Radiological properties of normoxic polymer gel dosimeters.

The radiological properties of the normoxic polymer gel dosimeters MAGIC, MAGAS, and MAGAT [methacrylic and ascorbic acid in gelatin initiated by copper; methacrylic acid gelatine gel with ascorbic acid; and methacrylic acid gelatine and tetrakis (hydroxymethyl) phosphonium chloride, respectively] have been investigated. The radiological water equivalence was determined by comparing the polymer gel macroscopic photon and electron interaction cross sections over the energy range from 10 keV to 20 MeV and by Monte Carlo modeling of depth doses. Normoxic polymer gel dosimeters have a high gelatine and monomer concentration and therefore mass density (kg m(-3)) up to 3.8% higher than water. This results in differences between the cross-section ratios of the normoxic polymer gels and water of up to 3% for the attenuation, energy absorption, and collision stopping power coefficient ratios through the Compton dominant energy range. The mass cross-section ratios were within 2% of water except for the mass attenuation and energy absorption coefficients ratios, which showed differences with water of up to 6% for energies less than 100 keV. Monte Carlo modeling was undertaken for the polymer gel dosimeters to model the electron and photon transport resulting from a 6 MV photon beam. The absolute percentage differences between gel and water were within 1% and the relative percentage differences were within 3.5%. The results show that the MAGAT gel formulation is the most radiological water equivalent of the normoxic polymer gel dosimeters investigated due to its lower mass density measurement compared with MAGAS and MAGIC gels.

[1]  H. E. Johns,et al.  Physics of Radiology , 1983 .

[2]  P Keall,et al.  A theoretical study of the radiological properties and water equivalence of Fricke and polymer gels used for radiation dosimetry. , 1999, Australasian physical & engineering sciences in medicine.

[3]  T Kron,et al.  Investigation of the tissue equivalence of gels used for NMR dosimetry. , 1993, Physics in medicine and biology.

[4]  C Baldock,et al.  A basic study of some normoxic polymer gel dosimeters. , 2002, Physics in medicine and biology.

[5]  C Baldock,et al.  Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry. , 1998, Physics in medicine and biology.

[6]  J. H. Hubbell,et al.  Photon mass attenuation and energy-absorption coefficients , 1982 .

[7]  M. Mather,et al.  Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters. , 2002, Physics in medicine and biology.

[8]  R. Mohan,et al.  A Monte Carlo study of radiation transport through multileaf collimators. , 2001, Medical physics.

[9]  J. Gore,et al.  Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. , 2001, Physics in medicine and biology.

[10]  C Baldock,et al.  Attenuation of diagnostic energy photons by polymer gel dosimeters. , 2002, Physics in medicine and biology.

[11]  P. Andreo Monte Carlo techniques in medical radiation physics. , 1991, Physics in medicine and biology.

[12]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .

[13]  C. Baldock,et al.  Experimental study of attenuation properties of normoxic polymer gel dosimeters. , 2004, Physics in medicine and biology.

[14]  Christodoulos Constantinou,et al.  Tissue substitutes for particulate radiations and their use in radiation dosimetry and radiotherapy , 1978 .

[15]  Clive Baldock,et al.  Proceedings of DOSGEL 2004: Third International Conference on Radiotherapy Gel Dosimetry , 2004 .

[16]  L. Olsson,et al.  A new dosimeter based on ferrous sulphate solution and agarose gel , 1991 .

[17]  C Baldock,et al.  Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters. , 2002, Physics in medicine and biology.

[18]  D. R. White,et al.  Tissue substitutes in experimental radiation physics. , 1978, Medical physics.

[19]  J. Gore,et al.  Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging. , 1984, Physics in medicine and biology.