CT technology overview: 64-slice and beyond.

Sixty-four-slice CT typified the dramatic race in technical development in radiology. Featuring high spatial resolution with 0.5-mm thin slices and 0.3-second gantry revolution times, it has become state-of-the-art technology in CT imaging shortly after its clinical introduction. Three-dimensional tube modulation together with adaptive x-ray shutters led to significant dose reduction to the patients while improving image quality because of implementation of optimized reconstruction algorithms. The latest innovations-new detector materials, dual-layer detector, dual-source and dynamic volume CT-represent the pinnacles in CT imaging, pursuing different directions to further clinical applications of CT.

[1]  Jiang Hsieh,et al.  Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. , 2006, Medical physics.

[2]  Borut Marincek,et al.  Dual-Energy Contrast-Enhanced Computed Tomography for the Detection of Urinary Stone Disease , 2007, Investigative radiology.

[3]  M. Reiser,et al.  New applications for noninvasive cardiac imaging: dual-source computed tomography , 2007, European radiology.

[4]  J. Rumberger,et al.  Ultrafast cardiac CT scanning. , 1989, Cardiology clinics.

[5]  P. Rogalla,et al.  [Spatial and temporal resolution with 16-slice computed tomography for cardiac imaging]. , 2003, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[6]  K. Taguchi,et al.  Algorithm for image reconstruction in multi-slice helical CT. , 1998, Medical physics.

[7]  Marc Kachelrieß,et al.  Advanced single-slice rebinning in cone-beam spiral CT: theoretical considerations and medical applications , 2000, Image Processing.

[8]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[9]  I. Mori Antialiasing backprojection for helical MDCT. , 2008, Medical physics.

[10]  G N Hounsfield,et al.  The E.M.I. scanner , 1977, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[11]  G. Hounsfield Computerized transverse axial scanning (tomography): Part I. Description of system. 1973. , 1973, The British journal of radiology.

[12]  Michael Knaup,et al.  Impact of the z-flying focal spot on resolution and artifact behavior for a 64-slice spiral CT scanner , 2006, European Radiology.

[13]  R. P. Parker,et al.  Tissue analysis by dual-energy computed tomography. , 1986, The British journal of radiology.

[14]  A M Cormack 75 Years of Radon Transform , 1992, Journal of computer assisted tomography.

[15]  W A Kalender,et al.  Advanced single-slice rebinning for tilted spiral cone-beam CT. , 2001, Medical physics.

[16]  B. Hamm,et al.  Evaluation of Left and Right Ventricular Diastolic Function by Electron-beam Computed Tomography in Patients With Passive Epicardial Constraint , 2008, Journal of computer assisted tomography.

[17]  S. Leng,et al.  Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector , 2005, Physics in medicine and biology.

[18]  U. Hoffmann,et al.  Acute myocardial ischemia after aortic valve replacement: a comprehensive diagnostic evaluation using dynamic multislice spiral computed tomography. , 2006, European journal of radiology.

[19]  Shuhei Komatsu,et al.  A combination-weighted Feldkamp-based reconstruction algorithm for cone-beam CT , 2006, Physics in medicine and biology.

[20]  Willi A Kalender,et al.  Intensity distribution and impact of scatter for dual-source CT , 2007, Physics in medicine and biology.

[21]  H. Otero,et al.  Initial evaluation of coronary images from 320-detector row computed tomography , 2008, The International Journal of Cardiovascular Imaging.