]  T. Wakatsuki,et al.  Effect of aging on diastolic left ventricular myocardial velocities measured by pulsed tissue Doppler imaging in healthy subjects. , 1999, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[26]  Volker Rasche,et al.  Acceleration of tissue phase mapping with sensitivity encoding at 3T , 2011, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[27]  John N Oshinski,et al.  Three-directional myocardial phase-contrast tissue velocity MR imaging with navigator-echo gating: in vivo and in vitro study. , 2008, Radiology.

[28]  P. Sengupta,et al.  Left ventricular isovolumic flow sequence during sinus and paced rhythms: new insights from use of high-resolution Doppler and ultrasonic digital particle imaging velocimetry. , 2007, Journal of the American College of Cardiology.

[29]  A. DeMaria,et al.  Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography. , 1998, The American journal of cardiology.

[30]  Li Feng,et al.  Accelerated phase‐contrast cine MRI using k‐t SPARSE‐SENSE , 2012, Magnetic resonance in medicine.