Impact of Shunt-FACTS on Distance Protection of Transmission Lines

This paper presents the performance of distance protection of transmission lines when compensated with shunt flexible AC transmission system (FACTS) controllers/devices. The performance of distance protection is evaluated for shunt-FACTS controllers applied for mid-point voltage control. The impact of two types of shunt FACTS controllers, static VAr compensators (SVC) and static synchronous compensators (STATCOM) on the transmission line distance protection are studied for different fault types, fault locations and system conditions. The dynamics of the shunt-FACTS controllers with their associated control systems are considered and simulated using RSCAD/RTDS testing environment. The performance of both the basic/non-pilot distance scheme and a directional comparison blocking (DCB) scheme are evaluated in this paper. The results of the commercial relay testing show the adverse effects of mid-point shunt-FACTS compensation of transmission line on both non-pilot and DCB distance protection schemes

[1]  Yin Xianggen,et al.  The impact of TCSC on distance protection relay , 1998, POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151).

[2]  Ganapati Panda,et al.  Digital protection of power transmission lines in the presence of series connected FACTS devices , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[3]  G. Joos,et al.  Operation of Impedance Protection Relays with the STATCOm , 2002, IEEE Power Engineering Review.

[4]  E. J. Stacey,et al.  UPFC-unified power flow controller: theory, modeling, and applications , 1998 .

[5]  Rajiv K. Varma,et al.  Thyristor-Based Facts Controllers for Electrical Transmission Systems , 2002 .

[6]  Bernhard Bachmann,et al.  Application of artificial neural networks for series compensated line protection , 1996, Proceedings of International Conference on Intelligent System Application to Power Systems.

[7]  Mojtaba Khederzadeh The impact of FACTS device on digital multifunctional protective relays , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[8]  Stephen A. Sebo,et al.  Thyristor-Based FACTS Controllers for Electrical Transmission Systems , 2002 .

[9]  Damir Novosel,et al.  Problems and solutions for microprocessor protection of series compensated lines , 1997 .

[10]  T.S. Sidhu,et al.  Performance of distance relays on shunt-FACTS compensated transmission lines , 2005, IEEE Transactions on Power Delivery.