Multi transmit beams for fast cardiac imaging towards clinical routine

Multiple-line transmit (MLT) techniques, involving the simultaneous transmission of multiple focused beams into different directions, increase the frame rate without significantly compromising the resolution or contrast. The higher frame rate can facilitate the assessment of regional myocardial deformation or of left ventricular dyssynchrony. However, application in clinical routine is still hindered by the lack of real-time implementations. This paper reports on the first real-time implementation of MLT-based imaging and on a pulse-width modulator for three-level pulsers, so as to transmit complex waveforms like those needed by MLT. Experiments with the ULA-OP 256 research scanner connected to a 128-element phased array probe show that real-time imaging is feasible at up to 212 Hz without significant reduction in image quality or field-of-view, pushing fast MLT cardiac imaging one-step forward to clinical routine.

[1]  Piero Tortoli,et al.  ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[2]  Piero Tortoli,et al.  Multi-Transmit Beam Forming for Fast Cardiac Imaging—Experimental Validation and In Vivo Application , 2014, IEEE Transactions on Medical Imaging.

[3]  Hiroshi Kanai,et al.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming , 2011, Journal of Medical Ultrasonics.

[4]  Steven Freear,et al.  Width-modulated square-wave pulses for ultrasound applications , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[5]  Alessandro Ramalli,et al.  In vitro and in vivo tissue harmonic images obtained with parallel transmit beamforming by means of orthogonal frequency division multiplexing , 2015 .

[6]  A. Drukarev,et al.  Beam transformation techinques for ultrasonic medical imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Andreas Austeng,et al.  Correspondence - Multi-line transmission in medical imaging using the second-harmonic signal , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[8]  Maja Cikes,et al.  Ultrafast cardiac ultrasound imaging: technical principles, applications, and clinical benefits. , 2014, JACC. Cardiovascular imaging.

[9]  Marc D Weinshenker,et al.  Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays. , 1984 .

[10]  Hon Fai Choi,et al.  Comparison of conventional parallel beamforming with plane wave and diverging wave imaging for cardiac applications: a simulation study , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  M. Fink,et al.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  T. Hergum,et al.  Parallel beamforming using synthetic transmit beams [biomedical ultrasound imaging] , 2004, IEEE Ultrasonics Symposium, 2004.

[14]  Raoul Mallart,et al.  Improved imaging rate through simultaneous transmission of several ultrasound beams , 1992, SPIE Optics + Photonics.

[15]  Piero Tortoli,et al.  Wide-Angle Tissue Doppler Imaging at High Frame Rate Using Multi-Line Transmit Beamforming: An Experimental Validation In Vivo , 2016, IEEE Transactions on Medical Imaging.