PET/MR Synchronization by Detection of Switching Gradients

The full potential of simultaneous Positron Emission Tomography (PET) and Magnetic Resonance Imaging (MRI) acquisition, such as dynamic studies or motion compensation, can only be explored if the data of both modalities is temporally synchronized. As such hybrid imaging systems are commonly realized as custom-made PET inserts for commercially available MRI scanner, a synchronization solution has to be implemented (depending on the vendor of the MRI system). In contrast, we demonstrate a simple method for temporal synchronization, which does not require a connection to the MRI. It uses the normally undesired effect of induced voltages on the PET electronics from switching MRI gradients. The electronic circuit needs very few components and the gradient pick-up coils are made from PCB traces and vias on the PET detector boards. Neither programming the MRI nor any physical connection to the MR scanner is needed, thus avoiding electromagnetic compatibility problems. This method works inherently with most MRI sequences and is a vendor- independent solution. A characterization of the sensors in an MRI scanner showed that the MRI gradients are detected with a precision of $120~\mu\hbox{s}$ (with the current implementation). Using different trigger thresholds, it is possible to trigger selectively on certain MRI sequences, depending on their gradient slew rate settings. Timings and pulse diagrams of MRI sequences can be recognized from the generated data. The method was successfully used for temporal alignment between PET and MRI in an MRI-based PET-motion-compensation application.

[1]  Nadim Joni Shah,et al.  Analysis and Correction of Count Rate Reduction During Simultaneous MR-PET Measurements With the BrainPET Scanner , 2012, IEEE Transactions on Medical Imaging.

[2]  René M. Botnar,et al.  A Digital Preclinical PET/MRI Insert and Initial Results , 2015, IEEE Transactions on Medical Imaging.

[3]  Martin S Judenhofer,et al.  Applications for preclinical PET/MRI. , 2013, Seminars in nuclear medicine.

[4]  Michael Garwood,et al.  Fast and quiet MRI using a swept radiofrequency. , 2006, Journal of magnetic resonance.

[5]  J. E. Mackewn,et al.  PVA Cryogel for Construction of Deformable PET-MR Visible Phantoms , 2013, IEEE Transactions on Nuclear Science.

[6]  T Schaeffter,et al.  Fast generation of 4D PET-MR data from real dynamic MR acquisitions , 2011, Physics in medicine and biology.

[7]  N. Schwenzer,et al.  Respiratory Motion Correction in Oncologic PET Using T1-Weighted MR Imaging on a Simultaneous Whole-Body PET/MR System , 2013, The Journal of Nuclear Medicine.

[8]  Volkmar Schulz,et al.  An MR-compatible singles detection and processing unit for simultaneous preclinical PET/MR , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[9]  C. Tsoumpas,et al.  STIR: software for tomographic image reconstruction release 2 , 2012, 2006 IEEE Nuclear Science Symposium Conference Record.

[10]  Volkmar Schulz,et al.  Gradient transparent RF housing for simultaneous PET/MRI using carbon fiber composites , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[11]  Markus Henningsson,et al.  A new framework for interleaved scanning in cardiovascular MR: Application to image‐based respiratory motion correction in coronary MR angiography , 2015, Magnetic resonance in medicine.

[12]  Ciprian Catana,et al.  MRI-Assisted PET Motion Correction for Neurologic Studies in an Integrated MR-PET Scanner , 2011, The Journal of Nuclear Medicine.

[13]  Volkmar Schulz,et al.  Demonstration of motion correction for PET-MR with PVA cryogel phantoms , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[14]  Volkmar Schulz,et al.  FPGA-based singles and coincidences processing pipeline for integrated digital PET/MR detectors , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[15]  V. Schulz,et al.  PET/MRI insert using digital SiPMs: Investigation of MR-compatibility , 2014, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[16]  Volkmar Schulz,et al.  Design concept of world's first preclinical PET/MR insert with fully digital silicon photomultiplier technology , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[17]  P Gebhardt,et al.  MR-compatibility assessment of the first preclinical PET-MRI insert equipped with digital silicon photomultipliers , 2015, Physics in medicine and biology.

[18]  Volkmar Schulz,et al.  PET performance evaluation of a pre-clinical SiPM based MR-compatible PET scanner , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[19]  Volkmar Schulz,et al.  MR compatibility aspects of a silicon photomultiplier-based PET/RF insert with integrated digitisation , 2014, Physics in medicine and biology.