Modeling the grid synchronization induced negative-resistor-like behavior in the output impedance of a three-phase photovoltaic inverter

Photovoltaic power has to be converted from DC into AC in grid-connected applications. The conversion is done by using a single or three-phase inverter. Phase angle and frequency of the injected current and the grid voltage have to match to achieve unity power factor. This has been commonly accomplished by using a phase-locked-loop (PLL). The PLL has a tendency to make the output impedance of the inverter to appear as a negative resistor which can introduce harmonics in the grid current or even make the inverter-grid interface unstable. This paper presents a general small-signal model of a PV inverter in the synchronous reference frame which includes the PLL. Due to the negative resistance, the inverter can become unstable when the grid has high inductance. The derived small-signal model can be used to predict the exact conditions where the instability will take place by utilizing the impedance ratio and Nyquist stability criterion.

[1]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[2]  Robert Turner,et al.  A Case Study on the Application of the Nyquist Stability Criterion as Applied to Interconnected Loads and Sources on Grids , 2013, IEEE Transactions on Industrial Electronics.

[3]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[4]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[5]  Bo Wen,et al.  Experimental verification of the Generalized Nyquist stability criterion for balanced three-phase ac systems in the presence of constant power loads , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[6]  P.J.M. Heskes,et al.  A method for operational grid and load impedance measurements , 2005, 2005 International Conference on Future Power Systems.

[7]  P.J.M. Heskes,et al.  Harmonic interaction between a large number of distributed power inverters and the distribution network , 2004, IEEE Transactions on Power Electronics.

[8]  Tuomas Messo,et al.  Negative output impedance in three-phase grid-connected renewable energy source inverters based on reduced-order model , 2011 .

[9]  Tuomas Messo,et al.  Determining the Value of DC-Link Capacitance to Ensure Stable Operation of a Three-Phase Photovoltaic Inverter , 2014, IEEE Transactions on Power Electronics.

[10]  Jian Sun,et al.  Impedance shaping of three-phase grid-parallel voltage-source converters , 2012, 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[11]  Jian Sun,et al.  Impedance-Based Stability Criterion for Grid-Connected Inverters , 2011, IEEE Transactions on Power Electronics.

[12]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[13]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[14]  Jian Sun,et al.  Modeling and mitigation of harmonic resonance between wind turbines and the grid , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[15]  D. Boroyevich,et al.  Frequency behavior and its stability of grid-interface converter in distributed generation systems , 2012, 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[16]  Hans-Peter Nee,et al.  Power-Synchronization Control of Grid-Connected Voltage-Source Converters , 2010, IEEE Transactions on Power Systems.