Preliminary evaluation of multifield and single-field optimization for the treatment planning of spot-scanning proton therapy of head and neck cancer.
暂无分享,去创建一个
Wei Liu | Steven J Frank | Radhe Mohan | Xiaodong Zhang | Richard Wu | Yupeng Li | R. Mohan | Xiaodong Zhang | X. Zhu | E. Quan | Yupeng Li | S. Frank | X Ronald Zhu | Enzhuo M Quan | R. Wu | Wei Liu | X. R. Zhu | Steven J. Frank
[1] A. Pérez-Andújar,et al. Neutron production from beam-modifying devices in a modern double scattering proton therapy beam delivery system , 2009, Physics in medicine and biology.
[2] R. Mohan,et al. Adjustment of the lateral and longitudinal size of scanned proton beam spots using a pre-absorber to optimize penumbrae and delivery efficiency , 2010, Physics in medicine and biology.
[3] Wei Liu,et al. TH‐C‐BRB‐01: Toward a thorough Evaluation of IMPT Plan Sensitivity to Uncertainties: Revisit the Worst‐Case Analysis with An Exhaustively Sampling Approach , 2011 .
[4] Thomas Bortfeld,et al. Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning. , 2008, Medical physics.
[5] E. Pedroni,et al. Intensity modulated proton therapy: a clinical example. , 2001, Medical physics.
[6] Radhe Mohan,et al. Robust optimization of intensity modulated proton therapy. , 2012, Medical physics.
[7] O. Zeidan,et al. Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams. , 2012, Medical physics.
[8] Nobuyuki Kanematsu,et al. A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coverage , 2011, Physics in medicine and biology.
[9] Wei Liu,et al. Influence of robust optimization in intensity-modulated proton therapy with different dose delivery techniques. , 2012, Medical physics.
[10] Anders Forsgren,et al. Minimax optimization for handling range and setup uncertainties in proton therapy. , 2011, Medical physics.
[11] Uwe Titt,et al. Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston. , 2009, Medical physics.
[12] A. Lomax,et al. Intensity modulation methods for proton radiotherapy. , 1999, Physics in medicine and biology.
[13] Bijan Arjomandy,et al. Patient-specific quality assurance for prostate cancer patients receiving spot scanning proton therapy using single-field uniform dose. , 2011, International journal of radiation oncology, biology, physics.